{"title":"正畸托槽的腐蚀:定性和定量表面分析。","authors":"Romy A Doomen, Ivana Nedeljkovic, Reinder B Kuitert, Cornelis J Kleverlaan, Burcu Aydin","doi":"10.2319/072321-584.1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To determine and compare surface characteristics and presence of corrosion in new and used brackets with optical light microscopy (OLM) and scanning electron microscopy (SEM), and with elemental chemical analysis with energy-dispersive X-ray spectroscopy (EDS).</p><p><strong>Materials and methods: </strong>OLM and SEM were used to analyze 24 new and 24 used conventional premolar brackets. EDS analysis was performed in six used brackets and four new brackets with corrosion-suspected spots.</p><p><strong>Results: </strong>OLM and SEM images showed wear/abfraction signs, striations, pits/crevices, and adherent material. Used brackets showed more deterioration than new brackets. SEM images disclosed more morphological features than OLM images. EDS analysis revealed a significantly higher phosphorus (P = .001) and sodium (P < .005) weight fraction and significantly lower amounts of chromium (P < .001) in used brackets. The iron, chromium, and nickel weight fractions did not differ significantly between the clean and corrosion-suspected spots. Of the corrosion-suspected spots analyzed by combined SEM and EDS, 44.14% and 6.90% remained corrosion-suspected on used and new brackets, respectively.</p><p><strong>Conclusions: </strong>Used brackets showed more signs of corrosion than new ones. Combined assessment of SEM and EDS indicates that the bracket surface is affected during orthodontic treatment as a result of corrosion.</p>","PeriodicalId":94224,"journal":{"name":"The Angle orthodontist","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9374347/pdf/","citationCount":"0","resultStr":"{\"title\":\"Corrosion of orthodontic brackets: qualitative and quantitative surface analysis.\",\"authors\":\"Romy A Doomen, Ivana Nedeljkovic, Reinder B Kuitert, Cornelis J Kleverlaan, Burcu Aydin\",\"doi\":\"10.2319/072321-584.1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To determine and compare surface characteristics and presence of corrosion in new and used brackets with optical light microscopy (OLM) and scanning electron microscopy (SEM), and with elemental chemical analysis with energy-dispersive X-ray spectroscopy (EDS).</p><p><strong>Materials and methods: </strong>OLM and SEM were used to analyze 24 new and 24 used conventional premolar brackets. EDS analysis was performed in six used brackets and four new brackets with corrosion-suspected spots.</p><p><strong>Results: </strong>OLM and SEM images showed wear/abfraction signs, striations, pits/crevices, and adherent material. Used brackets showed more deterioration than new brackets. SEM images disclosed more morphological features than OLM images. EDS analysis revealed a significantly higher phosphorus (P = .001) and sodium (P < .005) weight fraction and significantly lower amounts of chromium (P < .001) in used brackets. The iron, chromium, and nickel weight fractions did not differ significantly between the clean and corrosion-suspected spots. Of the corrosion-suspected spots analyzed by combined SEM and EDS, 44.14% and 6.90% remained corrosion-suspected on used and new brackets, respectively.</p><p><strong>Conclusions: </strong>Used brackets showed more signs of corrosion than new ones. Combined assessment of SEM and EDS indicates that the bracket surface is affected during orthodontic treatment as a result of corrosion.</p>\",\"PeriodicalId\":94224,\"journal\":{\"name\":\"The Angle orthodontist\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9374347/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Angle orthodontist\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2319/072321-584.1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Angle orthodontist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2319/072321-584.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目标:利用光学显微镜(OLM)和扫描电子显微镜(SEM)以及能量色散 X 射线光谱(EDS)进行元素化学分析,确定并比较新旧托槽的表面特征和是否存在腐蚀:使用光学显微镜和扫描电子显微镜分析了 24 个新的和 24 个使用过的传统前磨牙托架。对 6 个使用过的托槽和 4 个有腐蚀斑点的新托槽进行了 EDS 分析:结果:OLM 和 SEM 图像显示了磨损/折损迹象、条纹、凹坑/缝隙和附着材料。与新支架相比,旧支架的老化程度更严重。与 OLM 图像相比,SEM 图像显示了更多的形态特征。EDS 分析显示,旧托槽中磷的重量分数(P = .001)和钠的重量分数(P < .005)明显较高,而铬的含量(P < .001)则明显较低。铁、铬和镍的重量分数在清洁点和疑似腐蚀点之间没有明显差异。在 SEM 和 EDS 联合分析的疑似腐蚀点中,旧支架和新支架的疑似腐蚀点分别占 44.14% 和 6.90%:结论:旧托架比新托架显示出更多的腐蚀迹象。SEM 和 EDS 的综合评估表明,托槽表面在正畸治疗过程中会受到腐蚀的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Corrosion of orthodontic brackets: qualitative and quantitative surface analysis.

Objectives: To determine and compare surface characteristics and presence of corrosion in new and used brackets with optical light microscopy (OLM) and scanning electron microscopy (SEM), and with elemental chemical analysis with energy-dispersive X-ray spectroscopy (EDS).

Materials and methods: OLM and SEM were used to analyze 24 new and 24 used conventional premolar brackets. EDS analysis was performed in six used brackets and four new brackets with corrosion-suspected spots.

Results: OLM and SEM images showed wear/abfraction signs, striations, pits/crevices, and adherent material. Used brackets showed more deterioration than new brackets. SEM images disclosed more morphological features than OLM images. EDS analysis revealed a significantly higher phosphorus (P = .001) and sodium (P < .005) weight fraction and significantly lower amounts of chromium (P < .001) in used brackets. The iron, chromium, and nickel weight fractions did not differ significantly between the clean and corrosion-suspected spots. Of the corrosion-suspected spots analyzed by combined SEM and EDS, 44.14% and 6.90% remained corrosion-suspected on used and new brackets, respectively.

Conclusions: Used brackets showed more signs of corrosion than new ones. Combined assessment of SEM and EDS indicates that the bracket surface is affected during orthodontic treatment as a result of corrosion.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Three-dimensional assessment of the nasopharyngeal airway in Down syndrome during the mixed dentition period: a case-control study. Strategic treatment for a patient with missing lateral incisor and first molar accompanied by posterior scissor bite and an impacted premolar. Evaluation of dentoalveolar changes following maxillary incisor intrusion with one vs two anterior miniscrews in subjects with gummy smile: a randomized clinical trial. The OHStat guidelines for reporting observational studies and clinical trials in oral health research: manuscript checklist. A skeletal Class III young adult with severe maxillary transverse deficiency treated with maxillary skeletal expander.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1