Raluca-Ioana Stefan , Jacobus F van Staden , Hassan Y Aboul-Enein
{"title":"用含氟选择膜电极的流动注射系统测定牙膏、废水、天然水和钻孔水中的氟化物","authors":"Raluca-Ioana Stefan , Jacobus F van Staden , Hassan Y Aboul-Enein","doi":"10.1016/S0031-6865(99)00008-4","DOIUrl":null,"url":null,"abstract":"<div><p><span>An automated system for the determination of fluoride in toothpaste, effluent streams, natural and borehole water based on the concept of flow injection with a fluoride-selective membrane electrode as sensor is described. The system is suitable for the on-line monitoring of fluoride at a sampling rate of 60 samples h</span><sup>−1</sup> in the linear range 10<sup>−4</sup>–10<sup>−1</sup> (approximately 1.9–1900 mg l<sup>−1</sup>) with an RSD of better than 0.6%.</p></div>","PeriodicalId":19830,"journal":{"name":"Pharmaceutica acta Helvetiae","volume":"73 6","pages":"Pages 307-310"},"PeriodicalIF":0.0000,"publicationDate":"1999-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0031-6865(99)00008-4","citationCount":"16","resultStr":"{\"title\":\"Determination of fluoride in toothpaste, effluent streams and natural and borehole water using a flow injection system with a fluoride-selective membrane electrode\",\"authors\":\"Raluca-Ioana Stefan , Jacobus F van Staden , Hassan Y Aboul-Enein\",\"doi\":\"10.1016/S0031-6865(99)00008-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p><span>An automated system for the determination of fluoride in toothpaste, effluent streams, natural and borehole water based on the concept of flow injection with a fluoride-selective membrane electrode as sensor is described. The system is suitable for the on-line monitoring of fluoride at a sampling rate of 60 samples h</span><sup>−1</sup> in the linear range 10<sup>−4</sup>–10<sup>−1</sup> (approximately 1.9–1900 mg l<sup>−1</sup>) with an RSD of better than 0.6%.</p></div>\",\"PeriodicalId\":19830,\"journal\":{\"name\":\"Pharmaceutica acta Helvetiae\",\"volume\":\"73 6\",\"pages\":\"Pages 307-310\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0031-6865(99)00008-4\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmaceutica acta Helvetiae\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0031686599000084\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutica acta Helvetiae","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0031686599000084","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Determination of fluoride in toothpaste, effluent streams and natural and borehole water using a flow injection system with a fluoride-selective membrane electrode
An automated system for the determination of fluoride in toothpaste, effluent streams, natural and borehole water based on the concept of flow injection with a fluoride-selective membrane electrode as sensor is described. The system is suitable for the on-line monitoring of fluoride at a sampling rate of 60 samples h−1 in the linear range 10−4–10−1 (approximately 1.9–1900 mg l−1) with an RSD of better than 0.6%.