{"title":"散射介质中空间定域弹道双光子激发†","authors":"Henryk Szmacinski, Ignacy Gryczynski, Joseph R. Lakowicz","doi":"10.1002/(SICI)1520-6343(1998)4:5<303::AID-BSPY2>3.0.CO;2-X","DOIUrl":null,"url":null,"abstract":"<p>We describe spatially localized two-photon excitation in scattering media. Using femtosecond pulses at 770 nm from a Ti : Sapphire laser, we were able to excite fluorophores in capillary tubes under up to 1.5 mm of 0.5% intralipid. Displacement of the laser beam relative to the embedded samples indicates that highly localized excitation was possible with two-photon excitation, whereas one-photon excitation resulted in loss of spatial resolution due to excitation by the diffusely scattered photons. These results indicate that two-photon excitation in the scattering solution is due only to the ballistic photons, a result confirmed by frequency-domain time-resolved measurements. Selective excitation of adjacent embedded samples was found possible for two but not one-photon excitation. © 1998 John Wiley & Sons, Inc. Biospectroscopy 4: 303–310, 1998</p>","PeriodicalId":9037,"journal":{"name":"Biospectroscopy","volume":"4 5","pages":"303-310"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1520-6343(1998)4:5<303::AID-BSPY2>3.0.CO;2-X","citationCount":"27","resultStr":"{\"title\":\"Spatially localized ballistic two-photon excitation in scattering media†\",\"authors\":\"Henryk Szmacinski, Ignacy Gryczynski, Joseph R. Lakowicz\",\"doi\":\"10.1002/(SICI)1520-6343(1998)4:5<303::AID-BSPY2>3.0.CO;2-X\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>We describe spatially localized two-photon excitation in scattering media. Using femtosecond pulses at 770 nm from a Ti : Sapphire laser, we were able to excite fluorophores in capillary tubes under up to 1.5 mm of 0.5% intralipid. Displacement of the laser beam relative to the embedded samples indicates that highly localized excitation was possible with two-photon excitation, whereas one-photon excitation resulted in loss of spatial resolution due to excitation by the diffusely scattered photons. These results indicate that two-photon excitation in the scattering solution is due only to the ballistic photons, a result confirmed by frequency-domain time-resolved measurements. Selective excitation of adjacent embedded samples was found possible for two but not one-photon excitation. © 1998 John Wiley & Sons, Inc. Biospectroscopy 4: 303–310, 1998</p>\",\"PeriodicalId\":9037,\"journal\":{\"name\":\"Biospectroscopy\",\"volume\":\"4 5\",\"pages\":\"303-310\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-01-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/(SICI)1520-6343(1998)4:5<303::AID-BSPY2>3.0.CO;2-X\",\"citationCount\":\"27\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biospectroscopy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291520-6343%281998%294%3A5%3C303%3A%3AAID-BSPY2%3E3.0.CO%3B2-X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biospectroscopy","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291520-6343%281998%294%3A5%3C303%3A%3AAID-BSPY2%3E3.0.CO%3B2-X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 27