氯碱工业用近饱和岩盐溶液中微量铝的光度法测定

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2023-06-01 DOI:10.3311/ppch.22051
Benjámin Csorba, L. Farkas, Andrea Mihalkó, R. Z. Boros, I. Gresits
{"title":"氯碱工业用近饱和岩盐溶液中微量铝的光度法测定","authors":"Benjámin Csorba, L. Farkas, Andrea Mihalkó, R. Z. Boros, I. Gresits","doi":"10.3311/ppch.22051","DOIUrl":null,"url":null,"abstract":"The previously widespread mercury cell technology in chlorine production has now been replaced by more environmentally friendly membrane cell electrolysis which is a Best Available Techniques (BAT) technology. However, this requires a much cleaner brine containing contaminants (Al, Ca, Mg, etc.) in the order of ng/g at most. For this reason, it’s very important to detect trace amounts of aluminum in concentrated saline media in the simplest and fastest way. To the best of our knowledge, no one has previously developed a spectrophotometric method capable of detecting aluminum in ionic forms selectively in the order of ng/g in concentrated saline media, without any preconcentration or separation step. Our advanced analytical method provides an opportunity for this. During the analytical procedure, a colored complex ion is formed from the dissolved aluminum content of the sample with eriochrome cyanine R (ECR) ligand in buffered pH medium. The sensitivity of the measurement is increased by adding quaternary ammonium salt. The colored complex ion is formed in 15 minutes, then the absorbance measurement can be performed for 90 minutes. The effect of rock salt interference was eliminated by proper calibration. In our work the dependence of the signal on temperature, pH, time elapsed after the addition of reactants, the dosing sequence, the salinity of the medium was examined, furthermore, we studied which wavelength-absorbance values give the best fit (highest R2 value) and the highest sensitivity in case of linear calibration. Surprisingly, increasing the salinity significantly improves the sensitivity of the measurement.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Photometric Determination of Trace Amounts of Aluminum in Nearly Saturated Rock Salt Solutions Used by Chlor-alkali Industry\",\"authors\":\"Benjámin Csorba, L. Farkas, Andrea Mihalkó, R. Z. Boros, I. Gresits\",\"doi\":\"10.3311/ppch.22051\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The previously widespread mercury cell technology in chlorine production has now been replaced by more environmentally friendly membrane cell electrolysis which is a Best Available Techniques (BAT) technology. However, this requires a much cleaner brine containing contaminants (Al, Ca, Mg, etc.) in the order of ng/g at most. For this reason, it’s very important to detect trace amounts of aluminum in concentrated saline media in the simplest and fastest way. To the best of our knowledge, no one has previously developed a spectrophotometric method capable of detecting aluminum in ionic forms selectively in the order of ng/g in concentrated saline media, without any preconcentration or separation step. Our advanced analytical method provides an opportunity for this. During the analytical procedure, a colored complex ion is formed from the dissolved aluminum content of the sample with eriochrome cyanine R (ECR) ligand in buffered pH medium. The sensitivity of the measurement is increased by adding quaternary ammonium salt. The colored complex ion is formed in 15 minutes, then the absorbance measurement can be performed for 90 minutes. The effect of rock salt interference was eliminated by proper calibration. In our work the dependence of the signal on temperature, pH, time elapsed after the addition of reactants, the dosing sequence, the salinity of the medium was examined, furthermore, we studied which wavelength-absorbance values give the best fit (highest R2 value) and the highest sensitivity in case of linear calibration. Surprisingly, increasing the salinity significantly improves the sensitivity of the measurement.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3311/ppch.22051\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3311/ppch.22051","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

以前在氯气生产中广泛使用的汞电池技术现在已经被更环保的膜电池电解技术所取代,这是一种最佳可用技术(BAT)技术。然而,这需要更清洁的盐水,其中含有最多纳克/克量级的污染物(Al, Ca, Mg等)。因此,用最简单、最快速的方法检测浓盐水介质中的微量铝是非常重要的。据我们所知,以前还没有人开发出一种分光光度法,能够在浓盐水介质中选择性地以ng/g的顺序检测离子形式的铝,而不需要任何预浓缩或分离步骤。我们先进的分析方法为这提供了机会。在分析过程中,在缓冲pH介质中,用eriochrome cyanine R (ECR)配体溶解样品的铝含量形成有色络合离子。加入季铵盐可提高测量灵敏度。15分钟形成有色络合离子,90分钟可进行吸光度测量。通过适当的校正,消除了岩盐干扰的影响。在我们的工作中,我们考察了信号对温度、pH值、添加反应物后的时间、给药顺序、介质盐度的依赖关系,并研究了在线性校准情况下,哪些波长-吸光度值具有最佳拟合(最高R2值)和最高灵敏度。令人惊讶的是,增加盐度显著提高了测量的灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Photometric Determination of Trace Amounts of Aluminum in Nearly Saturated Rock Salt Solutions Used by Chlor-alkali Industry
The previously widespread mercury cell technology in chlorine production has now been replaced by more environmentally friendly membrane cell electrolysis which is a Best Available Techniques (BAT) technology. However, this requires a much cleaner brine containing contaminants (Al, Ca, Mg, etc.) in the order of ng/g at most. For this reason, it’s very important to detect trace amounts of aluminum in concentrated saline media in the simplest and fastest way. To the best of our knowledge, no one has previously developed a spectrophotometric method capable of detecting aluminum in ionic forms selectively in the order of ng/g in concentrated saline media, without any preconcentration or separation step. Our advanced analytical method provides an opportunity for this. During the analytical procedure, a colored complex ion is formed from the dissolved aluminum content of the sample with eriochrome cyanine R (ECR) ligand in buffered pH medium. The sensitivity of the measurement is increased by adding quaternary ammonium salt. The colored complex ion is formed in 15 minutes, then the absorbance measurement can be performed for 90 minutes. The effect of rock salt interference was eliminated by proper calibration. In our work the dependence of the signal on temperature, pH, time elapsed after the addition of reactants, the dosing sequence, the salinity of the medium was examined, furthermore, we studied which wavelength-absorbance values give the best fit (highest R2 value) and the highest sensitivity in case of linear calibration. Surprisingly, increasing the salinity significantly improves the sensitivity of the measurement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Management of Cholesteatoma: Hearing Rehabilitation. Congenital Cholesteatoma. Evaluation of Cholesteatoma. Management of Cholesteatoma: Extension Beyond Middle Ear/Mastoid. Recidivism and Recurrence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1