{"title":"Penentuan Nilai Work Level Month (WLM) Maksimum Pekerja Pada Ruangan Berbahan Gipsum","authors":"Made Budi Setiono, Ngurah Sutapa, I. W. B. Sudarsan","doi":"10.29408/kpj.v3i1.1530","DOIUrl":null,"url":null,"abstract":"Research has been done to identify radioactive elements and determine  Work Level Month (WLM) values on workers in the sized room of 2m x 2m using gypsum material. Identification of radioactive elements in gipsum samples using Laser Induced Breakdown Spectroscopy (LIBS) methods and measurement of radiation dose in gypsum walls using surveymeter methods. Identification of radioactive elements to the LIBS method showed an element of Th, U, K were detected. The accumulated dose of radiation detected in the room using gypsum walls is (1,6993±0,0169) μSv and the accumulated dose of radiation detected in the room without gypsum walls is (0,5657±0,0292) μSv. WLM values from the room use a gypsum walls if workers work for 1 years is 0,9924 WLM, then it is still considered safe because it is still below the RR values that has been determined that is equal to 50 WLM.","PeriodicalId":82301,"journal":{"name":"Phi Kappa Phi journal","volume":"37 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Phi Kappa Phi journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29408/kpj.v3i1.1530","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究人员利用石膏材料在2米× 2米大小的房间内确定放射性元素并确定工作水平月(WLM)值。用激光诱导击穿光谱(LIBS)方法鉴定石膏样品中的放射性元素和用测量仪方法测量石膏壁中的辐射剂量。对放射性元素的鉴定以LIBS法显示,其中Th、U、K元素均被检出。使用石膏墙的房间检测到的累积辐射剂量为(1,6993±0,0169)μSv,不使用石膏墙的房间检测到的累积辐射剂量为(0,5657±0,0292)μSv。使用石膏墙的房间的WLM值如果工人工作1年是0.9924 WLM,那么它仍然被认为是安全的,因为它仍然低于已经确定的等于50 WLM的RR值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Penentuan Nilai Work Level Month (WLM) Maksimum Pekerja Pada Ruangan Berbahan Gipsum
Research has been done to identify radioactive elements and determine  Work Level Month (WLM) values on workers in the sized room of 2m x 2m using gypsum material. Identification of radioactive elements in gipsum samples using Laser Induced Breakdown Spectroscopy (LIBS) methods and measurement of radiation dose in gypsum walls using surveymeter methods. Identification of radioactive elements to the LIBS method showed an element of Th, U, K were detected. The accumulated dose of radiation detected in the room using gypsum walls is (1,6993±0,0169) μSv and the accumulated dose of radiation detected in the room without gypsum walls is (0,5657±0,0292) μSv. WLM values from the room use a gypsum walls if workers work for 1 years is 0,9924 WLM, then it is still considered safe because it is still below the RR values that has been determined that is equal to 50 WLM.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance Assessment in STEM-EDP Project for High School Students: Validity Aspect Analisis Perbandingan Nilai Efektivitas Koefisien Absorbsi pada Pelepah Pisang dan Eceng Gondok Penerapan Metode Pembelajaran Berbasis Masalah Terhadap Hasil Belajar Fisika Siswa Pengembangan Model Perkuliahan PAKDE (Presentasi, Audiensi, Konfirmasi, Diskusi Dan Evaluasi) berbasis Pendekatan Saintifik Pengembangan Alat Peraga Fisika Sederhana Berbahan Bekas Pakai pada Materi Gerak Lurus
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1