Paulo Roberto Rodrigues Martini, Douglas Dos Santos Porto, Paola Ribeiro Motta, Lisiane Bajerski, Marcelo Donadel Malesuik, Clésio Soldateli Paim
{"title":"反相高效液相色谱法(RP-HPLC):环境友好的稳定性指示方法","authors":"Paulo Roberto Rodrigues Martini, Douglas Dos Santos Porto, Paola Ribeiro Motta, Lisiane Bajerski, Marcelo Donadel Malesuik, Clésio Soldateli Paim","doi":"10.22456/2527-2616.120940","DOIUrl":null,"url":null,"abstract":"This study describes the development and validation of a new environmentally friendly analytical method for the determination of bilastine in coated tablets and the evaluation of its capacity to be stability-indicating as well. The ecofriendly analytical method was validated by specificity, linearity, accuracy, precision and robustness by reversed-phase high-performance liquid chromatography (RP-HPLC) according to International Conference on Harmonization guidelines (ICH) and Association of Official Analytical Chemists (AOAC). Isocratic LC separation was achieved on a RP18 column using a mobile phase of sodium dihydrogen phosphate aqueous buffer solution adjusted to pH (6.0 ± 0.1) with o-phosphoric acid (85% v/v) and triethylamine (0,3% v/v) and ethanol (EtOH) in the following proportions (60:40 v/v), at a flow rate of 1.0 mL·min-1 at temperature-controlled at 30 °C. The analytical method showed selectivity, good recovery and precision (intra- and inter-day), robustness, and linear over a range from 5.0 to 50 μg·mL-1.","PeriodicalId":11314,"journal":{"name":"Drug Analytical Research","volume":"9 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Bilastine: stability-indicating a method using environmentally friendly by reversed-phase high-performance liquid chromatography (RP-HPLC)\",\"authors\":\"Paulo Roberto Rodrigues Martini, Douglas Dos Santos Porto, Paola Ribeiro Motta, Lisiane Bajerski, Marcelo Donadel Malesuik, Clésio Soldateli Paim\",\"doi\":\"10.22456/2527-2616.120940\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study describes the development and validation of a new environmentally friendly analytical method for the determination of bilastine in coated tablets and the evaluation of its capacity to be stability-indicating as well. The ecofriendly analytical method was validated by specificity, linearity, accuracy, precision and robustness by reversed-phase high-performance liquid chromatography (RP-HPLC) according to International Conference on Harmonization guidelines (ICH) and Association of Official Analytical Chemists (AOAC). Isocratic LC separation was achieved on a RP18 column using a mobile phase of sodium dihydrogen phosphate aqueous buffer solution adjusted to pH (6.0 ± 0.1) with o-phosphoric acid (85% v/v) and triethylamine (0,3% v/v) and ethanol (EtOH) in the following proportions (60:40 v/v), at a flow rate of 1.0 mL·min-1 at temperature-controlled at 30 °C. The analytical method showed selectivity, good recovery and precision (intra- and inter-day), robustness, and linear over a range from 5.0 to 50 μg·mL-1.\",\"PeriodicalId\":11314,\"journal\":{\"name\":\"Drug Analytical Research\",\"volume\":\"9 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Drug Analytical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22456/2527-2616.120940\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Analytical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22456/2527-2616.120940","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Bilastine: stability-indicating a method using environmentally friendly by reversed-phase high-performance liquid chromatography (RP-HPLC)
This study describes the development and validation of a new environmentally friendly analytical method for the determination of bilastine in coated tablets and the evaluation of its capacity to be stability-indicating as well. The ecofriendly analytical method was validated by specificity, linearity, accuracy, precision and robustness by reversed-phase high-performance liquid chromatography (RP-HPLC) according to International Conference on Harmonization guidelines (ICH) and Association of Official Analytical Chemists (AOAC). Isocratic LC separation was achieved on a RP18 column using a mobile phase of sodium dihydrogen phosphate aqueous buffer solution adjusted to pH (6.0 ± 0.1) with o-phosphoric acid (85% v/v) and triethylamine (0,3% v/v) and ethanol (EtOH) in the following proportions (60:40 v/v), at a flow rate of 1.0 mL·min-1 at temperature-controlled at 30 °C. The analytical method showed selectivity, good recovery and precision (intra- and inter-day), robustness, and linear over a range from 5.0 to 50 μg·mL-1.