Mircea Popescu, D. Dorrell, L. Alberti, N. Bianchi, D. Staton, D. Hawkins
{"title":"双相三相异步电动机故障工况下的热分析","authors":"Mircea Popescu, D. Dorrell, L. Alberti, N. Bianchi, D. Staton, D. Hawkins","doi":"10.1109/ICELMACH.2012.6350137","DOIUrl":null,"url":null,"abstract":"The paper describes a thermal model for a duplex three-phase induction machine for fault tolerant applications. Three-phase and six-phase variations of duplex three-phase machine operation under fault conditions are considered. Different winding configurations are investigated. Thermal analysis is performed using analytical and finite-element models. Experimental validation is presented for load operating conditions.","PeriodicalId":6309,"journal":{"name":"2012 XXth International Conference on Electrical Machines","volume":"5 1","pages":"1875-1881"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"42","resultStr":"{\"title\":\"Thermal analysis of duplex 3-phase induction motor under fault operating conditions\",\"authors\":\"Mircea Popescu, D. Dorrell, L. Alberti, N. Bianchi, D. Staton, D. Hawkins\",\"doi\":\"10.1109/ICELMACH.2012.6350137\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper describes a thermal model for a duplex three-phase induction machine for fault tolerant applications. Three-phase and six-phase variations of duplex three-phase machine operation under fault conditions are considered. Different winding configurations are investigated. Thermal analysis is performed using analytical and finite-element models. Experimental validation is presented for load operating conditions.\",\"PeriodicalId\":6309,\"journal\":{\"name\":\"2012 XXth International Conference on Electrical Machines\",\"volume\":\"5 1\",\"pages\":\"1875-1881\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"42\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 XXth International Conference on Electrical Machines\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICELMACH.2012.6350137\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 XXth International Conference on Electrical Machines","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2012.6350137","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Thermal analysis of duplex 3-phase induction motor under fault operating conditions
The paper describes a thermal model for a duplex three-phase induction machine for fault tolerant applications. Three-phase and six-phase variations of duplex three-phase machine operation under fault conditions are considered. Different winding configurations are investigated. Thermal analysis is performed using analytical and finite-element models. Experimental validation is presented for load operating conditions.