基于实测与仿真的配电线路故障分析

Almina Džanan, S. Grebović, S. Smaka, V. Helac
{"title":"基于实测与仿真的配电线路故障分析","authors":"Almina Džanan, S. Grebović, S. Smaka, V. Helac","doi":"10.1109/INFOTEH53737.2022.9751337","DOIUrl":null,"url":null,"abstract":"Transient events, especially those related to the short circuit faults, are the main causes of power distribution lines outages. This paper is dedicated to the analysis of three-phase short circuit fault and its impact to the real 20 kV power distribution lines. One of the most important parts of Bosnia and Herzegovina's power system was monitored and analyzed. Short circuit currents and voltages were obtained by using the power distribution lines numerical protection system measurements from the moment of fault occurrence to the moment when the faulty line was switched off. Part of the power system of interest was modeled in EMTP-RV (Electromagnetic Transient Program - Restructured Version) software which is standardized software for transient analyses. Several simulations were conducted to perform fault analysis. Measured data and simulation results were compared.","PeriodicalId":6839,"journal":{"name":"2022 21st International Symposium INFOTEH-JAHORINA (INFOTEH)","volume":"12 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of Power Distribution Line Outage Based on Measurements and Simulations\",\"authors\":\"Almina Džanan, S. Grebović, S. Smaka, V. Helac\",\"doi\":\"10.1109/INFOTEH53737.2022.9751337\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transient events, especially those related to the short circuit faults, are the main causes of power distribution lines outages. This paper is dedicated to the analysis of three-phase short circuit fault and its impact to the real 20 kV power distribution lines. One of the most important parts of Bosnia and Herzegovina's power system was monitored and analyzed. Short circuit currents and voltages were obtained by using the power distribution lines numerical protection system measurements from the moment of fault occurrence to the moment when the faulty line was switched off. Part of the power system of interest was modeled in EMTP-RV (Electromagnetic Transient Program - Restructured Version) software which is standardized software for transient analyses. Several simulations were conducted to perform fault analysis. Measured data and simulation results were compared.\",\"PeriodicalId\":6839,\"journal\":{\"name\":\"2022 21st International Symposium INFOTEH-JAHORINA (INFOTEH)\",\"volume\":\"12 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 21st International Symposium INFOTEH-JAHORINA (INFOTEH)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INFOTEH53737.2022.9751337\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 21st International Symposium INFOTEH-JAHORINA (INFOTEH)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INFOTEH53737.2022.9751337","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

暂态事件,特别是与短路故障有关的暂态事件,是引起配电线路中断的主要原因。本文主要分析了三相短路故障及其对实际20kv配电线路的影响。对波斯尼亚和黑塞哥维那电力系统的一个最重要部分进行了监测和分析。利用配电线数值保护系统测量得到了从故障发生时刻到故障断开时刻的短路电流和电压。部分感兴趣的电力系统在EMTP-RV(电磁暂态程序-重构版)软件中建模,该软件是用于暂态分析的标准化软件。为了进行故障分析,进行了多次仿真。对实测数据和仿真结果进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of Power Distribution Line Outage Based on Measurements and Simulations
Transient events, especially those related to the short circuit faults, are the main causes of power distribution lines outages. This paper is dedicated to the analysis of three-phase short circuit fault and its impact to the real 20 kV power distribution lines. One of the most important parts of Bosnia and Herzegovina's power system was monitored and analyzed. Short circuit currents and voltages were obtained by using the power distribution lines numerical protection system measurements from the moment of fault occurrence to the moment when the faulty line was switched off. Part of the power system of interest was modeled in EMTP-RV (Electromagnetic Transient Program - Restructured Version) software which is standardized software for transient analyses. Several simulations were conducted to perform fault analysis. Measured data and simulation results were compared.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
PV system site selection using PVGIS and Fuzzy AHP Face Mask Detection Based on Machine Learning and Edge Computing Smart Production Systems: Methods and Application Analyzing the Effects of Abnormal Resonance Voltages using Artificial Neural Networks Real-Time Data Processing Techniques for a Scalable Spatial and Temporal Dimension Reduction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1