具有皮秒精度和准确度的双向时间传递

J. Kodet, I. Procházka, J. Blažej, P. Pánek, U. Schreiber, P. Lauber
{"title":"具有皮秒精度和准确度的双向时间传递","authors":"J. Kodet, I. Procházka, J. Blažej, P. Pánek, U. Schreiber, P. Lauber","doi":"10.1109/EFTF.2012.6502429","DOIUrl":null,"url":null,"abstract":"The first results of a two way time transfer between two timing devices over modest distances with sub-ps precision and a few ps accuracy were the major tasks of this work. The two way time transfer scheme employing a single coaxial cable was applied. Based on our previous results we have designed and constructed a timing device which allows registration of Times of Arrivals of pulses with sub-ps timing resolution, linearity, and stability. The concept of the timing devices enables to carry out time tagging of pulses of interest in parallel to the comparison of the time scales of these timing devices. The two timing devices were located in different laboratories and buildings within one institution. The common clock 5 MHz was referenced to a Cesium clock. The analysis of systematic errors contribution shows that the accuracy of the time transfer well below 10 ps may be achieved. The time transfer was accomplished over distances of the order of hundreds of meters. The main limitation for longer distances is the quality of the coaxial cable used for time transfer together with the amount of radiofrequency interference within the experiment.","PeriodicalId":6409,"journal":{"name":"2012 European Frequency and Time Forum","volume":"66 3 1","pages":"483-487"},"PeriodicalIF":0.0000,"publicationDate":"2012-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Two way time transfer with picoseconds precision and accuracy\",\"authors\":\"J. Kodet, I. Procházka, J. Blažej, P. Pánek, U. Schreiber, P. Lauber\",\"doi\":\"10.1109/EFTF.2012.6502429\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The first results of a two way time transfer between two timing devices over modest distances with sub-ps precision and a few ps accuracy were the major tasks of this work. The two way time transfer scheme employing a single coaxial cable was applied. Based on our previous results we have designed and constructed a timing device which allows registration of Times of Arrivals of pulses with sub-ps timing resolution, linearity, and stability. The concept of the timing devices enables to carry out time tagging of pulses of interest in parallel to the comparison of the time scales of these timing devices. The two timing devices were located in different laboratories and buildings within one institution. The common clock 5 MHz was referenced to a Cesium clock. The analysis of systematic errors contribution shows that the accuracy of the time transfer well below 10 ps may be achieved. The time transfer was accomplished over distances of the order of hundreds of meters. The main limitation for longer distances is the quality of the coaxial cable used for time transfer together with the amount of radiofrequency interference within the experiment.\",\"PeriodicalId\":6409,\"journal\":{\"name\":\"2012 European Frequency and Time Forum\",\"volume\":\"66 3 1\",\"pages\":\"483-487\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 European Frequency and Time Forum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EFTF.2012.6502429\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 European Frequency and Time Forum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EFTF.2012.6502429","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文的主要任务是在两个定时装置之间以亚ps精度和几ps精度在适度距离上进行双向时间传递的第一个结果。采用单同轴电缆的双向时间传输方案。基于我们之前的结果,我们设计并构建了一个定时装置,该装置允许以sub-ps定时分辨率,线性度和稳定性登记脉冲的到达时间。定时装置的概念使我们能够对感兴趣的脉冲进行时间标记,同时对这些定时装置的时间尺度进行比较。这两个定时装置位于同一机构的不同实验室和建筑物中。5兆赫的普通时钟参考了铯原子钟。系统误差贡献分析表明,可以实现远低于10ps的时间传递精度。时间传递是在几百米左右的距离上完成的。较长距离的主要限制是用于时间传输的同轴电缆的质量以及实验中射频干扰的数量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Two way time transfer with picoseconds precision and accuracy
The first results of a two way time transfer between two timing devices over modest distances with sub-ps precision and a few ps accuracy were the major tasks of this work. The two way time transfer scheme employing a single coaxial cable was applied. Based on our previous results we have designed and constructed a timing device which allows registration of Times of Arrivals of pulses with sub-ps timing resolution, linearity, and stability. The concept of the timing devices enables to carry out time tagging of pulses of interest in parallel to the comparison of the time scales of these timing devices. The two timing devices were located in different laboratories and buildings within one institution. The common clock 5 MHz was referenced to a Cesium clock. The analysis of systematic errors contribution shows that the accuracy of the time transfer well below 10 ps may be achieved. The time transfer was accomplished over distances of the order of hundreds of meters. The main limitation for longer distances is the quality of the coaxial cable used for time transfer together with the amount of radiofrequency interference within the experiment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Characterization of compact CPT clocks based on a Cs-Ne microcell Iodine based optical frequency reference with 10−15 stability On the impact of Group Delay Variations on GNSS time and frequency transfer T2L2 : Ground to ground Time Transfer Inter-comparison of the UTC time transfer links
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1