氯吡格雷的监管建议:重点是验证可靠的生物分析方法及其在生物等效性研究中的应用

S. Dey, Kirti Kandhwal, Shabana Nazarudheen, Onkar Singh, S. Mukherjee, Sanjeev Mishra, S. Reyar, A. Khuroo, T. Monif
{"title":"氯吡格雷的监管建议:重点是验证可靠的生物分析方法及其在生物等效性研究中的应用","authors":"S. Dey, Kirti Kandhwal, Shabana Nazarudheen, Onkar Singh, S. Mukherjee, Sanjeev Mishra, S. Reyar, A. Khuroo, T. Monif","doi":"10.3109/10601333.2011.619540","DOIUrl":null,"url":null,"abstract":"A rapid, simple, and sensitive liquid chromatography tandem mass spectrometric (LC–MS/MS) method for the determination of clopidogrel in human plasma was developed and validated using clopidogrel-d4 as the internal standard (IS). The analyte and the IS were extracted from 500 µl aliquots of human plasma via solid phase extraction. The precursor to product ion transitions monitored for clopidogrel and IS were m/z 322.2 → 212.0 and 326.2 → 216.0, respectively. The method was fully validated for sensitivity, accuracy and precision, linearity, recovery, matrix effect, dilution integrity, and stability. The Linearity range was 20.4–10,772.6 pg/mL with mean correlation coefficient (r) ≥ 0.9977. The back conversion was also evaluated during method validation as per EMA recommendation. Results proved that clopidogrel was accurately and reliably estimated by the method without any evidence of back conversion of clopidogrel acid. The method was successfully applied to a bioequivalence study of 75 mg clopidogrel bisulfate tablet formulation in 32 healthy male volunteers under fasting conditions. The ratios of least-squares means (with 90% confidence intervals) for the pharmacokinetic parameters Cmax, AUC0–t and AUC0–α were 107.98% (94.52–123.35%), 100.25% (91.28–110.09%), and 100.49% (91.37–110.51%), respectively.","PeriodicalId":10446,"journal":{"name":"Clinical Research and Regulatory Affairs","volume":"41 1","pages":"87 - 95"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Regulatory recommendations for clopidogrel: Focus on validation of a reliable bioanalytical method and its application to a bioequivalence study\",\"authors\":\"S. Dey, Kirti Kandhwal, Shabana Nazarudheen, Onkar Singh, S. Mukherjee, Sanjeev Mishra, S. Reyar, A. Khuroo, T. Monif\",\"doi\":\"10.3109/10601333.2011.619540\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A rapid, simple, and sensitive liquid chromatography tandem mass spectrometric (LC–MS/MS) method for the determination of clopidogrel in human plasma was developed and validated using clopidogrel-d4 as the internal standard (IS). The analyte and the IS were extracted from 500 µl aliquots of human plasma via solid phase extraction. The precursor to product ion transitions monitored for clopidogrel and IS were m/z 322.2 → 212.0 and 326.2 → 216.0, respectively. The method was fully validated for sensitivity, accuracy and precision, linearity, recovery, matrix effect, dilution integrity, and stability. The Linearity range was 20.4–10,772.6 pg/mL with mean correlation coefficient (r) ≥ 0.9977. The back conversion was also evaluated during method validation as per EMA recommendation. Results proved that clopidogrel was accurately and reliably estimated by the method without any evidence of back conversion of clopidogrel acid. The method was successfully applied to a bioequivalence study of 75 mg clopidogrel bisulfate tablet formulation in 32 healthy male volunteers under fasting conditions. The ratios of least-squares means (with 90% confidence intervals) for the pharmacokinetic parameters Cmax, AUC0–t and AUC0–α were 107.98% (94.52–123.35%), 100.25% (91.28–110.09%), and 100.49% (91.37–110.51%), respectively.\",\"PeriodicalId\":10446,\"journal\":{\"name\":\"Clinical Research and Regulatory Affairs\",\"volume\":\"41 1\",\"pages\":\"87 - 95\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Research and Regulatory Affairs\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10601333.2011.619540\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Research and Regulatory Affairs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10601333.2011.619540","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

建立了一种快速、简便、灵敏的液相色谱串联质谱(LC-MS /MS)测定人血浆中氯吡格雷的方法,并以氯吡格雷-d4为内标(IS)进行了验证。分析物和IS通过固相萃取从500µl等分的人血浆中提取。氯吡格雷和IS的前体产物离子跃迁分别为m/z 322.2→212.0和326.2→216.0。方法的灵敏度、准确度和精密度、线性度、回收率、基质效应、稀释完整性和稳定性均得到了充分验证。线性范围为20.4 ~ 10,772.6 pg/mL,平均相关系数(r)≥0.9977。根据EMA建议,在方法验证期间也评估了反向转换。结果表明,该方法测定氯吡格雷准确可靠,无氯吡格雷酸反转化现象。该方法成功应用于32名健康男性志愿者在禁食条件下对75 mg硫酸氯吡格雷片剂配方进行生物等效性研究。药代动力学参数Cmax、AUC0 - t和AUC0 -α的最小二乘均值比值(置信区间为90%)分别为107.98%(94.52 ~ 123.35%)、100.25%(91.28 ~ 110.09%)和100.49%(91.37 ~ 110.51%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Regulatory recommendations for clopidogrel: Focus on validation of a reliable bioanalytical method and its application to a bioequivalence study
A rapid, simple, and sensitive liquid chromatography tandem mass spectrometric (LC–MS/MS) method for the determination of clopidogrel in human plasma was developed and validated using clopidogrel-d4 as the internal standard (IS). The analyte and the IS were extracted from 500 µl aliquots of human plasma via solid phase extraction. The precursor to product ion transitions monitored for clopidogrel and IS were m/z 322.2 → 212.0 and 326.2 → 216.0, respectively. The method was fully validated for sensitivity, accuracy and precision, linearity, recovery, matrix effect, dilution integrity, and stability. The Linearity range was 20.4–10,772.6 pg/mL with mean correlation coefficient (r) ≥ 0.9977. The back conversion was also evaluated during method validation as per EMA recommendation. Results proved that clopidogrel was accurately and reliably estimated by the method without any evidence of back conversion of clopidogrel acid. The method was successfully applied to a bioequivalence study of 75 mg clopidogrel bisulfate tablet formulation in 32 healthy male volunteers under fasting conditions. The ratios of least-squares means (with 90% confidence intervals) for the pharmacokinetic parameters Cmax, AUC0–t and AUC0–α were 107.98% (94.52–123.35%), 100.25% (91.28–110.09%), and 100.49% (91.37–110.51%), respectively.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Changes to protocol in the regulation of adverse drug reactions – historical and current European view Policy and regulations in light of the human body as a ‘superorganism’ containing multiple, intertwined symbiotic relationships Community pharmacists’ knowledge and perceptions on risk management plans in the Southern Region of Portugal Increasing the odds of effective drug development: Elevating regulatory affairs professionals to strategic partners Current regulatory challenges and approaches in the registration of herbal drugs in Europe
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1