{"title":"受永久传感器故障影响的离散事件系统故障诊断的验证与综合","authors":"Naoki Kanagawa, S. Takai","doi":"10.1109/ETFA.2014.7005103","DOIUrl":null,"url":null,"abstract":"In this paper, we consider a failure diagnosis problem for discrete event systems subject to permanent sensor failures. A notion of diagnosability subject to permanent sensor failures is introduced with respect to a certain nondeterministic observation mask. For its verification, we define an aggregated Mealy automaton with a deterministic and state-dependent observation mask. We show that diagnosability of the aggregated Mealy automaton is equivalent to diagnosability of the original system subject to permanent sensor failures. Then, we present a method for verifying diagnosability of the aggregated Mealy automaton. Moreover, we synthesize a diagnoser for the original system as an online diagnoser.","PeriodicalId":20477,"journal":{"name":"Proceedings of the 2014 IEEE Emerging Technology and Factory Automation (ETFA)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Verification and synthesis for failure diagnosis of discrete event systems subject to permanent sensor failures\",\"authors\":\"Naoki Kanagawa, S. Takai\",\"doi\":\"10.1109/ETFA.2014.7005103\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we consider a failure diagnosis problem for discrete event systems subject to permanent sensor failures. A notion of diagnosability subject to permanent sensor failures is introduced with respect to a certain nondeterministic observation mask. For its verification, we define an aggregated Mealy automaton with a deterministic and state-dependent observation mask. We show that diagnosability of the aggregated Mealy automaton is equivalent to diagnosability of the original system subject to permanent sensor failures. Then, we present a method for verifying diagnosability of the aggregated Mealy automaton. Moreover, we synthesize a diagnoser for the original system as an online diagnoser.\",\"PeriodicalId\":20477,\"journal\":{\"name\":\"Proceedings of the 2014 IEEE Emerging Technology and Factory Automation (ETFA)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2014 IEEE Emerging Technology and Factory Automation (ETFA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ETFA.2014.7005103\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2014 IEEE Emerging Technology and Factory Automation (ETFA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ETFA.2014.7005103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Verification and synthesis for failure diagnosis of discrete event systems subject to permanent sensor failures
In this paper, we consider a failure diagnosis problem for discrete event systems subject to permanent sensor failures. A notion of diagnosability subject to permanent sensor failures is introduced with respect to a certain nondeterministic observation mask. For its verification, we define an aggregated Mealy automaton with a deterministic and state-dependent observation mask. We show that diagnosability of the aggregated Mealy automaton is equivalent to diagnosability of the original system subject to permanent sensor failures. Then, we present a method for verifying diagnosability of the aggregated Mealy automaton. Moreover, we synthesize a diagnoser for the original system as an online diagnoser.