电网变流器在改善电能质量中的鲁棒控制设计

K. Arulkumar, P. Manojbharath, S. Meikandasivam, D. Vijayakumar
{"title":"电网变流器在改善电能质量中的鲁棒控制设计","authors":"K. Arulkumar, P. Manojbharath, S. Meikandasivam, D. Vijayakumar","doi":"10.1109/TAPENERGY.2015.7229663","DOIUrl":null,"url":null,"abstract":"This paper focuses on grid connected PV inverter incorporating the improvement of power quality issues in its controller design. Proportional resonant (PR) controller is used for eliminating steady state error and for the fast dynamic response. A repetitive controller is used for tracking periodic reference signals and to compensate harmonic disturbances. To attain low THD and quick steady state process, feed forward approach is implemented in controller design. The stability of the voltage and current controller is examined in bode plot. Phase locked loop (PLL) synchronization technique with LCL filter is also examined. A single phase Grid connected 3Kw PV inverter is modeled and simulated in MATLAB/Simulink/PLECS environment with the accurate results in its waveform.","PeriodicalId":6552,"journal":{"name":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","volume":"90 1","pages":"460-465"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Robust control design of Grid power converters in improving power quality\",\"authors\":\"K. Arulkumar, P. Manojbharath, S. Meikandasivam, D. Vijayakumar\",\"doi\":\"10.1109/TAPENERGY.2015.7229663\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper focuses on grid connected PV inverter incorporating the improvement of power quality issues in its controller design. Proportional resonant (PR) controller is used for eliminating steady state error and for the fast dynamic response. A repetitive controller is used for tracking periodic reference signals and to compensate harmonic disturbances. To attain low THD and quick steady state process, feed forward approach is implemented in controller design. The stability of the voltage and current controller is examined in bode plot. Phase locked loop (PLL) synchronization technique with LCL filter is also examined. A single phase Grid connected 3Kw PV inverter is modeled and simulated in MATLAB/Simulink/PLECS environment with the accurate results in its waveform.\",\"PeriodicalId\":6552,\"journal\":{\"name\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"volume\":\"90 1\",\"pages\":\"460-465\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TAPENERGY.2015.7229663\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TAPENERGY.2015.7229663","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文以并网光伏逆变器为研究对象,在其控制器设计中考虑到改善电能质量的问题。采用比例谐振(PR)控制器来消除稳态误差和快速动态响应。重复控制器用于跟踪周期参考信号和补偿谐波干扰。为了实现低THD和快速的稳态过程,在控制器设计中采用了前馈方法。用波德图检验了电压电流控制器的稳定性。研究了采用LCL滤波器的锁相环同步技术。在MATLAB/Simulink/PLECS环境下对一种单相并网3Kw光伏逆变器进行了建模和仿真,得到了准确的波形结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Robust control design of Grid power converters in improving power quality
This paper focuses on grid connected PV inverter incorporating the improvement of power quality issues in its controller design. Proportional resonant (PR) controller is used for eliminating steady state error and for the fast dynamic response. A repetitive controller is used for tracking periodic reference signals and to compensate harmonic disturbances. To attain low THD and quick steady state process, feed forward approach is implemented in controller design. The stability of the voltage and current controller is examined in bode plot. Phase locked loop (PLL) synchronization technique with LCL filter is also examined. A single phase Grid connected 3Kw PV inverter is modeled and simulated in MATLAB/Simulink/PLECS environment with the accurate results in its waveform.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reduction of common mode voltage in three phase inverter A novel topology of forward-flyback PFC converter with constant on-time control Online benefit optimization in a liberalized/free microgrid market model UHVDC transmission with dedicated metallic return Bridgeless flyback converter for low power lighting application
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1