Sanwei Liu, Sangwook Chu, George E. Banis, L. Beardslee, R. Ghodssi
{"title":"用于高强度组织锚定的仿生倒刺微针","authors":"Sanwei Liu, Sangwook Chu, George E. Banis, L. Beardslee, R. Ghodssi","doi":"10.1109/MEMS46641.2020.9056127","DOIUrl":null,"url":null,"abstract":"We present a bioinspired tissue-anchoring technology enabled via direct laser writing (DLW). 3-D printed barbed microneedles, mimicking the parasitic spiny-headed worm, display excellent structural fidelity/resolution and demonstrate −0.6 mN penetration force and 25 mN pull-out force when characterized on porcine small intestine tissue. Compared to the state-of-the-art barbed microneedles, the results indicate a significant advancement with approximately two orders of magnitude lower penetration force and over ten-fold higher pull-out/penetration ratio (PPR). The ease of tissue penetration and strength of attachment characteristics allow a more passive anchoring mechanism, with lower actuation and power requirements, for use in minimally invasive gastrointestinal (GI) resident devices.","PeriodicalId":6776,"journal":{"name":"2020 IEEE 33rd International Conference on Micro Electro Mechanical Systems (MEMS)","volume":"15 1","pages":"885-888"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Biomimetic Barbed Microneedles for Highly Robust Tissue Anchoring\",\"authors\":\"Sanwei Liu, Sangwook Chu, George E. Banis, L. Beardslee, R. Ghodssi\",\"doi\":\"10.1109/MEMS46641.2020.9056127\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present a bioinspired tissue-anchoring technology enabled via direct laser writing (DLW). 3-D printed barbed microneedles, mimicking the parasitic spiny-headed worm, display excellent structural fidelity/resolution and demonstrate −0.6 mN penetration force and 25 mN pull-out force when characterized on porcine small intestine tissue. Compared to the state-of-the-art barbed microneedles, the results indicate a significant advancement with approximately two orders of magnitude lower penetration force and over ten-fold higher pull-out/penetration ratio (PPR). The ease of tissue penetration and strength of attachment characteristics allow a more passive anchoring mechanism, with lower actuation and power requirements, for use in minimally invasive gastrointestinal (GI) resident devices.\",\"PeriodicalId\":6776,\"journal\":{\"name\":\"2020 IEEE 33rd International Conference on Micro Electro Mechanical Systems (MEMS)\",\"volume\":\"15 1\",\"pages\":\"885-888\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 33rd International Conference on Micro Electro Mechanical Systems (MEMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MEMS46641.2020.9056127\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 33rd International Conference on Micro Electro Mechanical Systems (MEMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMS46641.2020.9056127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Biomimetic Barbed Microneedles for Highly Robust Tissue Anchoring
We present a bioinspired tissue-anchoring technology enabled via direct laser writing (DLW). 3-D printed barbed microneedles, mimicking the parasitic spiny-headed worm, display excellent structural fidelity/resolution and demonstrate −0.6 mN penetration force and 25 mN pull-out force when characterized on porcine small intestine tissue. Compared to the state-of-the-art barbed microneedles, the results indicate a significant advancement with approximately two orders of magnitude lower penetration force and over ten-fold higher pull-out/penetration ratio (PPR). The ease of tissue penetration and strength of attachment characteristics allow a more passive anchoring mechanism, with lower actuation and power requirements, for use in minimally invasive gastrointestinal (GI) resident devices.