降低三相逆变器共模电压

Sibi Raj P M, M. Rashmi
{"title":"降低三相逆变器共模电压","authors":"Sibi Raj P M, M. Rashmi","doi":"10.1109/TAPENERGY.2015.7229625","DOIUrl":null,"url":null,"abstract":"Pulse Width Modulated (PWM) inverters produce common mode voltage. The common mode voltage will have adverse effect on the motor bearings. Hence the common mode voltage has to be reduced. This paper presents a modified Sinusoidal Pulse Width Modulation (SPWM) scheme in which two complementary modulating inputs are used to generate the pulses for the switches of a two level, three phase inverter to reduce the common mode voltage. The performance of proposed modulation scheme is evaluated and tested for various switching frequencies. With the proposed modulation scheme the phase voltages appears to be three level voltage which helps in reduction of common mode voltage. A comparative study of common mode voltage with both normal and modified SPWM method is also done and the results are presented in this paper.","PeriodicalId":6552,"journal":{"name":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","volume":"5 1","pages":"244-248"},"PeriodicalIF":0.0000,"publicationDate":"2015-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Reduction of common mode voltage in three phase inverter\",\"authors\":\"Sibi Raj P M, M. Rashmi\",\"doi\":\"10.1109/TAPENERGY.2015.7229625\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Pulse Width Modulated (PWM) inverters produce common mode voltage. The common mode voltage will have adverse effect on the motor bearings. Hence the common mode voltage has to be reduced. This paper presents a modified Sinusoidal Pulse Width Modulation (SPWM) scheme in which two complementary modulating inputs are used to generate the pulses for the switches of a two level, three phase inverter to reduce the common mode voltage. The performance of proposed modulation scheme is evaluated and tested for various switching frequencies. With the proposed modulation scheme the phase voltages appears to be three level voltage which helps in reduction of common mode voltage. A comparative study of common mode voltage with both normal and modified SPWM method is also done and the results are presented in this paper.\",\"PeriodicalId\":6552,\"journal\":{\"name\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"volume\":\"5 1\",\"pages\":\"244-248\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TAPENERGY.2015.7229625\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TAPENERGY.2015.7229625","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

脉宽调制(PWM)逆变器产生共模电压。共模电压会对电机轴承产生不利影响。因此,共模电压必须降低。本文提出了一种改进的正弦脉宽调制(SPWM)方案,该方案采用两个互补调制输入为二电平三相逆变器的开关产生脉冲,以降低共模电压。对所提出的调制方案在不同开关频率下的性能进行了评估和测试。采用所提出的调制方案,相位电压呈现为三电平电压,有助于降低共模电压。本文还对普通和改进SPWM方法的共模电压进行了比较研究,并给出了结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reduction of common mode voltage in three phase inverter
Pulse Width Modulated (PWM) inverters produce common mode voltage. The common mode voltage will have adverse effect on the motor bearings. Hence the common mode voltage has to be reduced. This paper presents a modified Sinusoidal Pulse Width Modulation (SPWM) scheme in which two complementary modulating inputs are used to generate the pulses for the switches of a two level, three phase inverter to reduce the common mode voltage. The performance of proposed modulation scheme is evaluated and tested for various switching frequencies. With the proposed modulation scheme the phase voltages appears to be three level voltage which helps in reduction of common mode voltage. A comparative study of common mode voltage with both normal and modified SPWM method is also done and the results are presented in this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reduction of common mode voltage in three phase inverter A novel topology of forward-flyback PFC converter with constant on-time control Online benefit optimization in a liberalized/free microgrid market model UHVDC transmission with dedicated metallic return Bridgeless flyback converter for low power lighting application
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1