用RPLGD法测量小型猪体模辐射剂量分布

Jae Seok Kim, P. Lee, Byeong Ryong Park, Han Sung Kim, Kum-Bae Kim, Gyu-Seok Cho, Sehwan Shim, Wi-Ho Ha, Sunhoo Park, Y. Jin
{"title":"用RPLGD法测量小型猪体模辐射剂量分布","authors":"Jae Seok Kim, P. Lee, Byeong Ryong Park, Han Sung Kim, Kum-Bae Kim, Gyu-Seok Cho, Sehwan Shim, Wi-Ho Ha, Sunhoo Park, Y. Jin","doi":"10.15669/PNST.6.113","DOIUrl":null,"url":null,"abstract":"Radio-photoluminescence glass dosimeter (RPLGD) has many advantages such as small size, high sensitivity, low fading effect, excellent dose linearity and repeatability. Because of these advantages, RPLGDs were used to measure the absorbed dose as in-vivo dosimeter. In Korea Institute of Radiological and Medical Sciences (KIRAMS), a minipig physical phantom was applied to evaluate the dose distribution for animal irradiation study. In this study, RPLGDs were used as a dosimeter to evaluate the dose distribution in the 5th and 25th slices. For the reliable result, RPLGDs were irradiated to evaluate the expanded measurement uncertainty. The expanded measurement uncertainty of RPLGD was determined as 6.08% with a coverage factor of k=2. Additionally, the framework of the Geant4 toolkit was used to verify the dose distribution by using RPLGD measurement under the same experiment condition. To analyze the linearity between the RPLGD measurements and Geant4 simulation, each of absorbed doses was compared according to the measurement points in the minipig physical phantom. As a result, the coefficients of determination (R2) were evaluated as 0.9767 and 0.9852 at each slice of the 5th and 25th.","PeriodicalId":20706,"journal":{"name":"Progress in Nuclear Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of radiation dose distribution in minipig physical phantom using RPLGD\",\"authors\":\"Jae Seok Kim, P. Lee, Byeong Ryong Park, Han Sung Kim, Kum-Bae Kim, Gyu-Seok Cho, Sehwan Shim, Wi-Ho Ha, Sunhoo Park, Y. Jin\",\"doi\":\"10.15669/PNST.6.113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Radio-photoluminescence glass dosimeter (RPLGD) has many advantages such as small size, high sensitivity, low fading effect, excellent dose linearity and repeatability. Because of these advantages, RPLGDs were used to measure the absorbed dose as in-vivo dosimeter. In Korea Institute of Radiological and Medical Sciences (KIRAMS), a minipig physical phantom was applied to evaluate the dose distribution for animal irradiation study. In this study, RPLGDs were used as a dosimeter to evaluate the dose distribution in the 5th and 25th slices. For the reliable result, RPLGDs were irradiated to evaluate the expanded measurement uncertainty. The expanded measurement uncertainty of RPLGD was determined as 6.08% with a coverage factor of k=2. Additionally, the framework of the Geant4 toolkit was used to verify the dose distribution by using RPLGD measurement under the same experiment condition. To analyze the linearity between the RPLGD measurements and Geant4 simulation, each of absorbed doses was compared according to the measurement points in the minipig physical phantom. As a result, the coefficients of determination (R2) were evaluated as 0.9767 and 0.9852 at each slice of the 5th and 25th.\",\"PeriodicalId\":20706,\"journal\":{\"name\":\"Progress in Nuclear Science and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Progress in Nuclear Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15669/PNST.6.113\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Nuclear Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15669/PNST.6.113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

射电-光致发光玻璃剂量计具有体积小、灵敏度高、衰减效应小、剂量线性好、重复性好等优点。由于这些优点,RPLGDs被用作体内剂量计来测量吸收剂量。在韩国放射医学研究所(KIRAMS),采用迷你猪物理模型评估动物辐照剂量分布。本研究采用RPLGDs作为剂量计,评估第5片和第25片的剂量分布。为了获得可靠的测量结果,对RPLGDs进行了辐照,以评估扩展的测量不确定度。确定RPLGD的扩展测量不确定度为6.08%,覆盖系数为k=2。另外,利用Geant4工具箱框架,在相同实验条件下,通过RPLGD测量验证剂量分布。为了分析RPLGD测量值与Geant4模拟之间的线性关系,根据迷你猪物理模型中的测量点对每个吸收剂量进行比较。结果,第5、25切片的决定系数(R2)分别为0.9767、0.9852。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurement of radiation dose distribution in minipig physical phantom using RPLGD
Radio-photoluminescence glass dosimeter (RPLGD) has many advantages such as small size, high sensitivity, low fading effect, excellent dose linearity and repeatability. Because of these advantages, RPLGDs were used to measure the absorbed dose as in-vivo dosimeter. In Korea Institute of Radiological and Medical Sciences (KIRAMS), a minipig physical phantom was applied to evaluate the dose distribution for animal irradiation study. In this study, RPLGDs were used as a dosimeter to evaluate the dose distribution in the 5th and 25th slices. For the reliable result, RPLGDs were irradiated to evaluate the expanded measurement uncertainty. The expanded measurement uncertainty of RPLGD was determined as 6.08% with a coverage factor of k=2. Additionally, the framework of the Geant4 toolkit was used to verify the dose distribution by using RPLGD measurement under the same experiment condition. To analyze the linearity between the RPLGD measurements and Geant4 simulation, each of absorbed doses was compared according to the measurement points in the minipig physical phantom. As a result, the coefficients of determination (R2) were evaluated as 0.9767 and 0.9852 at each slice of the 5th and 25th.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Estimation of the characteristics of gamma-ray dose measurements with an experimental wireless dose monitoring system Proposal of framework for decision making of additional monitoring of eye lens dose for radiation workers Development of wide one-dimensional X-ray line sensor in backscatter X-ray imaging system for infrastructure inspection Evaluation of imaging plate measurement for activated indium as fast-neutron detector in large radiation field Development of a simultaneous evaluation method of radioactivity in soil and dose rate using CeBr3 and SrI2(Eu) scintillation detectors for environmental monitoring
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1