GTAW- al6061焊接结果的拉伸强度和显微组织分析

Ardani Ahsanul Fakhri, Basyirun Basyirun, Ahmad Fikrie
{"title":"GTAW- al6061焊接结果的拉伸强度和显微组织分析","authors":"Ardani Ahsanul Fakhri, Basyirun Basyirun, Ahmad Fikrie","doi":"10.21831/jeatech.v3i2.53149","DOIUrl":null,"url":null,"abstract":"The process of joining aluminum metal requires a special welding method. The use of GTAW welding is a suitable method for joining aluminum plates. This research is intended to analyze the tensile strength and microstructure of the GTAW Aluminum 6061 welding with various currents. The research method used in this research is experimental research. Welding current variations used in this study were 100A, 115A, and 130A, then tested using a destructive test, tensile test. The data analysis used in this study is descriptive analysis, where the data obtained are averaged and then described and concluded. The results of microstructure research on GTAW welding show that changes in the microstructure are very visible in the HAZ area and the weld metal, the greater the heat input, the more spread the Mg2Si grains will be. Good structural dispersion only occurs at 130A current. This is different from the base metal which does not change the material structure at all. Based on the tensile test, the tensile stress value is 80.9 MPa at 100 A current, 84.9 MPa at 115A current variation, and the highest tensile strength is 86.7 MPa at 130A current. So, it can be concluded that the higher the current used, the better the microstructure and tensile strength produced.","PeriodicalId":8524,"journal":{"name":"Asian Journal of Engineering and Applied Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of tensile strength and microstructure on GTAW- Aluminum 6061 welding results\",\"authors\":\"Ardani Ahsanul Fakhri, Basyirun Basyirun, Ahmad Fikrie\",\"doi\":\"10.21831/jeatech.v3i2.53149\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The process of joining aluminum metal requires a special welding method. The use of GTAW welding is a suitable method for joining aluminum plates. This research is intended to analyze the tensile strength and microstructure of the GTAW Aluminum 6061 welding with various currents. The research method used in this research is experimental research. Welding current variations used in this study were 100A, 115A, and 130A, then tested using a destructive test, tensile test. The data analysis used in this study is descriptive analysis, where the data obtained are averaged and then described and concluded. The results of microstructure research on GTAW welding show that changes in the microstructure are very visible in the HAZ area and the weld metal, the greater the heat input, the more spread the Mg2Si grains will be. Good structural dispersion only occurs at 130A current. This is different from the base metal which does not change the material structure at all. Based on the tensile test, the tensile stress value is 80.9 MPa at 100 A current, 84.9 MPa at 115A current variation, and the highest tensile strength is 86.7 MPa at 130A current. So, it can be concluded that the higher the current used, the better the microstructure and tensile strength produced.\",\"PeriodicalId\":8524,\"journal\":{\"name\":\"Asian Journal of Engineering and Applied Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Engineering and Applied Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21831/jeatech.v3i2.53149\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Engineering and Applied Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21831/jeatech.v3i2.53149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

连接铝金属的过程需要一种特殊的焊接方法。采用GTAW焊接是一种比较合适的铝板连接方法。本研究旨在分析GTAW铝合金6061焊接在不同电流下的拉伸强度和显微组织。本研究采用的研究方法是实验研究。本研究中使用的焊接电流变化为100A、115A和130A,然后使用破坏性试验、拉伸试验进行测试。本研究使用的数据分析是描述性分析,即对获得的数据进行平均,然后进行描述和总结。GTAW焊接的显微组织研究结果表明,热影响区和焊缝金属的显微组织变化非常明显,热输入越大,Mg2Si晶粒分布越广。良好的结构色散只发生在130A电流下。这与根本不改变材料结构的母材不同。通过拉伸试验可知,在100 A电流下拉伸应力值为80.9 MPa,在115A电流变化时拉伸应力值为84.9 MPa,在130A电流下拉伸强度最高为86.7 MPa。由此可知,电流越大,合金的显微组织越好,抗拉强度越高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of tensile strength and microstructure on GTAW- Aluminum 6061 welding results
The process of joining aluminum metal requires a special welding method. The use of GTAW welding is a suitable method for joining aluminum plates. This research is intended to analyze the tensile strength and microstructure of the GTAW Aluminum 6061 welding with various currents. The research method used in this research is experimental research. Welding current variations used in this study were 100A, 115A, and 130A, then tested using a destructive test, tensile test. The data analysis used in this study is descriptive analysis, where the data obtained are averaged and then described and concluded. The results of microstructure research on GTAW welding show that changes in the microstructure are very visible in the HAZ area and the weld metal, the greater the heat input, the more spread the Mg2Si grains will be. Good structural dispersion only occurs at 130A current. This is different from the base metal which does not change the material structure at all. Based on the tensile test, the tensile stress value is 80.9 MPa at 100 A current, 84.9 MPa at 115A current variation, and the highest tensile strength is 86.7 MPa at 130A current. So, it can be concluded that the higher the current used, the better the microstructure and tensile strength produced.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fatigue Analysis of Engine Blade Structure Considering Thermal Loads Feature Extraction Based Machine Learning Approach for Bone Cancer Detection Design of brake failure control on motorcycle disc brakes through an integrated cooling system Evaluation of capacity and number of gates for delays and fuel consumption in the FTSP UII parking area Energy balance of thermal and catalytic degradation processes of plastic waste for producing alternative fuel
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1