I. I. Yusoff, R. Rohani, A. Mohammad
{"title":"Penentuan berat sekatan molekul bagi membran penurasan tekananmelalui kaedah pengesanan kolorimetri","authors":"I. I. Yusoff, R. Rohani, A. Mohammad","doi":"10.17576/MJAS-2017-2102-24","DOIUrl":null,"url":null,"abstract":"Molecular weight cut-off (MWCO) of commercial and in-house fabricated membranes is obtained at 90% rejection of various types of solutes with different molecular weights (MWs). PEG quantification methods have been favorably employed to determine membranes’ MWCO. Most of the quantification methods utilizing high-end equipment using high performance liquid chromatography (HPLC) and low-end colorimetric method. HPLC method requires an established chromatographic technique using specific diluents, columns and detectors while the most referred colorimetric method requires a few processing steps with concentration up to 7.5 ppm by using UV spectrophotometer. In this work, a newly modified colorimetric method was established to conduct a simple measurement for a membrane’s MWCO. The newly modified method has an excellent linearity for the calibration curves which R values are closed to 1 with concentration of up to 150 ppm. A MWCO determination test conducted using different commercial membranes for confirming this newly modified method found that similar MWCO values were obtained as given by the membrane’ manufacturers. In conclusion, this newly modified method is simpler than the formerly used colorimetric method, reliable and applicable for determining the MWCO of membranes ranging from UF to NF at a higher range of PEG concentrations (>150 ppm).","PeriodicalId":22844,"journal":{"name":"The Malaysian Journal of Analytical Sciences","volume":"23 1","pages":"484-495"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Malaysian Journal of Analytical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17576/MJAS-2017-2102-24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

商用和自制膜的分子量截止值(MWCO)在90%的截留率下获得不同分子量(MWs)的各种类型的溶质。聚乙二醇定量法已被广泛应用于测定膜的MWCO。大多数定量方法利用高端设备,采用高效液相色谱(HPLC)和低端比色法。高效液相色谱法需要使用特定的稀释剂、色谱柱和检测器建立色谱技术,而最常用的比色法需要使用紫外分光光度计进行浓度高达7.5 ppm的处理步骤。本文建立了一种改进的比色法,对膜的MWCO进行了简单的测定。新方法对浓度高达150ppm时R值接近1的校准曲线具有良好的线性关系。用不同的商用膜进行了MWCO测定试验,以证实这种新改进的方法,发现获得的MWCO值与膜制造商给出的值相似。综上所述,该方法比以往使用的比色法更简单,可靠,适用于在较高PEG浓度范围(> 150ppm)下测定从UF到NF的膜的MWCO。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Penentuan berat sekatan molekul bagi membran penurasan tekananmelalui kaedah pengesanan kolorimetri
Molecular weight cut-off (MWCO) of commercial and in-house fabricated membranes is obtained at 90% rejection of various types of solutes with different molecular weights (MWs). PEG quantification methods have been favorably employed to determine membranes’ MWCO. Most of the quantification methods utilizing high-end equipment using high performance liquid chromatography (HPLC) and low-end colorimetric method. HPLC method requires an established chromatographic technique using specific diluents, columns and detectors while the most referred colorimetric method requires a few processing steps with concentration up to 7.5 ppm by using UV spectrophotometer. In this work, a newly modified colorimetric method was established to conduct a simple measurement for a membrane’s MWCO. The newly modified method has an excellent linearity for the calibration curves which R values are closed to 1 with concentration of up to 150 ppm. A MWCO determination test conducted using different commercial membranes for confirming this newly modified method found that similar MWCO values were obtained as given by the membrane’ manufacturers. In conclusion, this newly modified method is simpler than the formerly used colorimetric method, reliable and applicable for determining the MWCO of membranes ranging from UF to NF at a higher range of PEG concentrations (>150 ppm).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Validation method for extraction and determination of marbofloxacin in plasma and edible chicken tissues Polymeric films as matrixes for the immobilization of mixed natural dyes for optical ph sensor Analisis kandungan kepekatan logam berat dalam air balast dan air laut di pelabuhan tanjung pelepas Penggunaan pelarut eutektik dalam (DES) sebagai porogen dalam fabrikasi turus kapilari monolitik polimerik Aktinobakteria psikrotoleran Barrientosiimonas humi 39T sebagai sumber sebatian diketopiperazin
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1