{"title":"NH3, CO2和SO2通过微孔聚四氟乙烯扩散的在线分析","authors":"Irina Tarische, Decebal Ciurchea, Patrizio Madau, Liliana Olenic","doi":"10.1002/(SICI)1098-2728(1999)11:4<224::AID-LRA7>3.0.CO;2-H","DOIUrl":null,"url":null,"abstract":"<p>Dynamic responses of self-made potentiometric NH<sub>3</sub>, CO<sub>2</sub>, and SO<sub>2</sub> sensitive gas sensors are followed in the 10<sup>−5</sup>–5 × 10<sup>−3</sup>M concentration range. By least squares fitting of potential versus time curves, Dk product values at the diffusion of NH<sub>3</sub>, CO<sub>2</sub>, and SO<sub>2</sub> through microporous Teflon are calculated. The obtained results are fairly reflected by the behavior of the sensor. Measurements of potential versus time in mixed solutions of CO<sub>2</sub> and SO<sub>2</sub> with the CO<sub>2</sub> sensitive sensor indicate the presence of the interferent. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 224–228, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 4","pages":"224-228"},"PeriodicalIF":0.0000,"publicationDate":"1999-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:4<224::AID-LRA7>3.0.CO;2-H","citationCount":"1","resultStr":"{\"title\":\"On-line analysis of NH3, CO2, and SO2 diffusion through microporous Teflon\",\"authors\":\"Irina Tarische, Decebal Ciurchea, Patrizio Madau, Liliana Olenic\",\"doi\":\"10.1002/(SICI)1098-2728(1999)11:4<224::AID-LRA7>3.0.CO;2-H\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Dynamic responses of self-made potentiometric NH<sub>3</sub>, CO<sub>2</sub>, and SO<sub>2</sub> sensitive gas sensors are followed in the 10<sup>−5</sup>–5 × 10<sup>−3</sup>M concentration range. By least squares fitting of potential versus time curves, Dk product values at the diffusion of NH<sub>3</sub>, CO<sub>2</sub>, and SO<sub>2</sub> through microporous Teflon are calculated. The obtained results are fairly reflected by the behavior of the sensor. Measurements of potential versus time in mixed solutions of CO<sub>2</sub> and SO<sub>2</sub> with the CO<sub>2</sub> sensitive sensor indicate the presence of the interferent. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 224–228, 1999</p>\",\"PeriodicalId\":100863,\"journal\":{\"name\":\"Laboratory Robotics and Automation\",\"volume\":\"11 4\",\"pages\":\"224-228\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:4<224::AID-LRA7>3.0.CO;2-H\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laboratory Robotics and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%281999%2911%3A4%3C224%3A%3AAID-LRA7%3E3.0.CO%3B2-H\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%281999%2911%3A4%3C224%3A%3AAID-LRA7%3E3.0.CO%3B2-H","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1