Z. Arslan, Huri Yeşildal, Enes Malik Akdas, Merve Yazıcı Kara, S. Balcı
{"title":"LMA保护器和Baska面罩在逆行输尿管镜手术中的比较:一项前瞻性随机临床研究","authors":"Z. Arslan, Huri Yeşildal, Enes Malik Akdas, Merve Yazıcı Kara, S. Balcı","doi":"10.5336/anesthe.2022-94932","DOIUrl":null,"url":null,"abstract":"ABS TRACT Objective: The Baska and the Protector Laryngeal masks are single-use second-generation supraglottic airway devices with a dual gastric channel. Material and Methods: 64 American Society of Anesthesiologists physical status 1-2 patients between the ages of 18-70 undergoing retrograde ureteroscopic surgery enrolled in this prospective randomized study. Results: Demographic airway variables and airway characteristics were similar between the groups. Insertion time was shorter in the Baska mask group [14 (11-20) versus 20 (13-27) seconds, p=0.035]. The need for optimization maneuvers during insertion was higher for the Baska mask group (p=0.009). The laryngeal mask airway (LMA) insertion was easier in the LMA Protector group (p=0.023). The first insertion success rate was 75% for the LMA Protector and 84% in the Baska mask. The total success rate of both devices was 91%. Nasogastric tube insertion was faster in the Baska mask group [14 (12-15) versus 17 (13-25) seconds; p=0.003]. Fiberoptic views were similar between the groups. Minute volume after insertion of the device was higher in the LMA Protector group [8 (6.5-10) L/min versus 6 (5-7) L/min; p<0.001]. Expiratory tidal volume was higher in the LMA Protector group after insertion of the device, 15 minutes, 30 minutes, and 45 minutes after insertion (p<0.001, p=0.032, p=0.001, p=0.027 respectively). The end-tidal sevoflurane concentration (ETsevo) 30 minutes after device insertion was higher in the Baska mask group (1.49±0.38 vs 1.75±0.36; p=0.014). Conclusion: The LMA Protector is superior to the Baska mask in providing higher tidal volumes and decreased need for optimization maneuvers in retrograde ureteroscopic surgery.","PeriodicalId":23442,"journal":{"name":"Turkiye Klinikleri Journal of Anesthesiology Reanimation","volume":"48 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of the LMA Protector and the Baska Mask in Retrograde Ureteroscopic Surgery: A Prospective Randomized Clinical Study\",\"authors\":\"Z. Arslan, Huri Yeşildal, Enes Malik Akdas, Merve Yazıcı Kara, S. Balcı\",\"doi\":\"10.5336/anesthe.2022-94932\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABS TRACT Objective: The Baska and the Protector Laryngeal masks are single-use second-generation supraglottic airway devices with a dual gastric channel. Material and Methods: 64 American Society of Anesthesiologists physical status 1-2 patients between the ages of 18-70 undergoing retrograde ureteroscopic surgery enrolled in this prospective randomized study. Results: Demographic airway variables and airway characteristics were similar between the groups. Insertion time was shorter in the Baska mask group [14 (11-20) versus 20 (13-27) seconds, p=0.035]. The need for optimization maneuvers during insertion was higher for the Baska mask group (p=0.009). The laryngeal mask airway (LMA) insertion was easier in the LMA Protector group (p=0.023). The first insertion success rate was 75% for the LMA Protector and 84% in the Baska mask. The total success rate of both devices was 91%. Nasogastric tube insertion was faster in the Baska mask group [14 (12-15) versus 17 (13-25) seconds; p=0.003]. Fiberoptic views were similar between the groups. Minute volume after insertion of the device was higher in the LMA Protector group [8 (6.5-10) L/min versus 6 (5-7) L/min; p<0.001]. Expiratory tidal volume was higher in the LMA Protector group after insertion of the device, 15 minutes, 30 minutes, and 45 minutes after insertion (p<0.001, p=0.032, p=0.001, p=0.027 respectively). The end-tidal sevoflurane concentration (ETsevo) 30 minutes after device insertion was higher in the Baska mask group (1.49±0.38 vs 1.75±0.36; p=0.014). Conclusion: The LMA Protector is superior to the Baska mask in providing higher tidal volumes and decreased need for optimization maneuvers in retrograde ureteroscopic surgery.\",\"PeriodicalId\":23442,\"journal\":{\"name\":\"Turkiye Klinikleri Journal of Anesthesiology Reanimation\",\"volume\":\"48 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkiye Klinikleri Journal of Anesthesiology Reanimation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5336/anesthe.2022-94932\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkiye Klinikleri Journal of Anesthesiology Reanimation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5336/anesthe.2022-94932","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
目的:Baska和Protector喉罩是具有双胃通道的第二代声门上气道装置。材料和方法:64名美国麻醉医师协会的身体状况1-2名年龄在18-70岁之间接受逆行输尿管镜手术的患者加入了这项前瞻性随机研究。结果:两组间气道人口学变量和气道特征相似。Baska面罩组插入时间较短[14 (11-20)vs 20(13-27)秒,p=0.035]。Baska面罩组在插入时对优化操作的需求更高(p=0.009)。喉罩保护器组更容易插入喉罩气道(LMA) (p=0.023)。LMA保护器的首次插入成功率为75%,Baska面罩的首次插入成功率为84%。两种设备的总成功率为91%。Baska面罩组鼻胃管插入速度更快[14(12-15)秒比17(13-25)秒;p = 0.003)。两组间的光纤图像相似。LMA保护器组插入装置后的分钟体积更高[8 (6.5-10)L/min vs 6 (5-7) L/min;p < 0.001)。LMA保护器组呼气潮气量在插入装置后15分钟、30分钟、45分钟较高(p<0.001, p=0.032, p=0.001, p=0.027)。Baska面罩组在装置插入后30分钟的潮末七氟醚浓度(ETsevo)较高(1.49±0.38 vs 1.75±0.36;p = 0.014)。结论:在逆行输尿管镜手术中,LMA保护器在提供更高的潮汐容量和减少优化操作需求方面优于Baska面罩。
Comparison of the LMA Protector and the Baska Mask in Retrograde Ureteroscopic Surgery: A Prospective Randomized Clinical Study
ABS TRACT Objective: The Baska and the Protector Laryngeal masks are single-use second-generation supraglottic airway devices with a dual gastric channel. Material and Methods: 64 American Society of Anesthesiologists physical status 1-2 patients between the ages of 18-70 undergoing retrograde ureteroscopic surgery enrolled in this prospective randomized study. Results: Demographic airway variables and airway characteristics were similar between the groups. Insertion time was shorter in the Baska mask group [14 (11-20) versus 20 (13-27) seconds, p=0.035]. The need for optimization maneuvers during insertion was higher for the Baska mask group (p=0.009). The laryngeal mask airway (LMA) insertion was easier in the LMA Protector group (p=0.023). The first insertion success rate was 75% for the LMA Protector and 84% in the Baska mask. The total success rate of both devices was 91%. Nasogastric tube insertion was faster in the Baska mask group [14 (12-15) versus 17 (13-25) seconds; p=0.003]. Fiberoptic views were similar between the groups. Minute volume after insertion of the device was higher in the LMA Protector group [8 (6.5-10) L/min versus 6 (5-7) L/min; p<0.001]. Expiratory tidal volume was higher in the LMA Protector group after insertion of the device, 15 minutes, 30 minutes, and 45 minutes after insertion (p<0.001, p=0.032, p=0.001, p=0.027 respectively). The end-tidal sevoflurane concentration (ETsevo) 30 minutes after device insertion was higher in the Baska mask group (1.49±0.38 vs 1.75±0.36; p=0.014). Conclusion: The LMA Protector is superior to the Baska mask in providing higher tidal volumes and decreased need for optimization maneuvers in retrograde ureteroscopic surgery.