{"title":"增强发射率的热成像分析","authors":"D. Varsescu, V. Ilian, M. Bazu","doi":"10.1109/SMICND.2014.6966462","DOIUrl":null,"url":null,"abstract":"A FLIR SC5000 IR thermovision camera was used for analyzing the temperature distribution on the gold surface of the test devices (Schottky diode). The goal was to estimate the values of the temperature in various areas on the surface of the test device. In order to increase the emissivity, the surface was covered with a spray paint, a solution allowing to obtaining better estimations of the surface temperature.","PeriodicalId":6616,"journal":{"name":"2014 International Semiconductor Conference (CAS)","volume":"13 1","pages":"283-286"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Thermographic analysis with enhanced emissivity\",\"authors\":\"D. Varsescu, V. Ilian, M. Bazu\",\"doi\":\"10.1109/SMICND.2014.6966462\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A FLIR SC5000 IR thermovision camera was used for analyzing the temperature distribution on the gold surface of the test devices (Schottky diode). The goal was to estimate the values of the temperature in various areas on the surface of the test device. In order to increase the emissivity, the surface was covered with a spray paint, a solution allowing to obtaining better estimations of the surface temperature.\",\"PeriodicalId\":6616,\"journal\":{\"name\":\"2014 International Semiconductor Conference (CAS)\",\"volume\":\"13 1\",\"pages\":\"283-286\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Semiconductor Conference (CAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SMICND.2014.6966462\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Semiconductor Conference (CAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SMICND.2014.6966462","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A FLIR SC5000 IR thermovision camera was used for analyzing the temperature distribution on the gold surface of the test devices (Schottky diode). The goal was to estimate the values of the temperature in various areas on the surface of the test device. In order to increase the emissivity, the surface was covered with a spray paint, a solution allowing to obtaining better estimations of the surface temperature.