{"title":"CMS-ME0探测器新型三重gem机械设计、初步性能及研发成果","authors":"D. Fiorina","doi":"10.1109/NSS/MIC42677.2020.9507748","DOIUrl":null,"url":null,"abstract":"In the framework of the HL-LHC project, the upgrade of the CMS Muon System foresees the installation of three new muon stations based on the GEM technology, named as GE1/1, GE2/1 and ME0. The CMS GEM Group has developed a novel construction design of GE1/1 triple-GEM detectors; especially, a new self-stretching technique has been introduced to mechanically stretch the GEM foils without using spacer grids or glue inside the gas volume. As has been observed, the PCB boards get deformed under the internal gas overpressure, introducing irregularities in the planarity of the detector, which could potentially affect the uniformity of the detector performance. New solutions and design upgrades have been implemented to prevent such effects in future GE2/1 and ME0 upgrade projects. The contribution will focus on the novel design solutions based on the PCB pillars and their impact on the performance of the detector. Furthermore, the early results of the R&D campaign will be presented regarding the optimization of the detector for the very high hit rate environment and the reduction of the discharge probability.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"31 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Novel Triple-GEM Mechanical Design for the CMS-ME0 Detector, Preliminary Performance and R&D Results\",\"authors\":\"D. Fiorina\",\"doi\":\"10.1109/NSS/MIC42677.2020.9507748\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the framework of the HL-LHC project, the upgrade of the CMS Muon System foresees the installation of three new muon stations based on the GEM technology, named as GE1/1, GE2/1 and ME0. The CMS GEM Group has developed a novel construction design of GE1/1 triple-GEM detectors; especially, a new self-stretching technique has been introduced to mechanically stretch the GEM foils without using spacer grids or glue inside the gas volume. As has been observed, the PCB boards get deformed under the internal gas overpressure, introducing irregularities in the planarity of the detector, which could potentially affect the uniformity of the detector performance. New solutions and design upgrades have been implemented to prevent such effects in future GE2/1 and ME0 upgrade projects. The contribution will focus on the novel design solutions based on the PCB pillars and their impact on the performance of the detector. Furthermore, the early results of the R&D campaign will be presented regarding the optimization of the detector for the very high hit rate environment and the reduction of the discharge probability.\",\"PeriodicalId\":6760,\"journal\":{\"name\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"volume\":\"31 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSS/MIC42677.2020.9507748\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSS/MIC42677.2020.9507748","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在HL-LHC项目的框架内,CMS μ子系统的升级预计将安装三个基于GEM技术的新μ子站,分别命名为GE1/1、GE2/1和ME0。CMS GEM组开发了GE1/1三重GEM探测器的新型结构设计;特别是,一种新的自拉伸技术已经被引入到机械拉伸GEM箔,而不使用间隔网格或胶在气体体积内。正如我们所观察到的,PCB板在内部气体超压下会发生变形,导致探测器的平面度不规则,这可能会影响探测器性能的均匀性。在未来的GE2/1和ME0升级项目中,已经实施了新的解决方案和设计升级,以防止此类影响。贡献将集中在基于PCB柱的新颖设计解决方案及其对探测器性能的影响。此外,研发活动的早期结果将展示关于探测器在非常高命中率环境下的优化和降低放电概率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Novel Triple-GEM Mechanical Design for the CMS-ME0 Detector, Preliminary Performance and R&D Results
In the framework of the HL-LHC project, the upgrade of the CMS Muon System foresees the installation of three new muon stations based on the GEM technology, named as GE1/1, GE2/1 and ME0. The CMS GEM Group has developed a novel construction design of GE1/1 triple-GEM detectors; especially, a new self-stretching technique has been introduced to mechanically stretch the GEM foils without using spacer grids or glue inside the gas volume. As has been observed, the PCB boards get deformed under the internal gas overpressure, introducing irregularities in the planarity of the detector, which could potentially affect the uniformity of the detector performance. New solutions and design upgrades have been implemented to prevent such effects in future GE2/1 and ME0 upgrade projects. The contribution will focus on the novel design solutions based on the PCB pillars and their impact on the performance of the detector. Furthermore, the early results of the R&D campaign will be presented regarding the optimization of the detector for the very high hit rate environment and the reduction of the discharge probability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance of Dual-Ended Readout PET Detectors Based on SiPMs with Different Microcell Sizes Neural Network-based Inter-crystal Scatter Event Positioning in a PET System Design Based on 3D Position Sensitive Detectors An e-LINAC driven PGNAA system for concealed drug inspection Design of a Multi-Technology Pre-Clinical SPECT System Comprehensive Simulation and Design of 3D Silicon Sensors for Enhanced Timing Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1