{"title":"三维光动力治疗照明系统的标定及其对波特酒斑的分割评价","authors":"Yun-qiu Feng, Xiaoming Hu, Ya Zhou, Yong Wang","doi":"10.1515/plm-2016-0014","DOIUrl":null,"url":null,"abstract":"Abstract The uniformity of light dosimetry is an important parameter that affects the efficacy of photodynamic therapy (PDT). Although this uniformity can be improved by a three-dimensional (3D) digital PDT illumination system, it has a low field-of-view (FOV) utilization rate. A checkerboard calibration method using color coding is proposed to calibrate both the projector and camera of the system with a broad common FOV. Experiments reveal that the proposed method increases the utilization rate by up to three times compared with noncolor-coding methods with almost the same accuracy. A fine distinction of phantom lesions in the 3D system can be obtained by clustering, which may be used to optimize the treatment and light-dosimetry evaluation.","PeriodicalId":20126,"journal":{"name":"Photonics & Lasers in Medicine","volume":"5 1","pages":"195 - 202"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Calibration of a three-dimensional photodynamic therapy illumination system and its segmentation assessment for port-wine stains\",\"authors\":\"Yun-qiu Feng, Xiaoming Hu, Ya Zhou, Yong Wang\",\"doi\":\"10.1515/plm-2016-0014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The uniformity of light dosimetry is an important parameter that affects the efficacy of photodynamic therapy (PDT). Although this uniformity can be improved by a three-dimensional (3D) digital PDT illumination system, it has a low field-of-view (FOV) utilization rate. A checkerboard calibration method using color coding is proposed to calibrate both the projector and camera of the system with a broad common FOV. Experiments reveal that the proposed method increases the utilization rate by up to three times compared with noncolor-coding methods with almost the same accuracy. A fine distinction of phantom lesions in the 3D system can be obtained by clustering, which may be used to optimize the treatment and light-dosimetry evaluation.\",\"PeriodicalId\":20126,\"journal\":{\"name\":\"Photonics & Lasers in Medicine\",\"volume\":\"5 1\",\"pages\":\"195 - 202\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Photonics & Lasers in Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/plm-2016-0014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photonics & Lasers in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/plm-2016-0014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Calibration of a three-dimensional photodynamic therapy illumination system and its segmentation assessment for port-wine stains
Abstract The uniformity of light dosimetry is an important parameter that affects the efficacy of photodynamic therapy (PDT). Although this uniformity can be improved by a three-dimensional (3D) digital PDT illumination system, it has a low field-of-view (FOV) utilization rate. A checkerboard calibration method using color coding is proposed to calibrate both the projector and camera of the system with a broad common FOV. Experiments reveal that the proposed method increases the utilization rate by up to three times compared with noncolor-coding methods with almost the same accuracy. A fine distinction of phantom lesions in the 3D system can be obtained by clustering, which may be used to optimize the treatment and light-dosimetry evaluation.