Isna Lailatusholihah, Roto, A. Kuncaka, Ninik Triayu Susparini
{"title":"用紫外可见分光光度法等温蒸馏法验证标准品番茄叶片中硼的分析方法","authors":"Isna Lailatusholihah, Roto, A. Kuncaka, Ninik Triayu Susparini","doi":"10.22487/kovalen.2022.v8.i2.15955","DOIUrl":null,"url":null,"abstract":"Boron analysis by UV-Vis spectrophotometry has been developed through distilling triethoxy borane into the curcumin solution. In the distillation of ester borane, an esterification reaction occurs between borate and ethanol. Validation of isothermal distillation methods by UV-Vis spectrometry needs to be done to obtain specific, accurate, and reproducible results. The distillation for 24 hours at 25°C gave the optimum result. UV-Vis spectrophotometry wavelength was 535 nm. The standard curve was linear in the concentration range of 1-5 ppm (R2 = 0.9995) with a sensitivity of 0.0902 ppm-1, a limit of detection of 0.002±0.001 ppm, the limit of quantification of 0.006±0.001 ppm, and percent recovery of 88%.","PeriodicalId":17905,"journal":{"name":"KOVALEN: Jurnal Riset Kimia","volume":"5 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of Boron Analytical Methods on Standard Reference Material Tomato Leaves from NIST No. 1573a with Isothermal Distillation by UV-Vis Spectrophotometry\",\"authors\":\"Isna Lailatusholihah, Roto, A. Kuncaka, Ninik Triayu Susparini\",\"doi\":\"10.22487/kovalen.2022.v8.i2.15955\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Boron analysis by UV-Vis spectrophotometry has been developed through distilling triethoxy borane into the curcumin solution. In the distillation of ester borane, an esterification reaction occurs between borate and ethanol. Validation of isothermal distillation methods by UV-Vis spectrometry needs to be done to obtain specific, accurate, and reproducible results. The distillation for 24 hours at 25°C gave the optimum result. UV-Vis spectrophotometry wavelength was 535 nm. The standard curve was linear in the concentration range of 1-5 ppm (R2 = 0.9995) with a sensitivity of 0.0902 ppm-1, a limit of detection of 0.002±0.001 ppm, the limit of quantification of 0.006±0.001 ppm, and percent recovery of 88%.\",\"PeriodicalId\":17905,\"journal\":{\"name\":\"KOVALEN: Jurnal Riset Kimia\",\"volume\":\"5 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"KOVALEN: Jurnal Riset Kimia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22487/kovalen.2022.v8.i2.15955\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"KOVALEN: Jurnal Riset Kimia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22487/kovalen.2022.v8.i2.15955","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Validation of Boron Analytical Methods on Standard Reference Material Tomato Leaves from NIST No. 1573a with Isothermal Distillation by UV-Vis Spectrophotometry
Boron analysis by UV-Vis spectrophotometry has been developed through distilling triethoxy borane into the curcumin solution. In the distillation of ester borane, an esterification reaction occurs between borate and ethanol. Validation of isothermal distillation methods by UV-Vis spectrometry needs to be done to obtain specific, accurate, and reproducible results. The distillation for 24 hours at 25°C gave the optimum result. UV-Vis spectrophotometry wavelength was 535 nm. The standard curve was linear in the concentration range of 1-5 ppm (R2 = 0.9995) with a sensitivity of 0.0902 ppm-1, a limit of detection of 0.002±0.001 ppm, the limit of quantification of 0.006±0.001 ppm, and percent recovery of 88%.