{"title":"光氧疗法治疗足底疣疗效观察","authors":"N. V. Drozdova, Y. Alekseev, A. A. Lukovkina","doi":"10.37895/2071-8004-2023-27-1-53-56","DOIUrl":null,"url":null,"abstract":"Purpose: to describe a clinical case of successful application of light-oxygen therapy (LOT) in a patient with plantar warts.Material and methods. The publication presents a clinical case of the successful outcome after light-oxygen therapy in the absorption spectrum of endogenous oxygen with its transfer to the singlet state in a patient with plantar warts. Russian-made diode laser «Super Seb», manufactured by LLC New Surgical Technologies (Moscow, Russia) with wavelength near 1265 nm, laser power 0–3 W was used as a source of laser light. Radiation power was from 2.1 to 2.7 W. Power density – from 0.86 to 1.86 W/cm2. Exposure dose – from 258 to 558 J/cm2. No anesthesia was required. The maximal surface heating temperature during the procedure was 41 °C. Temperature was controlled with non–contact infrared thermometer ELARI SmartCare model YC-E13 (manufactured by Zhengyang Yuncheng Medical Technology Co. Ltd., China) to eliminate thermal damage. Laser sessions were twice a week with 3–4 day intervals.Results. Complete clinical remission was achieved after 14 LOT sessions.Conclusions. Light-oxygen therapy is an effective and safe procedure for patients with plantar warts.","PeriodicalId":10008,"journal":{"name":"中国激光医学杂志","volume":"2 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effectiveness of light-oxygen therapy in plantar warts (clinical observation)\",\"authors\":\"N. V. Drozdova, Y. Alekseev, A. A. Lukovkina\",\"doi\":\"10.37895/2071-8004-2023-27-1-53-56\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: to describe a clinical case of successful application of light-oxygen therapy (LOT) in a patient with plantar warts.Material and methods. The publication presents a clinical case of the successful outcome after light-oxygen therapy in the absorption spectrum of endogenous oxygen with its transfer to the singlet state in a patient with plantar warts. Russian-made diode laser «Super Seb», manufactured by LLC New Surgical Technologies (Moscow, Russia) with wavelength near 1265 nm, laser power 0–3 W was used as a source of laser light. Radiation power was from 2.1 to 2.7 W. Power density – from 0.86 to 1.86 W/cm2. Exposure dose – from 258 to 558 J/cm2. No anesthesia was required. The maximal surface heating temperature during the procedure was 41 °C. Temperature was controlled with non–contact infrared thermometer ELARI SmartCare model YC-E13 (manufactured by Zhengyang Yuncheng Medical Technology Co. Ltd., China) to eliminate thermal damage. Laser sessions were twice a week with 3–4 day intervals.Results. Complete clinical remission was achieved after 14 LOT sessions.Conclusions. Light-oxygen therapy is an effective and safe procedure for patients with plantar warts.\",\"PeriodicalId\":10008,\"journal\":{\"name\":\"中国激光医学杂志\",\"volume\":\"2 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国激光医学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.37895/2071-8004-2023-27-1-53-56\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国激光医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.37895/2071-8004-2023-27-1-53-56","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effectiveness of light-oxygen therapy in plantar warts (clinical observation)
Purpose: to describe a clinical case of successful application of light-oxygen therapy (LOT) in a patient with plantar warts.Material and methods. The publication presents a clinical case of the successful outcome after light-oxygen therapy in the absorption spectrum of endogenous oxygen with its transfer to the singlet state in a patient with plantar warts. Russian-made diode laser «Super Seb», manufactured by LLC New Surgical Technologies (Moscow, Russia) with wavelength near 1265 nm, laser power 0–3 W was used as a source of laser light. Radiation power was from 2.1 to 2.7 W. Power density – from 0.86 to 1.86 W/cm2. Exposure dose – from 258 to 558 J/cm2. No anesthesia was required. The maximal surface heating temperature during the procedure was 41 °C. Temperature was controlled with non–contact infrared thermometer ELARI SmartCare model YC-E13 (manufactured by Zhengyang Yuncheng Medical Technology Co. Ltd., China) to eliminate thermal damage. Laser sessions were twice a week with 3–4 day intervals.Results. Complete clinical remission was achieved after 14 LOT sessions.Conclusions. Light-oxygen therapy is an effective and safe procedure for patients with plantar warts.
期刊介绍:
The main columns of "Chinese Journal of Laser Medicine & Surgery" include treatises, which report the latest research results in basic research and clinical trials in the field of laser medicine; comprehensive reviews of the latest research progress in laser medicine at home and abroad. In addition, there are short reports and excerpts from foreign journals, conference news and other columns. The journal has published a large number of papers on basic research on laser medicine and applied research in various clinical subjects, aiming to play a positive role in promoting the application of laser in medicine and improving the level of laser medicine research.