{"title":"盐酸洛哌丁胺片剂吸光度法和曲线下面积法分析方法的建立与验证","authors":"H. Rivai, Renny Puspita, Sesry Misfadhila","doi":"10.9734/bpi/tipr/v3/1696c","DOIUrl":null,"url":null,"abstract":"Development and validation of loperamide hydrochloride tablet method of analysis have been done by using the absorbance method and area under the curve method. This study used methanol and hydrochloric acid 0.1 N (9:1) as the best solvent with maximum absorption at wavelength 259.00 nm. The linearity of loperamide hydrochloride was obtained in the concentration range 200-600 ppm with a correlation coefficient value with the absorbance method and the areas under the curve method were 0.9998 and 0.9865, respectively. The results showed that the levels of loperamide hydrochloride in generic tablets obtained by absorbance method and the area under the curve method were 105.71% and 96.20%, respectively. The results of determination of loperamide levels in tablets of trademark obtained by absorbance method and the area under the curve method were 102.85% and 98.57%, respectively. The level of both samples met the requirements of Pharmacopoeia Indonesia edition V that is 90% -110%. The analysis of loperamide hydrochloride in tablets by ultraviolet-visible spectrophotometry by absorbance method is valid while the area under the curve method is invalid for analysis of loperamide hydrochloride in tablets.","PeriodicalId":22329,"journal":{"name":"Technological Innovation in Pharmaceutical Research Vol. 3","volume":"22 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Recent Study on Development and Validation of Loperamide Hydrochloride Tablet Analysis Method with Absorbance and Area under Curve Methods Spectrophotometrically\",\"authors\":\"H. Rivai, Renny Puspita, Sesry Misfadhila\",\"doi\":\"10.9734/bpi/tipr/v3/1696c\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Development and validation of loperamide hydrochloride tablet method of analysis have been done by using the absorbance method and area under the curve method. This study used methanol and hydrochloric acid 0.1 N (9:1) as the best solvent with maximum absorption at wavelength 259.00 nm. The linearity of loperamide hydrochloride was obtained in the concentration range 200-600 ppm with a correlation coefficient value with the absorbance method and the areas under the curve method were 0.9998 and 0.9865, respectively. The results showed that the levels of loperamide hydrochloride in generic tablets obtained by absorbance method and the area under the curve method were 105.71% and 96.20%, respectively. The results of determination of loperamide levels in tablets of trademark obtained by absorbance method and the area under the curve method were 102.85% and 98.57%, respectively. The level of both samples met the requirements of Pharmacopoeia Indonesia edition V that is 90% -110%. The analysis of loperamide hydrochloride in tablets by ultraviolet-visible spectrophotometry by absorbance method is valid while the area under the curve method is invalid for analysis of loperamide hydrochloride in tablets.\",\"PeriodicalId\":22329,\"journal\":{\"name\":\"Technological Innovation in Pharmaceutical Research Vol. 3\",\"volume\":\"22 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technological Innovation in Pharmaceutical Research Vol. 3\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9734/bpi/tipr/v3/1696c\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technological Innovation in Pharmaceutical Research Vol. 3","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/bpi/tipr/v3/1696c","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Recent Study on Development and Validation of Loperamide Hydrochloride Tablet Analysis Method with Absorbance and Area under Curve Methods Spectrophotometrically
Development and validation of loperamide hydrochloride tablet method of analysis have been done by using the absorbance method and area under the curve method. This study used methanol and hydrochloric acid 0.1 N (9:1) as the best solvent with maximum absorption at wavelength 259.00 nm. The linearity of loperamide hydrochloride was obtained in the concentration range 200-600 ppm with a correlation coefficient value with the absorbance method and the areas under the curve method were 0.9998 and 0.9865, respectively. The results showed that the levels of loperamide hydrochloride in generic tablets obtained by absorbance method and the area under the curve method were 105.71% and 96.20%, respectively. The results of determination of loperamide levels in tablets of trademark obtained by absorbance method and the area under the curve method were 102.85% and 98.57%, respectively. The level of both samples met the requirements of Pharmacopoeia Indonesia edition V that is 90% -110%. The analysis of loperamide hydrochloride in tablets by ultraviolet-visible spectrophotometry by absorbance method is valid while the area under the curve method is invalid for analysis of loperamide hydrochloride in tablets.