{"title":"高通量流动注射分析- mrm3 (FIA-MRM3)光谱法用于马来西亚法医毒理学案件中血液中异构体甲基苯丙胺和芬特明的替代快速筛选","authors":"Fathiah A Zubaidi, Fathiah A Zubaidi, Y. Choo, G. Tan, P. Myron, C. CornelIa","doi":"10.1177/2397847319831368","DOIUrl":null,"url":null,"abstract":"Background: Methamphetamine (MA) and phentermine (PTM) are critical isomeric compounds that often coexist in biological specimen in toxicology cases which have similar nominal mass. The dependency of high-resolution mass spectrometer and special chiral stationary phase column for separation of isomeric compound impedes screening throughput especially in meeting high sampling demand. Aim: In the absence of such equipment for identification, we introduce the flow injection analysis (FIA)-MRM3 technique and demonstrated its capabilities for quick identification of both isomeric compounds without liquid chromatography (LC) separation through the addition of selectivity criteria in the MRM3 mode. Method: 20 to 100 ng/mL of MA and PTM, respectively, in whole blood sample (WBS) and dried blood stain (DBS) were used to develop the method for the identification and relative quantification. Twenty whole blood samples which were reported positive of the drugs were randomly selected and were individually stained onto the Flinders Technology Associates (FTA) card for DBS study. Results: The peaks from the two isomeric compounds were successfully discerned for all the tested specimens using the FIA-MRM3 spectrometry technique. The limit of detection (LOD) and limit of quantification (LOQ) for MA and PTM were comparable to normal liquid chromatography-tandem mass spectrometry runs at 2.23 and 2.07 ng/mL, respectively, for WBS (n = 30). For DBS, the LOD and LOQ were 3.40 and 2.86 ng/mL, respectively. The accuracy and inter-day precision for DBS and WBS were in the range of 99.97–111.19% and 7.17–9.55%, respectively. Conclusion: These results demonstrated that the technique is highly adoptable in the screening of isomeric compounds of similar masses in a simple and rapid analysis.","PeriodicalId":23155,"journal":{"name":"Toxicology Research and Application","volume":"27 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"High-throughput flow injection analysis-MRM3 (FIA-MRM3) spectrometry for alternative fast screening of the isomeric methamphetamine and phentermine in blood for forensic toxicology cases in Malaysia\",\"authors\":\"Fathiah A Zubaidi, Fathiah A Zubaidi, Y. Choo, G. Tan, P. Myron, C. CornelIa\",\"doi\":\"10.1177/2397847319831368\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Methamphetamine (MA) and phentermine (PTM) are critical isomeric compounds that often coexist in biological specimen in toxicology cases which have similar nominal mass. The dependency of high-resolution mass spectrometer and special chiral stationary phase column for separation of isomeric compound impedes screening throughput especially in meeting high sampling demand. Aim: In the absence of such equipment for identification, we introduce the flow injection analysis (FIA)-MRM3 technique and demonstrated its capabilities for quick identification of both isomeric compounds without liquid chromatography (LC) separation through the addition of selectivity criteria in the MRM3 mode. Method: 20 to 100 ng/mL of MA and PTM, respectively, in whole blood sample (WBS) and dried blood stain (DBS) were used to develop the method for the identification and relative quantification. Twenty whole blood samples which were reported positive of the drugs were randomly selected and were individually stained onto the Flinders Technology Associates (FTA) card for DBS study. Results: The peaks from the two isomeric compounds were successfully discerned for all the tested specimens using the FIA-MRM3 spectrometry technique. The limit of detection (LOD) and limit of quantification (LOQ) for MA and PTM were comparable to normal liquid chromatography-tandem mass spectrometry runs at 2.23 and 2.07 ng/mL, respectively, for WBS (n = 30). For DBS, the LOD and LOQ were 3.40 and 2.86 ng/mL, respectively. The accuracy and inter-day precision for DBS and WBS were in the range of 99.97–111.19% and 7.17–9.55%, respectively. Conclusion: These results demonstrated that the technique is highly adoptable in the screening of isomeric compounds of similar masses in a simple and rapid analysis.\",\"PeriodicalId\":23155,\"journal\":{\"name\":\"Toxicology Research and Application\",\"volume\":\"27 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Toxicology Research and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/2397847319831368\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Toxicology Research and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/2397847319831368","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

背景:甲基苯丙胺(Methamphetamine, MA)和芬特明(phentermine, PTM)是两种重要的同分异构体化合物,在毒理学案例中经常共存于具有相似标称质量的生物标本中。高分辨率质谱仪和专用的手性固定相柱对异构化合物分离的依赖影响了筛选的通量,特别是在满足高采样要求时。目的:在缺乏此类鉴定设备的情况下,我们引入了流动注射分析(FIA)-MRM3技术,并通过在MRM3模式中添加选择性标准,证明了其无需液相色谱(LC)分离即可快速鉴定两种异构体化合物的能力。方法:采用全血样品(WBS)和干血染色(DBS)中分别加入20 ~ 100 ng/mL的MA和PTM,建立鉴定和相对定量方法。随机抽取20份报告药物阳性的全血样本,分别染色到弗林德斯技术协会(FTA)卡片上进行DBS研究。结果:采用FIA-MRM3光谱分析技术,两种同分异构体化合物的峰均被成功识别。MA和PTM的检出限(LOD)和定量限(LOQ)与常规液相色谱-串联质谱法相当,WBS (n = 30)的检出限分别为2.23和2.07 ng/mL。DBS的LOD和LOQ分别为3.40和2.86 ng/mL。DBS和WBS的准确度和日间精密度分别为99.97 ~ 111.19%和7.17 ~ 9.55%。结论:该方法可快速、简便地筛选质量相近的同分异构体化合物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High-throughput flow injection analysis-MRM3 (FIA-MRM3) spectrometry for alternative fast screening of the isomeric methamphetamine and phentermine in blood for forensic toxicology cases in Malaysia
Background: Methamphetamine (MA) and phentermine (PTM) are critical isomeric compounds that often coexist in biological specimen in toxicology cases which have similar nominal mass. The dependency of high-resolution mass spectrometer and special chiral stationary phase column for separation of isomeric compound impedes screening throughput especially in meeting high sampling demand. Aim: In the absence of such equipment for identification, we introduce the flow injection analysis (FIA)-MRM3 technique and demonstrated its capabilities for quick identification of both isomeric compounds without liquid chromatography (LC) separation through the addition of selectivity criteria in the MRM3 mode. Method: 20 to 100 ng/mL of MA and PTM, respectively, in whole blood sample (WBS) and dried blood stain (DBS) were used to develop the method for the identification and relative quantification. Twenty whole blood samples which were reported positive of the drugs were randomly selected and were individually stained onto the Flinders Technology Associates (FTA) card for DBS study. Results: The peaks from the two isomeric compounds were successfully discerned for all the tested specimens using the FIA-MRM3 spectrometry technique. The limit of detection (LOD) and limit of quantification (LOQ) for MA and PTM were comparable to normal liquid chromatography-tandem mass spectrometry runs at 2.23 and 2.07 ng/mL, respectively, for WBS (n = 30). For DBS, the LOD and LOQ were 3.40 and 2.86 ng/mL, respectively. The accuracy and inter-day precision for DBS and WBS were in the range of 99.97–111.19% and 7.17–9.55%, respectively. Conclusion: These results demonstrated that the technique is highly adoptable in the screening of isomeric compounds of similar masses in a simple and rapid analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Predicted aerosol dosimetry for mouse models of chronic obstructive pulmonary disease, cardiovascular disease and lung cancer Banana peel extract alleviate inflammation and oxidative stress via modulation of the Nrf2/Hmox-1 and NF-κB pathways in thyroid of heavy metal mixture exposed female rats Safety evaluation of oubli fruit sweet protein (brazzein) derived from Komagataella phaffii, intended for use as a sweetener in food and beverages A randomized, open-label, cross-over pilot study investigating metabolic product kinetics of the palatable novel ketone ester, bis-octanoyl (R)-1,3-butanediol, and bis-hexanoyl (R)-1,3-butanediol ingestion in healthy adults Assessment of level of heavy metals in cosmetics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1