当代不同镍钛旋转系统对根管几何形状的影响

Yasmin Sobh, Mohsen M. Nour El Deen, A. Hashem
{"title":"当代不同镍钛旋转系统对根管几何形状的影响","authors":"Yasmin Sobh, Mohsen M. Nour El Deen, A. Hashem","doi":"10.21608/adjg.2021.30708.1266","DOIUrl":null,"url":null,"abstract":"Purpose: This study aimed to compare NiTi rotary systems of different wires namely; EdgeFiles, Profile GT series X (GTX) and ProTaper (PT) in terms of: canal transportation and centering ability. Materials and Methods: One hundred and twenty extracted human mandibular first molars were selected and randomly divided into two main groups (I&II) according to the ranges of curvature (60 teeth each), where group I: samples with 25o40o range of curvature and group II: samples with 45o60o range of curvature. Each group was subdivided into four subgroups according to the NiTi rotary system (15 teeth each): subgroup A: ProTaper, subgroup B: Profile GT Series X, subgroup C: EdgeFile X3 and subgroup D: EdgeFile X5. The root canals were scanned by i -CAT CBCT scanner before and after instrumentation at 3, 5 and 8 mm levels from the apex, to assess the canal transportation and centering ability. Results: The EdgeFile system produced the least canal transportation and remained more centered around the original canal than the other systems. While, PT system produced significantly the highest canal transportation and the least centered canal preparation than other systems. Conclusions: EdgeFile systems showed superior performance regarding maintenance of the original root canal curvature and centering ability than do other systems.","PeriodicalId":7493,"journal":{"name":"Al-Azhar Dental Journal for Girls","volume":"59 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effect of Different Contemporary Rotary Nickel Titanium Systems on Root Canal Geometry\",\"authors\":\"Yasmin Sobh, Mohsen M. Nour El Deen, A. Hashem\",\"doi\":\"10.21608/adjg.2021.30708.1266\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: This study aimed to compare NiTi rotary systems of different wires namely; EdgeFiles, Profile GT series X (GTX) and ProTaper (PT) in terms of: canal transportation and centering ability. Materials and Methods: One hundred and twenty extracted human mandibular first molars were selected and randomly divided into two main groups (I&II) according to the ranges of curvature (60 teeth each), where group I: samples with 25o40o range of curvature and group II: samples with 45o60o range of curvature. Each group was subdivided into four subgroups according to the NiTi rotary system (15 teeth each): subgroup A: ProTaper, subgroup B: Profile GT Series X, subgroup C: EdgeFile X3 and subgroup D: EdgeFile X5. The root canals were scanned by i -CAT CBCT scanner before and after instrumentation at 3, 5 and 8 mm levels from the apex, to assess the canal transportation and centering ability. Results: The EdgeFile system produced the least canal transportation and remained more centered around the original canal than the other systems. While, PT system produced significantly the highest canal transportation and the least centered canal preparation than other systems. Conclusions: EdgeFile systems showed superior performance regarding maintenance of the original root canal curvature and centering ability than do other systems.\",\"PeriodicalId\":7493,\"journal\":{\"name\":\"Al-Azhar Dental Journal for Girls\",\"volume\":\"59 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Al-Azhar Dental Journal for Girls\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21608/adjg.2021.30708.1266\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Azhar Dental Journal for Girls","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/adjg.2021.30708.1266","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的:比较不同金属丝的NiTi旋转系统;EdgeFiles, Profile GT系列X (GTX)和ProTaper (PT)在管道运输和定心能力方面。材料与方法:选取120颗拔除的人下颌第一磨牙,按曲率范围随机分为I组和II组(每组60颗),其中I组为曲率范围为250 ~ 400度的样本,II组为曲率范围为45 ~ 600度的样本。每组根据NiTi旋转系统再分为4个亚组(每个15颗牙):A亚组:ProTaper, B亚组:Profile GT Series X, C亚组:EdgeFile X3, D亚组:EdgeFile X5。使用i -CAT CBCT扫描器械前后根管距离根尖3、5和8 mm水平,评估根管运输和定心能力。结果:与其他系统相比,EdgeFile系统产生的根管移动最少,并且更集中在原根管周围。PT系统的根管移动量最大,中心根管预备量最小。结论:EdgeFile系统在维持根管曲率和对中能力方面优于其他系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Different Contemporary Rotary Nickel Titanium Systems on Root Canal Geometry
Purpose: This study aimed to compare NiTi rotary systems of different wires namely; EdgeFiles, Profile GT series X (GTX) and ProTaper (PT) in terms of: canal transportation and centering ability. Materials and Methods: One hundred and twenty extracted human mandibular first molars were selected and randomly divided into two main groups (I&II) according to the ranges of curvature (60 teeth each), where group I: samples with 25o40o range of curvature and group II: samples with 45o60o range of curvature. Each group was subdivided into four subgroups according to the NiTi rotary system (15 teeth each): subgroup A: ProTaper, subgroup B: Profile GT Series X, subgroup C: EdgeFile X3 and subgroup D: EdgeFile X5. The root canals were scanned by i -CAT CBCT scanner before and after instrumentation at 3, 5 and 8 mm levels from the apex, to assess the canal transportation and centering ability. Results: The EdgeFile system produced the least canal transportation and remained more centered around the original canal than the other systems. While, PT system produced significantly the highest canal transportation and the least centered canal preparation than other systems. Conclusions: EdgeFile systems showed superior performance regarding maintenance of the original root canal curvature and centering ability than do other systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Efficacy of Aloe vera in Treatment of Experimentally Induced Oral Lichenoid Reaction Evaluation of Local Versus Intravenous Administration of Adipose Tissue-Derived Stem Cells on Regeneration of Oral Epithelium of Chemotherapy Treated Rats The Influence of Different Implant Abutment Sizes on Fracture Resistance of Two Monolithic Ceramic Crown Systems Effect of Irradiation with 980-nm Diode Laser on the Microhardness of Young and Old Root Canal Dentin after Treatment with Chemical Solutions Evaluation of Occlusal Pressure Pattern and Dimensional Changes of the Lined Dentures Subjected to Microwave Disinfection Protocol
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1