{"title":"气相色谱- fid验证了尿袋中环氧乙烷的检测和定量方法","authors":"J. F. Rodrigues, Juliana Alves da Silva, R. P. Medeiros, J. V. S. D. A. Queiroz, Maria Roberta de Oliveira Pinto, S. Amoah, M. Fook","doi":"10.1590/s1517-707620230001.1334","DOIUrl":null,"url":null,"abstract":"The urine bag is a thermo-labile medical-hospital device used in clinical/surgical procedures in urine drainage and collection. As it is a thermolabile material, it is commonly sterilized by ethylene oxide, a highly toxic, mutagenic and carcinogenic cyclic ether gas. Currently, several countries require, through documents and standards, the quantification of ethylene oxide in medical and hospital devices. Thus, this work describes the development and validation of a method employed for the quantification of ethylene oxide (ETO) in urine bags. The method was developed based on the guidelines of ISO 10993-7, ANVISA and INMETRO. The work range, linearity, limits of detection and quantification, repeatability, intermediate precision and selectivity were evaluated. Statistical tools such as Levene's test, Grubbs, residual analysis, F-test of two variances, paired sample T test and ANOVA table, were also applied to evaluate the method. The linearity of the work range (10 – 400 mg.L -1 ) showed an adequate correlation coefficient (r > 0.9993), with a homoscedastic profile with absence of outliers while the limit of detection and quantification were 1,95 and 6,5 mg.L -1 respectively. After validation, 45 samples of urine bags of different batches were evaluated, which demonstrated levels of ETO below the limit of detection (1,95 mg.L -1 ). The results highlight a simple method that meets several regulations with a wide working range, high sensitivity and capability to quantify ETO not only in urine bags but also in other medical devices.","PeriodicalId":18246,"journal":{"name":"Matéria (Rio de Janeiro)","volume":"22 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A GC-FID validated method for detection and quantification of ethylene oxide in urine bags\",\"authors\":\"J. F. Rodrigues, Juliana Alves da Silva, R. P. Medeiros, J. V. S. D. A. Queiroz, Maria Roberta de Oliveira Pinto, S. Amoah, M. Fook\",\"doi\":\"10.1590/s1517-707620230001.1334\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The urine bag is a thermo-labile medical-hospital device used in clinical/surgical procedures in urine drainage and collection. As it is a thermolabile material, it is commonly sterilized by ethylene oxide, a highly toxic, mutagenic and carcinogenic cyclic ether gas. Currently, several countries require, through documents and standards, the quantification of ethylene oxide in medical and hospital devices. Thus, this work describes the development and validation of a method employed for the quantification of ethylene oxide (ETO) in urine bags. The method was developed based on the guidelines of ISO 10993-7, ANVISA and INMETRO. The work range, linearity, limits of detection and quantification, repeatability, intermediate precision and selectivity were evaluated. Statistical tools such as Levene's test, Grubbs, residual analysis, F-test of two variances, paired sample T test and ANOVA table, were also applied to evaluate the method. The linearity of the work range (10 – 400 mg.L -1 ) showed an adequate correlation coefficient (r > 0.9993), with a homoscedastic profile with absence of outliers while the limit of detection and quantification were 1,95 and 6,5 mg.L -1 respectively. After validation, 45 samples of urine bags of different batches were evaluated, which demonstrated levels of ETO below the limit of detection (1,95 mg.L -1 ). The results highlight a simple method that meets several regulations with a wide working range, high sensitivity and capability to quantify ETO not only in urine bags but also in other medical devices.\",\"PeriodicalId\":18246,\"journal\":{\"name\":\"Matéria (Rio de Janeiro)\",\"volume\":\"22 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Matéria (Rio de Janeiro)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/s1517-707620230001.1334\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Matéria (Rio de Janeiro)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/s1517-707620230001.1334","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A GC-FID validated method for detection and quantification of ethylene oxide in urine bags
The urine bag is a thermo-labile medical-hospital device used in clinical/surgical procedures in urine drainage and collection. As it is a thermolabile material, it is commonly sterilized by ethylene oxide, a highly toxic, mutagenic and carcinogenic cyclic ether gas. Currently, several countries require, through documents and standards, the quantification of ethylene oxide in medical and hospital devices. Thus, this work describes the development and validation of a method employed for the quantification of ethylene oxide (ETO) in urine bags. The method was developed based on the guidelines of ISO 10993-7, ANVISA and INMETRO. The work range, linearity, limits of detection and quantification, repeatability, intermediate precision and selectivity were evaluated. Statistical tools such as Levene's test, Grubbs, residual analysis, F-test of two variances, paired sample T test and ANOVA table, were also applied to evaluate the method. The linearity of the work range (10 – 400 mg.L -1 ) showed an adequate correlation coefficient (r > 0.9993), with a homoscedastic profile with absence of outliers while the limit of detection and quantification were 1,95 and 6,5 mg.L -1 respectively. After validation, 45 samples of urine bags of different batches were evaluated, which demonstrated levels of ETO below the limit of detection (1,95 mg.L -1 ). The results highlight a simple method that meets several regulations with a wide working range, high sensitivity and capability to quantify ETO not only in urine bags but also in other medical devices.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Rheological properties and engineering application of low-grade asphalt mixture Study on the performance and aging low temperature performance of GO / SBS modified asphalt Statistical optimization of fibre reinforced polymer concrete made with recycled plastic aggregates by central composite design Effects of Nb and V microalloying on the thermoplasticity of new martensitic low-density steels Influence of presaturated coconut fibre ash pellets in concrete
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1