JT-60托卡马克聚变装置供电系统馈线中子管道流的估计

A. Sukegawa, Koichi Okuno
{"title":"JT-60托卡马克聚变装置供电系统馈线中子管道流的估计","authors":"A. Sukegawa, Koichi Okuno","doi":"10.15669/PNST.6.95","DOIUrl":null,"url":null,"abstract":"The estimation of neutron duct streaming with a feeder for the power supply system in a JT-60 Tokamak fusion device facility has been performed via neutoronics analysis using a simplified formula for the cylindrical duct streaming model and a suitable model based on the Monte Carlo technique. However, the safety margin is too large for the evaluation using a simplified formula in order to evaluate the neutron streaming of a duct with three feeders (each feeder of size 0.126 m × 0.357 m × 2 m) inside a cylindrical duct (0.8 m diameter × 2 m length in size). Further, a detailed evaluation of neutron streaming of a cylindrical duct with three feeders has not been performed in the facility. In this study, three-dimensional (3D) neutronics analysis using a real-model of the complex structured duct was performed to assess the safety margin of the simplified formula. It was confirmed that the neutron dose attenuation of the penetrating section in the duct using the simplified formula is approximately one order of magnitude larger than the real-model using the 3D calculation code.","PeriodicalId":20706,"journal":{"name":"Progress in Nuclear Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Estimation of neutron duct streaming with the feeder for the power supply system in the JT-60 tokamak fusion device facility\",\"authors\":\"A. Sukegawa, Koichi Okuno\",\"doi\":\"10.15669/PNST.6.95\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The estimation of neutron duct streaming with a feeder for the power supply system in a JT-60 Tokamak fusion device facility has been performed via neutoronics analysis using a simplified formula for the cylindrical duct streaming model and a suitable model based on the Monte Carlo technique. However, the safety margin is too large for the evaluation using a simplified formula in order to evaluate the neutron streaming of a duct with three feeders (each feeder of size 0.126 m × 0.357 m × 2 m) inside a cylindrical duct (0.8 m diameter × 2 m length in size). Further, a detailed evaluation of neutron streaming of a cylindrical duct with three feeders has not been performed in the facility. In this study, three-dimensional (3D) neutronics analysis using a real-model of the complex structured duct was performed to assess the safety margin of the simplified formula. It was confirmed that the neutron dose attenuation of the penetrating section in the duct using the simplified formula is approximately one order of magnitude larger than the real-model using the 3D calculation code.\",\"PeriodicalId\":20706,\"journal\":{\"name\":\"Progress in Nuclear Science and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Progress in Nuclear Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15669/PNST.6.95\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Nuclear Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15669/PNST.6.95","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

利用简化的圆柱形管道流模型公式和基于蒙特卡罗技术的合适模型,通过中子电子学分析对JT-60托卡马克聚变装置供电系统的中子管道流进行了估计。但是,在直径为0.8 m ×长度为2m的圆柱形风管中,采用简化公式评价具有3个给料器(每个给料器尺寸为0.126 m × 0.357 m × 2 m)的风管的中子流时,安全余量太大。此外,该设施还没有对带有三个进料器的圆柱形管道的中子流进行详细评估。在本研究中,使用复杂结构管道的实际模型进行了三维(3D)中子分析,以评估简化公式的安全裕度。用简化公式计算的导管穿透截面的中子剂量衰减比用三维计算程序计算的实际模型约大一个数量级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Estimation of neutron duct streaming with the feeder for the power supply system in the JT-60 tokamak fusion device facility
The estimation of neutron duct streaming with a feeder for the power supply system in a JT-60 Tokamak fusion device facility has been performed via neutoronics analysis using a simplified formula for the cylindrical duct streaming model and a suitable model based on the Monte Carlo technique. However, the safety margin is too large for the evaluation using a simplified formula in order to evaluate the neutron streaming of a duct with three feeders (each feeder of size 0.126 m × 0.357 m × 2 m) inside a cylindrical duct (0.8 m diameter × 2 m length in size). Further, a detailed evaluation of neutron streaming of a cylindrical duct with three feeders has not been performed in the facility. In this study, three-dimensional (3D) neutronics analysis using a real-model of the complex structured duct was performed to assess the safety margin of the simplified formula. It was confirmed that the neutron dose attenuation of the penetrating section in the duct using the simplified formula is approximately one order of magnitude larger than the real-model using the 3D calculation code.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Estimation of the characteristics of gamma-ray dose measurements with an experimental wireless dose monitoring system Proposal of framework for decision making of additional monitoring of eye lens dose for radiation workers Development of wide one-dimensional X-ray line sensor in backscatter X-ray imaging system for infrastructure inspection Evaluation of imaging plate measurement for activated indium as fast-neutron detector in large radiation field Development of a simultaneous evaluation method of radioactivity in soil and dose rate using CeBr3 and SrI2(Eu) scintillation detectors for environmental monitoring
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1