基于表面等离子体共振技术的多波长同步探测

Xiaojun Zhao, Zhen Wang, Ying Mu, Hanqi Zhang, Qinhan Jin
{"title":"基于表面等离子体共振技术的多波长同步探测","authors":"Xiaojun Zhao,&nbsp;Zhen Wang,&nbsp;Ying Mu,&nbsp;Hanqi Zhang,&nbsp;Qinhan Jin","doi":"10.1002/(SICI)1098-2728(2000)12:2<104::AID-LRA10>3.0.CO;2-4","DOIUrl":null,"url":null,"abstract":"<p>The present article covers a novel surface plasmon resonance (SPR) instrument based on simultaneous multiwavelength detection. The sensing principle of a traditional SPR device is based on fixing a discrete excitation wavelength and modulating the angle of incident light. The SPR-reflected spectra are shown in terms of reflected light intensity versus angle of incident light. The instrument presented here is designed on the basis of fixing the angle of incident light and measuring the change of resonant wavelength in the wavelength range of 400–800 nm. The SPR spectra are shown in terms of reflected light intensity versus wavelength of the incident light. The intensity of the reflected light is the minimum at the resonant wavelength. With the aid of the device, some chemical sensors and immunosensors, such as the thiolate chemical sensor, the fibrin immunosensor, and the albumin immunosensor were developed. The kinetic processes of formation of various sensing monolayers were studied in real time through observing the change of resonant wavelength. © 2000 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 12:104–107, 2000</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"12 2","pages":"104-107"},"PeriodicalIF":0.0000,"publicationDate":"2000-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(2000)12:2<104::AID-LRA10>3.0.CO;2-4","citationCount":"5","resultStr":"{\"title\":\"Simultaneous multiwavelength detection based on surface plasmon resonance technique\",\"authors\":\"Xiaojun Zhao,&nbsp;Zhen Wang,&nbsp;Ying Mu,&nbsp;Hanqi Zhang,&nbsp;Qinhan Jin\",\"doi\":\"10.1002/(SICI)1098-2728(2000)12:2<104::AID-LRA10>3.0.CO;2-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The present article covers a novel surface plasmon resonance (SPR) instrument based on simultaneous multiwavelength detection. The sensing principle of a traditional SPR device is based on fixing a discrete excitation wavelength and modulating the angle of incident light. The SPR-reflected spectra are shown in terms of reflected light intensity versus angle of incident light. The instrument presented here is designed on the basis of fixing the angle of incident light and measuring the change of resonant wavelength in the wavelength range of 400–800 nm. The SPR spectra are shown in terms of reflected light intensity versus wavelength of the incident light. The intensity of the reflected light is the minimum at the resonant wavelength. With the aid of the device, some chemical sensors and immunosensors, such as the thiolate chemical sensor, the fibrin immunosensor, and the albumin immunosensor were developed. The kinetic processes of formation of various sensing monolayers were studied in real time through observing the change of resonant wavelength. © 2000 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 12:104–107, 2000</p>\",\"PeriodicalId\":100863,\"journal\":{\"name\":\"Laboratory Robotics and Automation\",\"volume\":\"12 2\",\"pages\":\"104-107\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(2000)12:2<104::AID-LRA10>3.0.CO;2-4\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laboratory Robotics and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%282000%2912%3A2%3C104%3A%3AAID-LRA10%3E3.0.CO%3B2-4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%282000%2912%3A2%3C104%3A%3AAID-LRA10%3E3.0.CO%3B2-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文介绍了一种基于多波长同步探测的表面等离子体共振(SPR)仪器。传统SPR器件的传感原理是固定一个离散的激发波长和调制入射光的角度。spr反射光谱用反射光强度与入射光角度的关系表示。本文提出的仪器是在确定入射光的角度,测量400 ~ 800 nm波长范围内谐振波长变化的基础上设计的。SPR光谱用反射光强度与入射光波长的关系表示。反射光的强度在共振波长处最小。在此基础上,研制了硫化物化学传感器、纤维蛋白免疫传感器、白蛋白免疫传感器等化学传感器和免疫传感器。通过观察谐振波长的变化,实时研究了各种传感单层膜形成的动力学过程。©2000 John Wiley &儿子,Inc。实验室机器人与自动化,2000:104 - 107
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simultaneous multiwavelength detection based on surface plasmon resonance technique

The present article covers a novel surface plasmon resonance (SPR) instrument based on simultaneous multiwavelength detection. The sensing principle of a traditional SPR device is based on fixing a discrete excitation wavelength and modulating the angle of incident light. The SPR-reflected spectra are shown in terms of reflected light intensity versus angle of incident light. The instrument presented here is designed on the basis of fixing the angle of incident light and measuring the change of resonant wavelength in the wavelength range of 400–800 nm. The SPR spectra are shown in terms of reflected light intensity versus wavelength of the incident light. The intensity of the reflected light is the minimum at the resonant wavelength. With the aid of the device, some chemical sensors and immunosensors, such as the thiolate chemical sensor, the fibrin immunosensor, and the albumin immunosensor were developed. The kinetic processes of formation of various sensing monolayers were studied in real time through observing the change of resonant wavelength. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:104–107, 2000

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Flow system for calibration and interference examination in two-component analysis Development of hardware and software for on-line sample preparation using sequential-injection analysis Automation of procedures to measure ash content for polyolefin and ryton poly(phenylene sulfide) resins Spectrophotometric determination of phosphite in fertilizers in a flow injection system with online sample preparation Determination of trace amounts of copper using a flow-through spectrophotometric sensor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1