不同情况下旅舍室内空气质素的本底浓度

N. R. Awang, Amzar Shahir Ridzuan, Mohamad Haris Zainol
{"title":"不同情况下旅舍室内空气质素的本底浓度","authors":"N. R. Awang, Amzar Shahir Ridzuan, Mohamad Haris Zainol","doi":"10.47253/JTRSS.V6I2.571","DOIUrl":null,"url":null,"abstract":"The indoor air pollutants in student hostel room during eight different conditions were evaluated.One minute interval of TVOC, CO2, CO, O3 concentrations, temperature and relative humidity weremeasured inside a vacant hostel room of Universiti Sains Malaysia. Four fan speeds of 0, 1, 3 and5 and the installed window being open and close were selected as the basis to determine thecondition inside the hostel room. Result suggested that the concentrations of indoor air pollutantswere below the maximum permissible values outlined by Industrial Code of Practice on Indoor AirPollutants except for O3, with maximum concentration are 576 ppb (TVOC), 666 ppm (CO2), 4.4ppm (CO) and 90 ppb (O3). The hourly trend of TVOC and CO2 concentrations with peakconcentrations were observed in the morning (8 a.m.) due to outdoor traffic emission which greatlyinfluenced the indoor pollutants variation. Meanwhile, O3 showed some delay in time to reach peakconcentrations that were observed at 4 p.m. and 5 p.m. Result indicate that the conditions set upwere incapable in the regulation of indoor pollutants variation since these pollutants are moredependent with the source of emission and destruction factors.","PeriodicalId":17457,"journal":{"name":"Journal of Tropical Resources and Sustainable Science (JTRSS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Background concentration of indoor air quality in hostel rooms during varying conditions\",\"authors\":\"N. R. Awang, Amzar Shahir Ridzuan, Mohamad Haris Zainol\",\"doi\":\"10.47253/JTRSS.V6I2.571\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The indoor air pollutants in student hostel room during eight different conditions were evaluated.One minute interval of TVOC, CO2, CO, O3 concentrations, temperature and relative humidity weremeasured inside a vacant hostel room of Universiti Sains Malaysia. Four fan speeds of 0, 1, 3 and5 and the installed window being open and close were selected as the basis to determine thecondition inside the hostel room. Result suggested that the concentrations of indoor air pollutantswere below the maximum permissible values outlined by Industrial Code of Practice on Indoor AirPollutants except for O3, with maximum concentration are 576 ppb (TVOC), 666 ppm (CO2), 4.4ppm (CO) and 90 ppb (O3). The hourly trend of TVOC and CO2 concentrations with peakconcentrations were observed in the morning (8 a.m.) due to outdoor traffic emission which greatlyinfluenced the indoor pollutants variation. Meanwhile, O3 showed some delay in time to reach peakconcentrations that were observed at 4 p.m. and 5 p.m. Result indicate that the conditions set upwere incapable in the regulation of indoor pollutants variation since these pollutants are moredependent with the source of emission and destruction factors.\",\"PeriodicalId\":17457,\"journal\":{\"name\":\"Journal of Tropical Resources and Sustainable Science (JTRSS)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Tropical Resources and Sustainable Science (JTRSS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47253/JTRSS.V6I2.571\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Tropical Resources and Sustainable Science (JTRSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47253/JTRSS.V6I2.571","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对8种不同条件下的学生宿舍室内空气污染物进行了评价。在马来西亚圣士大学一个空置的宿舍房间内,每隔一分钟测量TVOC、CO2、CO、O3浓度、温度和相对湿度。风机转速为0、1、3和5,安装的窗户是打开和关闭的,这是确定宿舍房间内状况的依据。结果表明,除O3外,室内空气污染物浓度均低于《室内空气污染物工业操作规程》规定的最大允制值,最大浓度分别为576 ppb (TVOC)、666 ppm (CO2)、4.4ppm (CO)和90 ppb (O3)。TVOC和CO2浓度的逐小时变化趋势主要出现在上午(8点),室外交通排放对室内污染物变化有较大影响。与此同时,臭氧在下午4点和5点达到峰值的时间有所延迟。结果表明,由于室内污染物对排放源和破坏因子的依赖性较强,所设置的条件无法调节室内污染物的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Background concentration of indoor air quality in hostel rooms during varying conditions
The indoor air pollutants in student hostel room during eight different conditions were evaluated.One minute interval of TVOC, CO2, CO, O3 concentrations, temperature and relative humidity weremeasured inside a vacant hostel room of Universiti Sains Malaysia. Four fan speeds of 0, 1, 3 and5 and the installed window being open and close were selected as the basis to determine thecondition inside the hostel room. Result suggested that the concentrations of indoor air pollutantswere below the maximum permissible values outlined by Industrial Code of Practice on Indoor AirPollutants except for O3, with maximum concentration are 576 ppb (TVOC), 666 ppm (CO2), 4.4ppm (CO) and 90 ppb (O3). The hourly trend of TVOC and CO2 concentrations with peakconcentrations were observed in the morning (8 a.m.) due to outdoor traffic emission which greatlyinfluenced the indoor pollutants variation. Meanwhile, O3 showed some delay in time to reach peakconcentrations that were observed at 4 p.m. and 5 p.m. Result indicate that the conditions set upwere incapable in the regulation of indoor pollutants variation since these pollutants are moredependent with the source of emission and destruction factors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Snails (Mollusca) diversity and its distribution in various type of microhabitats Assessment of flora diversity and population structure in Lagos-Sagamu-Abeokuta Expressway, Southwestern Nigeria Assessment of certain micronutrients (Zn, Fe, Ni, and Se) in some herbal snuff stocks consumed in Sokoto, Nigeria Physicochemical and antioxidant properties of commercial shrimp paste in Besut market Determinant of Extension Agent’s Skills Towards Work Performance As Perceived By Productive Cocoa Farmers In Malaysia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1