亥姆霍兹谐振器增强的液压能量采集器

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2015-04-02 DOI:10.1117/12.2084343
E. Skow, Zachary Koontz, K. Cunefare, A. Erturk
{"title":"亥姆霍兹谐振器增强的液压能量采集器","authors":"E. Skow, Zachary Koontz, K. Cunefare, A. Erturk","doi":"10.1117/12.2084343","DOIUrl":null,"url":null,"abstract":"Hydraulic pressure energy harvesters (HPEH) are devices that convert the dynamic pressure within hydraulic systems into usable electrical power through axially loaded piezoelectric stacks excited off-resonance by the fluid. Within hydraulic systems, the dominant frequency is typically a harmonic of the pump operating frequency. The pressure fluctuations coupled with the piezoelectric stack can be amplified by creating a housing design that includes a Helmholtz resonator tuned to the dominant frequency of the fluid excitation. A Helmholtz resonator is an acoustic device that consists of a cavity coupled to a fluid medium via a neck, or in this case a port connection to the fluid flow, that acts as an amplifier when within the bandwidth of its resonance. The implementation of a piezoelectric stack within the HPEH allows for a Helmholtz resonator to be included within the fluidic environment despite the significantly higher than air static pressures typical of fluid hydraulic systems (on the order of one to tens of MPa). The resistive losses within the system, such as from energy harvesting and viscous losses, can also be used to increase the bandwidth of the resonance; thus increasing the utility of the device. This paper investigates the design, modeling, and performance of hydraulic pressure energy harvesters utilizing a Helmholtz resonator design.","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2015-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Hydraulic pressure energy harvester enhanced by Helmholtz resonator\",\"authors\":\"E. Skow, Zachary Koontz, K. Cunefare, A. Erturk\",\"doi\":\"10.1117/12.2084343\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Hydraulic pressure energy harvesters (HPEH) are devices that convert the dynamic pressure within hydraulic systems into usable electrical power through axially loaded piezoelectric stacks excited off-resonance by the fluid. Within hydraulic systems, the dominant frequency is typically a harmonic of the pump operating frequency. The pressure fluctuations coupled with the piezoelectric stack can be amplified by creating a housing design that includes a Helmholtz resonator tuned to the dominant frequency of the fluid excitation. A Helmholtz resonator is an acoustic device that consists of a cavity coupled to a fluid medium via a neck, or in this case a port connection to the fluid flow, that acts as an amplifier when within the bandwidth of its resonance. The implementation of a piezoelectric stack within the HPEH allows for a Helmholtz resonator to be included within the fluidic environment despite the significantly higher than air static pressures typical of fluid hydraulic systems (on the order of one to tens of MPa). The resistive losses within the system, such as from energy harvesting and viscous losses, can also be used to increase the bandwidth of the resonance; thus increasing the utility of the device. This paper investigates the design, modeling, and performance of hydraulic pressure energy harvesters utilizing a Helmholtz resonator design.\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2015-04-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2084343\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1117/12.2084343","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 6

摘要

液压能量收集器(HPEH)是一种将液压系统内的动压力转化为可用电力的装置,它通过轴向加载的压电堆被流体激发出非共振。在液压系统中,主导频率通常是泵工作频率的谐波。通过创建一个包含可调谐到流体激励主频率的亥姆霍兹谐振器的外壳设计,可以放大与压电堆栈耦合的压力波动。亥姆霍兹谐振器是一种声学装置,它由一个腔通过颈部耦合到流体介质,或者在这种情况下是一个连接到流体流动的端口,在其谐振带宽内充当放大器。在HPEH内实现压电堆栈允许亥姆霍兹谐振器包含在流体环境中,尽管流体液压系统的典型空气静压明显高于空气静压(约为1至数十MPa)。系统内的电阻损失,如能量收集和粘性损失,也可以用来增加共振的带宽;从而增加了设备的效用。本文研究了利用亥姆霍兹谐振腔设计的液压能量采集器的设计、建模和性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Hydraulic pressure energy harvester enhanced by Helmholtz resonator
Hydraulic pressure energy harvesters (HPEH) are devices that convert the dynamic pressure within hydraulic systems into usable electrical power through axially loaded piezoelectric stacks excited off-resonance by the fluid. Within hydraulic systems, the dominant frequency is typically a harmonic of the pump operating frequency. The pressure fluctuations coupled with the piezoelectric stack can be amplified by creating a housing design that includes a Helmholtz resonator tuned to the dominant frequency of the fluid excitation. A Helmholtz resonator is an acoustic device that consists of a cavity coupled to a fluid medium via a neck, or in this case a port connection to the fluid flow, that acts as an amplifier when within the bandwidth of its resonance. The implementation of a piezoelectric stack within the HPEH allows for a Helmholtz resonator to be included within the fluidic environment despite the significantly higher than air static pressures typical of fluid hydraulic systems (on the order of one to tens of MPa). The resistive losses within the system, such as from energy harvesting and viscous losses, can also be used to increase the bandwidth of the resonance; thus increasing the utility of the device. This paper investigates the design, modeling, and performance of hydraulic pressure energy harvesters utilizing a Helmholtz resonator design.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1