在机器人辅助微创手术中测量器官移位和变形

Mohammad R. Maddah , Cedric Dumas , Olivier Gauthier , Marion Fusellier , Caroline G.L. Cao
{"title":"在机器人辅助微创手术中测量器官移位和变形","authors":"Mohammad R. Maddah ,&nbsp;Cedric Dumas ,&nbsp;Olivier Gauthier ,&nbsp;Marion Fusellier ,&nbsp;Caroline G.L. Cao","doi":"10.1016/j.lers.2020.09.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>Port placement is a crucial pre-operative task in robot-assisted minimally invasive surgery. Due to the insufflation process, the abdominal shape is deformed while the internal organs are shifted in position. These changes need to be considered when determining the optimal port locations for the robotic manipulators. However, intra-operative medical image acquisition systems are not always available. In this study, we aim to estimate the shift extent of the abdominal organs in humans by measuring the changed volume and position of the abdominal organs before and after insufflation in three pigs.</p></div><div><h3>Methods</h3><p>A 3D model of the abdomen and abdominal organs was reconstructed from 3D images of the pigs taken by an MRI scanner before and after insufflation. Position shift and shape changes of the abdominal organs after insufflation were determined. The corresponding shift in port location for the robotic manipulators was determined based on the abdominal model.</p></div><div><h3>Results</h3><p>Organ movements as a result of insufflation ranged from 6.37 ± 0.10 cm for the spleen, to 1.64 ± 0.22 cm for the liver. Even a slight planar motion of the target organ (e.g., 1.33 ± 0.06 cm, 2.38 ± 0.21 cm in X-Y plane for the left kidney) can shift the access port for the robot manipulator by about 1.6 cm on the abdominal surface.</p></div><div><h3>Conclusions</h3><p>The target organs’ motion due to insufflation is a critical factor in determining port locations in robot-assisted minimally invasive surgery.</p></div>","PeriodicalId":32893,"journal":{"name":"Laparoscopic Endoscopic and Robotic Surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.lers.2020.09.002","citationCount":"2","resultStr":"{\"title\":\"Measuring organ shift and deformation for port placement in robot-assisted minimally invasive surgery\",\"authors\":\"Mohammad R. Maddah ,&nbsp;Cedric Dumas ,&nbsp;Olivier Gauthier ,&nbsp;Marion Fusellier ,&nbsp;Caroline G.L. Cao\",\"doi\":\"10.1016/j.lers.2020.09.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>Port placement is a crucial pre-operative task in robot-assisted minimally invasive surgery. Due to the insufflation process, the abdominal shape is deformed while the internal organs are shifted in position. These changes need to be considered when determining the optimal port locations for the robotic manipulators. However, intra-operative medical image acquisition systems are not always available. In this study, we aim to estimate the shift extent of the abdominal organs in humans by measuring the changed volume and position of the abdominal organs before and after insufflation in three pigs.</p></div><div><h3>Methods</h3><p>A 3D model of the abdomen and abdominal organs was reconstructed from 3D images of the pigs taken by an MRI scanner before and after insufflation. Position shift and shape changes of the abdominal organs after insufflation were determined. The corresponding shift in port location for the robotic manipulators was determined based on the abdominal model.</p></div><div><h3>Results</h3><p>Organ movements as a result of insufflation ranged from 6.37 ± 0.10 cm for the spleen, to 1.64 ± 0.22 cm for the liver. Even a slight planar motion of the target organ (e.g., 1.33 ± 0.06 cm, 2.38 ± 0.21 cm in X-Y plane for the left kidney) can shift the access port for the robot manipulator by about 1.6 cm on the abdominal surface.</p></div><div><h3>Conclusions</h3><p>The target organs’ motion due to insufflation is a critical factor in determining port locations in robot-assisted minimally invasive surgery.</p></div>\",\"PeriodicalId\":32893,\"journal\":{\"name\":\"Laparoscopic Endoscopic and Robotic Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.lers.2020.09.002\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laparoscopic Endoscopic and Robotic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S246890092030058X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laparoscopic Endoscopic and Robotic Surgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S246890092030058X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

摘要

目的:在机器人辅助微创手术中,气道放置是一项重要的术前任务。由于充气过程,腹部形状发生变形,内脏器官位置发生移位。在确定机械臂的最佳端口位置时,需要考虑这些变化。然而,术中医学图像采集系统并不总是可用的。在这项研究中,我们的目的是通过测量3只猪在充气前后腹部器官的体积和位置的变化来估计人类腹部器官的移位程度。方法利用磁共振成像(MRI)对猪进行充气前后的三维成像,重建猪腹部和腹部器官的三维模型。观察充气后腹部脏器的位置移位和形态变化。基于腹部模型,确定了机械臂端口位置的相应移位。结果脾脏(6.37±0.10 cm)和肝脏(1.64±0.22 cm)因充气引起的脏器运动。即使目标器官的轻微平面运动(如左肾在X-Y平面上1.33±0.06 cm, 2.38±0.21 cm)也可以使机器人机械手的入口在腹部表面移动约1.6 cm。结论在机器人辅助微创手术中,靶器官因充气引起的运动是确定手术端口位置的关键因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measuring organ shift and deformation for port placement in robot-assisted minimally invasive surgery

Objective

Port placement is a crucial pre-operative task in robot-assisted minimally invasive surgery. Due to the insufflation process, the abdominal shape is deformed while the internal organs are shifted in position. These changes need to be considered when determining the optimal port locations for the robotic manipulators. However, intra-operative medical image acquisition systems are not always available. In this study, we aim to estimate the shift extent of the abdominal organs in humans by measuring the changed volume and position of the abdominal organs before and after insufflation in three pigs.

Methods

A 3D model of the abdomen and abdominal organs was reconstructed from 3D images of the pigs taken by an MRI scanner before and after insufflation. Position shift and shape changes of the abdominal organs after insufflation were determined. The corresponding shift in port location for the robotic manipulators was determined based on the abdominal model.

Results

Organ movements as a result of insufflation ranged from 6.37 ± 0.10 cm for the spleen, to 1.64 ± 0.22 cm for the liver. Even a slight planar motion of the target organ (e.g., 1.33 ± 0.06 cm, 2.38 ± 0.21 cm in X-Y plane for the left kidney) can shift the access port for the robot manipulator by about 1.6 cm on the abdominal surface.

Conclusions

The target organs’ motion due to insufflation is a critical factor in determining port locations in robot-assisted minimally invasive surgery.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Laparoscopic Endoscopic and Robotic Surgery
Laparoscopic Endoscopic and Robotic Surgery minimally invasive surgery-
CiteScore
1.40
自引率
0.00%
发文量
32
期刊介绍: Laparoscopic, Endoscopic and Robotic Surgery aims to provide an academic exchange platform for minimally invasive surgery at an international level. We seek out and publish the excellent original articles, reviews and editorials as well as exciting new techniques to promote the academic development. Topics of interests include, but are not limited to: ▪ Minimally invasive clinical research mainly in General Surgery, Thoracic Surgery, Urology, Neurosurgery, Gynecology & Obstetrics, Gastroenterology, Orthopedics, Colorectal Surgery, Otolaryngology, etc.; ▪ Basic research in minimally invasive surgery; ▪ Research of techniques and equipments in minimally invasive surgery, and application of laparoscopy, endoscopy, robot and medical imaging; ▪ Development of medical education in minimally invasive surgery.
期刊最新文献
Gastric leiomyoma presenting as an endophytic growth of cardia of the stomach: A case report A live birth resulting from a fourth cesarean scar pregnancy after combined hysteroscopic and laparoscopic uterine repair: A case report and literature review A new abdominal drainage tube fixation method for 3-port laparoscopic cholecystectomy improves patients’ postoperative quality of life Managerial perspectives of scaling up robotic-assisted surgery in healthcare systems: A systematic literature review Minimally invasive management of parapharyngeal space tumors: Introducing a decision-making algorithm and radiologic tool
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1