氨氯地平和培哚普利原料药剂型质量评价方法的建立与验证

M. V. Ramana, V. Sowmya, K. Sangeetha, K. Nagapreethi, M. Mounika, S. Divya, A. Kanakalaxmi
{"title":"氨氯地平和培哚普利原料药剂型质量评价方法的建立与验证","authors":"M. V. Ramana, V. Sowmya, K. Sangeetha, K. Nagapreethi, M. Mounika, S. Divya, A. Kanakalaxmi","doi":"10.52711/0975-4377.2022.00047","DOIUrl":null,"url":null,"abstract":"Literature survey reveals that few spectrophotometric, high performance liquid chromatographic (HPLC)and High performance thin layer chromatographic (HPTLC)methods were reported for the estimation of Amlodipine and perindopril in bulk and combined pharmaceutical dosage forms. But there is no any stability indicating high performance liquid chromatography study is reported for amlodipine. So the present study was aimed to development of simple, accurate, rapid and economical HPLC stability indicating assay method were established for the determination of Amlodipine and Peridopril in bulk and tablet dosage form. A High-performance liquid chromatograph WATERS, software: Empower 2,2695 separation module, 996 PDA detector, using Phenomenex Luna C18 (4.6mm×250mm) 5µm or equivalent column, with mobile phase composition of Methanol: Phosphate Buffer pH3.0 (70:30v/v) was used. The flow rate of 1.0ml min-1 and effluent was detected at 230nm. The retention time of Amlodipine and Perindopril was found to be 1.870min and 2.499minutes respectively. Linearity was observed over concentration range of 10-50µg ml-1 for Amlodipine and 16-80µg ml-1 for Perindopril respectively. The accuracy of the proposed method was determined by recovery studies and the Amlodipine was found to be 99.1% and Perindopril was found to be 98.8% respectively. The proposed method is applicable to routine analysis of Amlodipine and Perindopril in bulk and pharmaceutical formulations. The proposed method was validated for various ICH parameters like linearity, limit of detection, limits of quantification, accuracy, precision, range and specificity.","PeriodicalId":20963,"journal":{"name":"Research Journal of Pharmaceutical Dosage Forms and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Method Development and Validation for the estimation of Amlodipine and Perindopril in Bulk and Pharmaceutical Dosage Form\",\"authors\":\"M. V. Ramana, V. Sowmya, K. Sangeetha, K. Nagapreethi, M. Mounika, S. Divya, A. Kanakalaxmi\",\"doi\":\"10.52711/0975-4377.2022.00047\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Literature survey reveals that few spectrophotometric, high performance liquid chromatographic (HPLC)and High performance thin layer chromatographic (HPTLC)methods were reported for the estimation of Amlodipine and perindopril in bulk and combined pharmaceutical dosage forms. But there is no any stability indicating high performance liquid chromatography study is reported for amlodipine. So the present study was aimed to development of simple, accurate, rapid and economical HPLC stability indicating assay method were established for the determination of Amlodipine and Peridopril in bulk and tablet dosage form. A High-performance liquid chromatograph WATERS, software: Empower 2,2695 separation module, 996 PDA detector, using Phenomenex Luna C18 (4.6mm×250mm) 5µm or equivalent column, with mobile phase composition of Methanol: Phosphate Buffer pH3.0 (70:30v/v) was used. The flow rate of 1.0ml min-1 and effluent was detected at 230nm. The retention time of Amlodipine and Perindopril was found to be 1.870min and 2.499minutes respectively. Linearity was observed over concentration range of 10-50µg ml-1 for Amlodipine and 16-80µg ml-1 for Perindopril respectively. The accuracy of the proposed method was determined by recovery studies and the Amlodipine was found to be 99.1% and Perindopril was found to be 98.8% respectively. The proposed method is applicable to routine analysis of Amlodipine and Perindopril in bulk and pharmaceutical formulations. The proposed method was validated for various ICH parameters like linearity, limit of detection, limits of quantification, accuracy, precision, range and specificity.\",\"PeriodicalId\":20963,\"journal\":{\"name\":\"Research Journal of Pharmaceutical Dosage Forms and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Research Journal of Pharmaceutical Dosage Forms and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52711/0975-4377.2022.00047\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research Journal of Pharmaceutical Dosage Forms and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52711/0975-4377.2022.00047","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

文献调查显示,分光光度法、高效液相色谱法和高效薄层色谱法用于氨氯地平和培哚普利原料药和复方药的含量测定的文献很少。但目前尚无高效液相色谱法研究氨氯地平的稳定性。因此,本研究旨在建立一种简便、准确、快速、经济的高效液相色谱法测定氨氯地平和培立多普利原料药和片剂含量的稳定性指示法。高效液相色谱仪WATERS,软件:Empower 2,2695分离模块,996 PDA检测器,色谱柱为Phenomenex Luna C18 (4.6mm×250mm) 5µm或同等柱,流动相为甲醇:磷酸缓冲液pH3.0 (70:30v/v)。流速1.0ml min-1,在230nm处检测流出物。氨氯地平和培哚普利的滞留时间分别为1.870min和2.499min。氨氯地平和培哚普利分别在10 ~ 50µg ml-1和16 ~ 80µg ml-1浓度范围内呈线性关系。结果表明,氨氯地平的回收率为99.1%,培哚普利的回收率为98.8%。本方法适用于原料药和制剂中氨氯地平和培哚普利的常规分析。该方法对ICH的线性、检出限、定量限、准确度、精密度、范围和特异性等参数进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Method Development and Validation for the estimation of Amlodipine and Perindopril in Bulk and Pharmaceutical Dosage Form
Literature survey reveals that few spectrophotometric, high performance liquid chromatographic (HPLC)and High performance thin layer chromatographic (HPTLC)methods were reported for the estimation of Amlodipine and perindopril in bulk and combined pharmaceutical dosage forms. But there is no any stability indicating high performance liquid chromatography study is reported for amlodipine. So the present study was aimed to development of simple, accurate, rapid and economical HPLC stability indicating assay method were established for the determination of Amlodipine and Peridopril in bulk and tablet dosage form. A High-performance liquid chromatograph WATERS, software: Empower 2,2695 separation module, 996 PDA detector, using Phenomenex Luna C18 (4.6mm×250mm) 5µm or equivalent column, with mobile phase composition of Methanol: Phosphate Buffer pH3.0 (70:30v/v) was used. The flow rate of 1.0ml min-1 and effluent was detected at 230nm. The retention time of Amlodipine and Perindopril was found to be 1.870min and 2.499minutes respectively. Linearity was observed over concentration range of 10-50µg ml-1 for Amlodipine and 16-80µg ml-1 for Perindopril respectively. The accuracy of the proposed method was determined by recovery studies and the Amlodipine was found to be 99.1% and Perindopril was found to be 98.8% respectively. The proposed method is applicable to routine analysis of Amlodipine and Perindopril in bulk and pharmaceutical formulations. The proposed method was validated for various ICH parameters like linearity, limit of detection, limits of quantification, accuracy, precision, range and specificity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Formulation and Evaluation of Extended Release Oral Suspension of Metformin Hydrochloride Nano Sponge: An Emerging Nano-Technology Based Drug Delivery System Formulation and Evaluation of Herbal Toothpaste Advancing Therapeutics with Liposomal Drug Design: Harnessing the Potential of Liposomes for Targeted Drug Delivery Review on Orodispersible Tablet
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1