含10-MDP的全蚀刻和自蚀刻通用胶粘剂的微拉伸粘结强度:系统综述

I. H. Ismail, N. Razak, N. Ramzi, M.Y.P. Mohd Yusof
{"title":"含10-MDP的全蚀刻和自蚀刻通用胶粘剂的微拉伸粘结强度:系统综述","authors":"I. H. Ismail, N. Razak, N. Ramzi, M.Y.P. Mohd Yusof","doi":"10.12974/2311-8695.2022.10.03","DOIUrl":null,"url":null,"abstract":"A systematic review was performed to compare the human dentin microtensile bond strength of universal adhesives with 10-MDP when used as total-etch and self-etch strategies. Literature search was done on October 2019 without limitations on the language of publication, in four databases: PubMed, Web of Science, Scopus, and EBSCO. Additional manual search was done for the grey literature articles: OpenGrey and OpenThesis. Studies that evaluated the dentin bond strength of universal adhesives with 10-MDP using total-etch and self-etch strategy from the year 2000 up till October 2019 were included. The initial search resulted in 5121 references: 2234 from PubMed, 1814 from Scopus, 516 from Web of Science, 553 from EBSCO and 4 from OpenThesis. After full text analysis, 30 references were included in this systematic review. Seven different universal adhesives with 10-MDP were evaluated for dentin microtensile bond strength comparing total-etch and self-etch strategies: Single Bond Universal/Scotchbond Universal (3M ESPE), All Bond Universal (Bisco), Clearfil Universal Bond (Kuraray), G-Premio Bond (GC Corp), Tetric Bond Universal (Ivoclar Vivadent), Ambar Universal (FGM) and One Coat 7 Universal (Coltene). The total-etch strategy improved the dentine microtensile bond strength compared to self-etch strategy for all universal adhesives when stored in all three conditions: 24h, thermocycling and long-term immersion according to ISO (TS 11405:2015(E)). The evidence suggests that microtensile bond strength of universal adhesives containing 10-MDP may be improved utilizing total-etch strategy compared to self-etch strategy. This study provides valuable information on the importance of appropriate dentin adhesives strategy that affect success rate of restorations, which helps clinicians to make informed decisions on the strategy to be used during restorations in practice.","PeriodicalId":76664,"journal":{"name":"The Journal of the American College of Dentists","volume":"77 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Microtensile Bond Strength of Total-Etch and Self-Etch Universal Adhesives Containing 10-MDP: A Systematic Review\",\"authors\":\"I. H. Ismail, N. Razak, N. Ramzi, M.Y.P. Mohd Yusof\",\"doi\":\"10.12974/2311-8695.2022.10.03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A systematic review was performed to compare the human dentin microtensile bond strength of universal adhesives with 10-MDP when used as total-etch and self-etch strategies. Literature search was done on October 2019 without limitations on the language of publication, in four databases: PubMed, Web of Science, Scopus, and EBSCO. Additional manual search was done for the grey literature articles: OpenGrey and OpenThesis. Studies that evaluated the dentin bond strength of universal adhesives with 10-MDP using total-etch and self-etch strategy from the year 2000 up till October 2019 were included. The initial search resulted in 5121 references: 2234 from PubMed, 1814 from Scopus, 516 from Web of Science, 553 from EBSCO and 4 from OpenThesis. After full text analysis, 30 references were included in this systematic review. Seven different universal adhesives with 10-MDP were evaluated for dentin microtensile bond strength comparing total-etch and self-etch strategies: Single Bond Universal/Scotchbond Universal (3M ESPE), All Bond Universal (Bisco), Clearfil Universal Bond (Kuraray), G-Premio Bond (GC Corp), Tetric Bond Universal (Ivoclar Vivadent), Ambar Universal (FGM) and One Coat 7 Universal (Coltene). The total-etch strategy improved the dentine microtensile bond strength compared to self-etch strategy for all universal adhesives when stored in all three conditions: 24h, thermocycling and long-term immersion according to ISO (TS 11405:2015(E)). The evidence suggests that microtensile bond strength of universal adhesives containing 10-MDP may be improved utilizing total-etch strategy compared to self-etch strategy. This study provides valuable information on the importance of appropriate dentin adhesives strategy that affect success rate of restorations, which helps clinicians to make informed decisions on the strategy to be used during restorations in practice.\",\"PeriodicalId\":76664,\"journal\":{\"name\":\"The Journal of the American College of Dentists\",\"volume\":\"77 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of the American College of Dentists\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12974/2311-8695.2022.10.03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of the American College of Dentists","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12974/2311-8695.2022.10.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文比较了10-MDP和通用胶粘剂在全蚀刻和自蚀刻两种策略下的牙本质微拉伸结合强度。文献检索于2019年10月在PubMed、Web of Science、Scopus和EBSCO四个数据库中完成,不受出版语言的限制。对灰色文献文章进行了额外的人工搜索:OpenGrey和OpenThesis。从2000年到2019年10月,采用全蚀刻和自蚀刻策略评估了10-MDP通用胶粘剂的牙本质结合强度。最初的搜索结果是5121篇参考文献:2234篇来自PubMed, 1814篇来自Scopus, 516篇来自Web of Science, 553篇来自EBSCO, 4篇来自OpenThesis。经全文分析,本系统综述共收录文献30篇。7种不同的10-MDP万能粘合剂对牙本质微拉伸粘结强度进行了评估,并比较了全蚀和自蚀策略:Single bond universal /Scotchbond universal (3M ESPE)、All bond universal (Bisco)、Clearfil universal bond (Kuraray)、G-Premio bond (GC Corp)、Tetric bond universal (ivocar Vivadent)、Ambar universal (FGM)和One Coat 7 universal (Coltene)。根据ISO (TS 11405:2015(E)),在24小时、热循环和长期浸泡三种条件下,与自蚀策略相比,全蚀刻策略提高了所有通用粘合剂的牙本质微拉伸结合强度。结果表明,采用全蚀刻方法可以提高10-MDP通用胶粘剂的微拉伸强度。本研究为牙本质粘接剂策略对修复成功率的影响提供了有价值的信息,有助于临床医生在实际修复过程中做出明智的决策。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Microtensile Bond Strength of Total-Etch and Self-Etch Universal Adhesives Containing 10-MDP: A Systematic Review
A systematic review was performed to compare the human dentin microtensile bond strength of universal adhesives with 10-MDP when used as total-etch and self-etch strategies. Literature search was done on October 2019 without limitations on the language of publication, in four databases: PubMed, Web of Science, Scopus, and EBSCO. Additional manual search was done for the grey literature articles: OpenGrey and OpenThesis. Studies that evaluated the dentin bond strength of universal adhesives with 10-MDP using total-etch and self-etch strategy from the year 2000 up till October 2019 were included. The initial search resulted in 5121 references: 2234 from PubMed, 1814 from Scopus, 516 from Web of Science, 553 from EBSCO and 4 from OpenThesis. After full text analysis, 30 references were included in this systematic review. Seven different universal adhesives with 10-MDP were evaluated for dentin microtensile bond strength comparing total-etch and self-etch strategies: Single Bond Universal/Scotchbond Universal (3M ESPE), All Bond Universal (Bisco), Clearfil Universal Bond (Kuraray), G-Premio Bond (GC Corp), Tetric Bond Universal (Ivoclar Vivadent), Ambar Universal (FGM) and One Coat 7 Universal (Coltene). The total-etch strategy improved the dentine microtensile bond strength compared to self-etch strategy for all universal adhesives when stored in all three conditions: 24h, thermocycling and long-term immersion according to ISO (TS 11405:2015(E)). The evidence suggests that microtensile bond strength of universal adhesives containing 10-MDP may be improved utilizing total-etch strategy compared to self-etch strategy. This study provides valuable information on the importance of appropriate dentin adhesives strategy that affect success rate of restorations, which helps clinicians to make informed decisions on the strategy to be used during restorations in practice.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Usage of Antimicrobials in Pediatric Dentistry- A Narrative Review Present Status of the Effectiveness of the Patch Test Reagent for Titanium Hypersensitivity Effect of Leukocyte- and Platelet-Rich Fibrin in Postoperative Recovery Following Impacted Mandibular Third Molar Surgery: A Split Mouth Study Comparison of Shear Bond Strength and Adhesive Remnant Index of Two Different Primers in Dry and Wet Conditions An Overview of Basic Concepts of Finite Element Analysis and Its Applications in Orthodontics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1