{"title":"用于髋关节假体的碳化物衍生碳 (CDC) 的体外摩擦腐蚀评估。","authors":"Yani Sun, Kyle Kinnerk, Tony Mirshed, Michael McNallan, Mathew Mathew","doi":"10.1080/17436753.2023.2241251","DOIUrl":null,"url":null,"abstract":"<p><p>Carbide-derived carbon (CDC) was previously proposed as a surface modification method for hip implant applications since it showed excellent tribocorrosion performance under open-circuit potential (OCP) conditions. Nonetheless, a systematic evaluation of CDC's tribocorrosion properties was still missing. Therefore, our objective is to test CDC's tribocorrosion performance under various electrochemical conditions and to identify the synergism between wear and corrosion. Based on the findings, the variations in OCP for CDC (0.626 mV) is smaller than Ti6Al4V (1.91 mV), and CDC showed lower induced current than T6Al4V for all potentials, suggesting CDC is more stable than Ti6Al4V under tribocorrosive conditions. Eventually, the weight loss of Ti6Al4V (50.662±5.19 μg) was found to be significantly higher than that of CDC (4.965±5.19 μg), which agrees with the electrochemical results. In summary, CDC showed better tribocorrosion performance than Ti6Al4V and was determined as an Antagonism regime.</p>","PeriodicalId":7224,"journal":{"name":"Advances in Applied Ceramics","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10723791/pdf/","citationCount":"0","resultStr":"{\"title\":\"In Vitro Tribocorrosion Evaluation of Carbide-derived Carbon (CDC) for Hip Implants.\",\"authors\":\"Yani Sun, Kyle Kinnerk, Tony Mirshed, Michael McNallan, Mathew Mathew\",\"doi\":\"10.1080/17436753.2023.2241251\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Carbide-derived carbon (CDC) was previously proposed as a surface modification method for hip implant applications since it showed excellent tribocorrosion performance under open-circuit potential (OCP) conditions. Nonetheless, a systematic evaluation of CDC's tribocorrosion properties was still missing. Therefore, our objective is to test CDC's tribocorrosion performance under various electrochemical conditions and to identify the synergism between wear and corrosion. Based on the findings, the variations in OCP for CDC (0.626 mV) is smaller than Ti6Al4V (1.91 mV), and CDC showed lower induced current than T6Al4V for all potentials, suggesting CDC is more stable than Ti6Al4V under tribocorrosive conditions. Eventually, the weight loss of Ti6Al4V (50.662±5.19 μg) was found to be significantly higher than that of CDC (4.965±5.19 μg), which agrees with the electrochemical results. In summary, CDC showed better tribocorrosion performance than Ti6Al4V and was determined as an Antagonism regime.</p>\",\"PeriodicalId\":7224,\"journal\":{\"name\":\"Advances in Applied Ceramics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10723791/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Applied Ceramics\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1080/17436753.2023.2241251\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"MATERIALS SCIENCE, CERAMICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Applied Ceramics","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1080/17436753.2023.2241251","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MATERIALS SCIENCE, CERAMICS","Score":null,"Total":0}
引用次数: 0

摘要

由于碳化物衍生碳(CDC)在开路电位(OCP)条件下显示出优异的摩擦腐蚀性能,因此以前曾被提议作为髋关节植入物的表面改性方法。然而,目前还没有对 CDC 的摩擦腐蚀性能进行系统的评估。因此,我们的目标是测试 CDC 在各种电化学条件下的摩擦腐蚀性能,并确定磨损和腐蚀之间的协同作用。根据研究结果,CDC 的 OCP 变化(0.626 mV)小于 Ti6Al4V(1.91 mV),而且在所有电位下,CDC 的感应电流均低于 T6Al4V,这表明在摩擦腐蚀条件下,CDC 比 Ti6Al4V 更稳定。最终,Ti6Al4V 的失重(50.662±5.19 μg)明显高于 CDC 的失重(4.965±5.19 μg),这与电化学结果一致。总之,CDC 比 Ti6Al4V 显示出更好的摩擦腐蚀性能,并被确定为拮抗体系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In Vitro Tribocorrosion Evaluation of Carbide-derived Carbon (CDC) for Hip Implants.

Carbide-derived carbon (CDC) was previously proposed as a surface modification method for hip implant applications since it showed excellent tribocorrosion performance under open-circuit potential (OCP) conditions. Nonetheless, a systematic evaluation of CDC's tribocorrosion properties was still missing. Therefore, our objective is to test CDC's tribocorrosion performance under various electrochemical conditions and to identify the synergism between wear and corrosion. Based on the findings, the variations in OCP for CDC (0.626 mV) is smaller than Ti6Al4V (1.91 mV), and CDC showed lower induced current than T6Al4V for all potentials, suggesting CDC is more stable than Ti6Al4V under tribocorrosive conditions. Eventually, the weight loss of Ti6Al4V (50.662±5.19 μg) was found to be significantly higher than that of CDC (4.965±5.19 μg), which agrees with the electrochemical results. In summary, CDC showed better tribocorrosion performance than Ti6Al4V and was determined as an Antagonism regime.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Advances in Applied Ceramics
Advances in Applied Ceramics 工程技术-材料科学:硅酸盐
CiteScore
4.40
自引率
4.50%
发文量
17
审稿时长
5.2 months
期刊介绍: Advances in Applied Ceramics: Structural, Functional and Bioceramics provides international coverage of high-quality research on functional ceramics, engineering ceramics and bioceramics.
期刊最新文献
Special Issue: ‘Advanced Ceramics and Coatings for Wear and Corrosion Applications’ Influences on the mechanical and physical properties of hot-press moulding alkali-activated slag (HP-FRAASC) composite with various fibers 3D-printed porous Al 2 O 3 membrane coated with hydrophilic modified titanium dioxide particles for large-flux oil/water separation Preparation of porous ceramsite from municipal sludge and its structure characteristics Gel-casting for manufacturing porous alumina ceramics with complex shapes for transpiration cooling
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1