一种用于临床前放疗研究的高性能机载小动物PET

Xinyi Cheng, K. Hu, Dongxu Yang, Y. Shao
{"title":"一种用于临床前放疗研究的高性能机载小动物PET","authors":"Xinyi Cheng, K. Hu, Dongxu Yang, Y. Shao","doi":"10.1109/NSS/MIC42677.2020.9507964","DOIUrl":null,"url":null,"abstract":"We have developed and evaluated a prototype animal PET dedicated for PET/CT/RT. It consists of 12 detectors configured in a dodecagon; each panel has a 30x30 array of 1x1x20 mm3 LYSO scintillators with each end of the scintillator array optically connected to Silicon Photomultiplier (SiPM) arrays for depth-of-interaction (DOI) measurement. The trans-axial and axial field-of-view (FOV) are ~10 cm in diameter and 3.5 cm long. PCB and FPGA based detector readout and processing electronics has been developed. Preliminary system and imaging performances were evaluated with a Na-22 point source and a F-18 ultra-micro hot-rod phantom. The energy, DOI, and coincidence timing resolutions of the system are around 23%, 3.2 mm, and 4.88 ns, respectively. The measured system sensitivity is ~2.2% at the center of FOV, and the image resolution measured from the reconstructed point source images over the FOV ranges from 0.77 to 1.03 mm (mean 0.83 mm). Hot-rods with diameters from 1.0 to 2.4 mm are well separated on the reconstructed phantom image when DOI is applied.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"78 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A High-performance Onboard Small Animal PET for Preclinical Radiotherapy Research\",\"authors\":\"Xinyi Cheng, K. Hu, Dongxu Yang, Y. Shao\",\"doi\":\"10.1109/NSS/MIC42677.2020.9507964\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have developed and evaluated a prototype animal PET dedicated for PET/CT/RT. It consists of 12 detectors configured in a dodecagon; each panel has a 30x30 array of 1x1x20 mm3 LYSO scintillators with each end of the scintillator array optically connected to Silicon Photomultiplier (SiPM) arrays for depth-of-interaction (DOI) measurement. The trans-axial and axial field-of-view (FOV) are ~10 cm in diameter and 3.5 cm long. PCB and FPGA based detector readout and processing electronics has been developed. Preliminary system and imaging performances were evaluated with a Na-22 point source and a F-18 ultra-micro hot-rod phantom. The energy, DOI, and coincidence timing resolutions of the system are around 23%, 3.2 mm, and 4.88 ns, respectively. The measured system sensitivity is ~2.2% at the center of FOV, and the image resolution measured from the reconstructed point source images over the FOV ranges from 0.77 to 1.03 mm (mean 0.83 mm). Hot-rods with diameters from 1.0 to 2.4 mm are well separated on the reconstructed phantom image when DOI is applied.\",\"PeriodicalId\":6760,\"journal\":{\"name\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"volume\":\"78 1\",\"pages\":\"1-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSS/MIC42677.2020.9507964\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSS/MIC42677.2020.9507964","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们已经开发并评估了一种用于PET/CT/RT的动物PET原型。它由12个探测器组成,呈十二角形;每个面板都有一个30x30的1x1x20mm3的LYSO闪烁体阵列,闪烁体阵列的每一端光学连接到硅光电倍增管(SiPM)阵列,用于相互作用深度(DOI)测量。跨轴和轴向视场(FOV)直径约10厘米,长3.5厘米。基于PCB和FPGA的检测器读出和处理电子器件已经开发出来。采用Na-22点源和F-18超微热杆模体对系统和成像性能进行了初步评估。系统的能量分辨率约为23%,DOI约为3.2 mm,符合时序分辨率约为4.88 ns。在视场中心测得的系统灵敏度为~2.2%,在视场中心测得的重构点源图像分辨率范围为0.77 ~ 1.03 mm(平均0.83 mm)。当应用DOI时,直径为1.0 ~ 2.4 mm的热棒在重建的幻影图像上分离得很好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A High-performance Onboard Small Animal PET for Preclinical Radiotherapy Research
We have developed and evaluated a prototype animal PET dedicated for PET/CT/RT. It consists of 12 detectors configured in a dodecagon; each panel has a 30x30 array of 1x1x20 mm3 LYSO scintillators with each end of the scintillator array optically connected to Silicon Photomultiplier (SiPM) arrays for depth-of-interaction (DOI) measurement. The trans-axial and axial field-of-view (FOV) are ~10 cm in diameter and 3.5 cm long. PCB and FPGA based detector readout and processing electronics has been developed. Preliminary system and imaging performances were evaluated with a Na-22 point source and a F-18 ultra-micro hot-rod phantom. The energy, DOI, and coincidence timing resolutions of the system are around 23%, 3.2 mm, and 4.88 ns, respectively. The measured system sensitivity is ~2.2% at the center of FOV, and the image resolution measured from the reconstructed point source images over the FOV ranges from 0.77 to 1.03 mm (mean 0.83 mm). Hot-rods with diameters from 1.0 to 2.4 mm are well separated on the reconstructed phantom image when DOI is applied.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance of Dual-Ended Readout PET Detectors Based on SiPMs with Different Microcell Sizes Neural Network-based Inter-crystal Scatter Event Positioning in a PET System Design Based on 3D Position Sensitive Detectors An e-LINAC driven PGNAA system for concealed drug inspection Design of a Multi-Technology Pre-Clinical SPECT System Comprehensive Simulation and Design of 3D Silicon Sensors for Enhanced Timing Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1