{"title":"工业燃气轮机性能预测与改进——一个案例研究","authors":"H. Mzad, Fethi Bennour","doi":"10.1515/ehs-2022-0094","DOIUrl":null,"url":null,"abstract":"Abstract The gas turbines (GTs), model M3142R/GE MS 3002, equipping the natural gas compression and crude oil pumping stations of SONATRACH’s pipeline transport of hydrocarbons activity are robust despite their dilapidation and state of service, but mediocre in terms of energy efficiency and power output. According to the manufacturer, for temperatures ranging from 15 to 47 °C, the efficiency of these machines drops from 26.78 to 25.03 % and their power drops from 11.29 to 8.9191 MW. It should be noted, however, that the number of these turbines exceeds 80 units and that their operation dates from 1974. The intention of this paper is to improve the gas turbine performance, mainly the efficiency and shaft power, by an evaporative cooling process of the compressor intake air. Besides, it is proposed to lower the upper limit power in periods of high temperatures to reduce gas consumption. To achieve these objectives, a mathematical model was implemented under Matlab R16, which reproduced the real behavior of these machines. It follows that this simulation made it possible to highlight relevant gains in terms of power and efficiency of the order of 1.361 MW and 3.4 % at a temperature of 47 °C.","PeriodicalId":36885,"journal":{"name":"Energy Harvesting and Systems","volume":"12 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Industrial gas turbine performance prediction and improvement – a case study\",\"authors\":\"H. Mzad, Fethi Bennour\",\"doi\":\"10.1515/ehs-2022-0094\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The gas turbines (GTs), model M3142R/GE MS 3002, equipping the natural gas compression and crude oil pumping stations of SONATRACH’s pipeline transport of hydrocarbons activity are robust despite their dilapidation and state of service, but mediocre in terms of energy efficiency and power output. According to the manufacturer, for temperatures ranging from 15 to 47 °C, the efficiency of these machines drops from 26.78 to 25.03 % and their power drops from 11.29 to 8.9191 MW. It should be noted, however, that the number of these turbines exceeds 80 units and that their operation dates from 1974. The intention of this paper is to improve the gas turbine performance, mainly the efficiency and shaft power, by an evaporative cooling process of the compressor intake air. Besides, it is proposed to lower the upper limit power in periods of high temperatures to reduce gas consumption. To achieve these objectives, a mathematical model was implemented under Matlab R16, which reproduced the real behavior of these machines. It follows that this simulation made it possible to highlight relevant gains in terms of power and efficiency of the order of 1.361 MW and 3.4 % at a temperature of 47 °C.\",\"PeriodicalId\":36885,\"journal\":{\"name\":\"Energy Harvesting and Systems\",\"volume\":\"12 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Harvesting and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/ehs-2022-0094\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Harvesting and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/ehs-2022-0094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
摘要
SONATRACH公司烃类管道输送天然气压缩站和原油泵站所装备的M3142R/GE MS 3002型燃气轮机(GTs)虽然破旧且处于使用状态,但性能稳定,但能效和输出功率一般。根据制造商的说法,在15到47 °C的温度范围内,这些机器的效率从26.78下降到25.03 %,功率从11.29下降到8.9191 MW。但是,应当指出,这些涡轮机的数量超过80台,它们的运行时间从1974年开始。本文的目的是通过压缩机进气的蒸发冷却过程来提高燃气轮机的性能,主要是效率和轴功率。此外,还建议在高温时降低上限功率,以减少燃气消耗。为了实现这些目标,在Matlab R16下实现了一个数学模型,该模型再现了这些机器的真实行为。由此可见,在47 °C的温度下,该模拟可以突出显示功率和效率方面的相关增益,分别为1.361 MW和3.4 %。
Industrial gas turbine performance prediction and improvement – a case study
Abstract The gas turbines (GTs), model M3142R/GE MS 3002, equipping the natural gas compression and crude oil pumping stations of SONATRACH’s pipeline transport of hydrocarbons activity are robust despite their dilapidation and state of service, but mediocre in terms of energy efficiency and power output. According to the manufacturer, for temperatures ranging from 15 to 47 °C, the efficiency of these machines drops from 26.78 to 25.03 % and their power drops from 11.29 to 8.9191 MW. It should be noted, however, that the number of these turbines exceeds 80 units and that their operation dates from 1974. The intention of this paper is to improve the gas turbine performance, mainly the efficiency and shaft power, by an evaporative cooling process of the compressor intake air. Besides, it is proposed to lower the upper limit power in periods of high temperatures to reduce gas consumption. To achieve these objectives, a mathematical model was implemented under Matlab R16, which reproduced the real behavior of these machines. It follows that this simulation made it possible to highlight relevant gains in terms of power and efficiency of the order of 1.361 MW and 3.4 % at a temperature of 47 °C.