{"title":"用超极化129Xe nmr测量大鼠脑灌注:129Xe载体生物液体的研究","authors":"Guillaume Duhamel , Philippe Choquet , Emmanuelle Grillon , Jean-Louis Leviel , Anne Ziegler , André Constantinesco","doi":"10.1016/S1387-1609(01)01317-2","DOIUrl":null,"url":null,"abstract":"<div><p>The high xenon solubility in blood and tissues makes hyperpolarized <sup>129</sup>Xe a potential MR tracer for tissue perfusion studies. Two biocompatible fluids were studied with a view to be used as delivery media for hyperpolarized xenon injection: the carrier agents were <sup>129</sup>Xe micro-bubbles in Echovist (2–3 μm in diameter), and Intralipid <sup>129</sup>Xe suspension. Xenon chemical shifts and longitudinal relaxation time <em>T</em><sub>1</sub> were measured at 2.35 T in both fluids. Xenon chemical shift of the dissolved phase in Echovist was 204.1 ± 0.5 ppm from the micro-bubbles gas phase resonance data (0 ppm). Xenon <em>T</em><sub>1</sub> was 20.0 s in micro-bubbles in Echovist and 19.0 s for the dissolved phase. Xenon chemical shift in Intralipid was 194.6 ± 0.5 ppm. <em>T</em><sub>1</sub> was 15.2 ± 4.9 s (<em>n</em> = 5) in Intralipid 20 % and 20.9 ± 2.9 s (<em>n</em> = 4) in Intralipid 30 %. Using an intra-carotid injection of a small volume (0.15 mL) of hyperpolarized xenon dissolved in Intralipid 30 %, cerebral blood flow was measured in rats (160 ± 30 mL·(100 g)<sup>–1</sup>·min<sup>–1</sup>, <em>n</em> = 10). Rat brain xenon images were performed with 2-D projection–reconstruction pulse sequence, enabling regional blood flow measurements.</p></div>","PeriodicalId":100305,"journal":{"name":"Comptes Rendus de l'Académie des Sciences - Series IIC - Chemistry","volume":"4 10","pages":"Pages 789-794"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1387-1609(01)01317-2","citationCount":"3","resultStr":"{\"title\":\"Mesures de la perfusion cérébrale chez le rat à l’aide de la RMN du 129Xe hyperpolarisé : étude de fluides biologiques vecteurs du 129Xe\",\"authors\":\"Guillaume Duhamel , Philippe Choquet , Emmanuelle Grillon , Jean-Louis Leviel , Anne Ziegler , André Constantinesco\",\"doi\":\"10.1016/S1387-1609(01)01317-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The high xenon solubility in blood and tissues makes hyperpolarized <sup>129</sup>Xe a potential MR tracer for tissue perfusion studies. Two biocompatible fluids were studied with a view to be used as delivery media for hyperpolarized xenon injection: the carrier agents were <sup>129</sup>Xe micro-bubbles in Echovist (2–3 μm in diameter), and Intralipid <sup>129</sup>Xe suspension. Xenon chemical shifts and longitudinal relaxation time <em>T</em><sub>1</sub> were measured at 2.35 T in both fluids. Xenon chemical shift of the dissolved phase in Echovist was 204.1 ± 0.5 ppm from the micro-bubbles gas phase resonance data (0 ppm). Xenon <em>T</em><sub>1</sub> was 20.0 s in micro-bubbles in Echovist and 19.0 s for the dissolved phase. Xenon chemical shift in Intralipid was 194.6 ± 0.5 ppm. <em>T</em><sub>1</sub> was 15.2 ± 4.9 s (<em>n</em> = 5) in Intralipid 20 % and 20.9 ± 2.9 s (<em>n</em> = 4) in Intralipid 30 %. Using an intra-carotid injection of a small volume (0.15 mL) of hyperpolarized xenon dissolved in Intralipid 30 %, cerebral blood flow was measured in rats (160 ± 30 mL·(100 g)<sup>–1</sup>·min<sup>–1</sup>, <em>n</em> = 10). Rat brain xenon images were performed with 2-D projection–reconstruction pulse sequence, enabling regional blood flow measurements.</p></div>\",\"PeriodicalId\":100305,\"journal\":{\"name\":\"Comptes Rendus de l'Académie des Sciences - Series IIC - Chemistry\",\"volume\":\"4 10\",\"pages\":\"Pages 789-794\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S1387-1609(01)01317-2\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Comptes Rendus de l'Académie des Sciences - Series IIC - Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1387160901013172\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Comptes Rendus de l'Académie des Sciences - Series IIC - Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1387160901013172","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
摘要
氙在血液和组织中的高溶解度使超极化129Xe成为组织灌注研究的潜在MR示踪剂。研究了两种生物相容性液体作为超极化氙气注射的传递介质:载体为Echovist中的129Xe微泡(直径2 ~ 3 μm)和脂质内129Xe混悬液。在2.35 T时测量了两种流体中的氙化学位移和纵向弛豫时间T1。从微气泡气相共振数据(0 ppm)看,Echovist中氙溶解相的化学位移为204.1±0.5 ppm。氙气T1在Echovist微泡中为20.0 s,溶解相为19.0 s。脂肪内氙化学位移为194.6±0.5 ppm。脂内酯20%组T1为15.2±4.9 s (n = 5),脂内酯30%组T1为20.9±2.9 s (n = 4)。采用颈动脉内注射小体积(0.15 mL)溶解于脂内30%的超极化氙气,测量大鼠脑血流(160±30 mL·(100 g) -1·min-1, n = 10)。采用二维投影重建脉冲序列进行大鼠脑氙气成像,实现区域血流测量。
Mesures de la perfusion cérébrale chez le rat à l’aide de la RMN du 129Xe hyperpolarisé : étude de fluides biologiques vecteurs du 129Xe
The high xenon solubility in blood and tissues makes hyperpolarized 129Xe a potential MR tracer for tissue perfusion studies. Two biocompatible fluids were studied with a view to be used as delivery media for hyperpolarized xenon injection: the carrier agents were 129Xe micro-bubbles in Echovist (2–3 μm in diameter), and Intralipid 129Xe suspension. Xenon chemical shifts and longitudinal relaxation time T1 were measured at 2.35 T in both fluids. Xenon chemical shift of the dissolved phase in Echovist was 204.1 ± 0.5 ppm from the micro-bubbles gas phase resonance data (0 ppm). Xenon T1 was 20.0 s in micro-bubbles in Echovist and 19.0 s for the dissolved phase. Xenon chemical shift in Intralipid was 194.6 ± 0.5 ppm. T1 was 15.2 ± 4.9 s (n = 5) in Intralipid 20 % and 20.9 ± 2.9 s (n = 4) in Intralipid 30 %. Using an intra-carotid injection of a small volume (0.15 mL) of hyperpolarized xenon dissolved in Intralipid 30 %, cerebral blood flow was measured in rats (160 ± 30 mL·(100 g)–1·min–1, n = 10). Rat brain xenon images were performed with 2-D projection–reconstruction pulse sequence, enabling regional blood flow measurements.