{"title":"基于多准则决策的太阳能空气加热器混合人工粗糙度参数优化","authors":"Varun Goel, A. Dwivedi, A. Choudhary","doi":"10.1177/09576509231183037","DOIUrl":null,"url":null,"abstract":"Solar air heaters (SAHs) are widely accepted and used for drying and heating purposes. Numerous methodologies are available for augmentation of the performance of a SAH but the application of artificial roughness underside the absorber plate is reported to bean efficient one. This study aims to present the effects of using hybrid artificial roughness combining the transverse ribs along with discrete inclined ribs, on the thermo-hydraulic performance of roughened SAH. The response surface methodology (RSM) is utilized for the design of experiments to investigate the influence of relative roughness height (0.018 ≤ e/ D ≤ 0.036), relative roughness pitch (5 ≤ p/ e ≤ 15), attack angle (45° ≤ α ≤ 75°), and Reynolds number (1,900 ≤ Re ≤ 20,300) as input parameters. The empirical equations are developed for Nusselt number, friction factor, and thermo-hydraulic performance parameter based on the regression analysis. An integrated analytical hierarchy process-based weighted aggregated sum product assessment (AHP-WASPAS) method is used to evaluate an optimal parametric combination ( e/ D = 0.036, p/ e = 15, α = 75°, and Re = 20,300). The results are supported by the corresponding experimental outcomes. Also, the sensitivity analysis and rank reversal tests performed as qualitative assessment procedures for the results obtained from the proposed strategy. The proposed decision framework is reported to be very sensitive to several criteria weight fluctuations with maximum and least deviations of 15.41% and 2.56% for δWjp = +50% and δWjp = −10%, respectively. Further, the obtained results confirm the robustness of aopted decisional scheme with just one rank reversal.","PeriodicalId":20705,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"141 1","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2023-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Parametric optimization of hybrid artificial roughness used in solar air heaters using multiple criteria decision making techniques\",\"authors\":\"Varun Goel, A. Dwivedi, A. Choudhary\",\"doi\":\"10.1177/09576509231183037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Solar air heaters (SAHs) are widely accepted and used for drying and heating purposes. Numerous methodologies are available for augmentation of the performance of a SAH but the application of artificial roughness underside the absorber plate is reported to bean efficient one. This study aims to present the effects of using hybrid artificial roughness combining the transverse ribs along with discrete inclined ribs, on the thermo-hydraulic performance of roughened SAH. The response surface methodology (RSM) is utilized for the design of experiments to investigate the influence of relative roughness height (0.018 ≤ e/ D ≤ 0.036), relative roughness pitch (5 ≤ p/ e ≤ 15), attack angle (45° ≤ α ≤ 75°), and Reynolds number (1,900 ≤ Re ≤ 20,300) as input parameters. The empirical equations are developed for Nusselt number, friction factor, and thermo-hydraulic performance parameter based on the regression analysis. An integrated analytical hierarchy process-based weighted aggregated sum product assessment (AHP-WASPAS) method is used to evaluate an optimal parametric combination ( e/ D = 0.036, p/ e = 15, α = 75°, and Re = 20,300). The results are supported by the corresponding experimental outcomes. Also, the sensitivity analysis and rank reversal tests performed as qualitative assessment procedures for the results obtained from the proposed strategy. The proposed decision framework is reported to be very sensitive to several criteria weight fluctuations with maximum and least deviations of 15.41% and 2.56% for δWjp = +50% and δWjp = −10%, respectively. Further, the obtained results confirm the robustness of aopted decisional scheme with just one rank reversal.\",\"PeriodicalId\":20705,\"journal\":{\"name\":\"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy\",\"volume\":\"141 1\",\"pages\":\"\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-06-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/09576509231183037\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09576509231183037","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 3
摘要
太阳能空气加热器(SAHs)被广泛接受并用于干燥和加热目的。有许多方法可用于增强SAH的性能,但据报道,在吸收板下面应用人工粗糙度是一种有效的方法。本研究旨在展示混合人工粗糙度结合横向肋和离散斜肋对粗糙SAH热水力性能的影响。利用响应面法(RSM)进行实验设计,研究相对粗糙度高度(0.018≤e/ D≤0.036)、相对粗糙度间距(5≤p/ e≤15)、攻角(45°≤α≤75°)和雷诺数(1,900≤Re≤20,300)作为输入参数的影响。在回归分析的基础上,建立了Nusselt数、摩擦系数和热工性能参数的经验方程。采用基于综合层次分析法的加权总和产品评价(AHP-WASPAS)方法对最优参数组合(e/ D = 0.036, p/ e = 15, α = 75°,Re = 20,300)进行评价。所得结果得到了相应实验结果的支持。此外,灵敏度分析和等级反转测试作为从拟议策略中获得的结果的定性评估程序进行。据报道,所提出的决策框架对几个标准权重波动非常敏感,δWjp = +50%和δWjp = - 10%的最大和最小偏差分别为15.41%和2.56%。进一步,所得结果证实了所采用的决策方案在一次秩反转情况下的鲁棒性。
Parametric optimization of hybrid artificial roughness used in solar air heaters using multiple criteria decision making techniques
Solar air heaters (SAHs) are widely accepted and used for drying and heating purposes. Numerous methodologies are available for augmentation of the performance of a SAH but the application of artificial roughness underside the absorber plate is reported to bean efficient one. This study aims to present the effects of using hybrid artificial roughness combining the transverse ribs along with discrete inclined ribs, on the thermo-hydraulic performance of roughened SAH. The response surface methodology (RSM) is utilized for the design of experiments to investigate the influence of relative roughness height (0.018 ≤ e/ D ≤ 0.036), relative roughness pitch (5 ≤ p/ e ≤ 15), attack angle (45° ≤ α ≤ 75°), and Reynolds number (1,900 ≤ Re ≤ 20,300) as input parameters. The empirical equations are developed for Nusselt number, friction factor, and thermo-hydraulic performance parameter based on the regression analysis. An integrated analytical hierarchy process-based weighted aggregated sum product assessment (AHP-WASPAS) method is used to evaluate an optimal parametric combination ( e/ D = 0.036, p/ e = 15, α = 75°, and Re = 20,300). The results are supported by the corresponding experimental outcomes. Also, the sensitivity analysis and rank reversal tests performed as qualitative assessment procedures for the results obtained from the proposed strategy. The proposed decision framework is reported to be very sensitive to several criteria weight fluctuations with maximum and least deviations of 15.41% and 2.56% for δWjp = +50% and δWjp = −10%, respectively. Further, the obtained results confirm the robustness of aopted decisional scheme with just one rank reversal.
期刊介绍:
The Journal of Power and Energy, Part A of the Proceedings of the Institution of Mechanical Engineers, is dedicated to publishing peer-reviewed papers of high scientific quality on all aspects of the technology of energy conversion systems.