{"title":"非特征谐波不健康电力系统的辨识","authors":"X. Liang, Y. Luy","doi":"10.5923/J.IJEE.20110101.03","DOIUrl":null,"url":null,"abstract":"Non-characteristics harmonics including even and 3 rd harmonics commonly exist in the electrical power sys- tems but in small amount which are usually below IEEE Std 519-1992 limits. However, in some cases significant amount of non-characteristic harmonics might be present in an industrial facility, which could be an indication of unhealthy power systems. Two case studies are performed in this paper. Case study 1 is about an even harmonic issue in a large mining sys- tem, where large 3 rd harmonic currents are also present. Case study 2 is a triplen harmonic issue at the input of multiple variable frequency drives experienced in an oil field distribution system. The root cause for even harmonics in Case 1 is the malfunction of two large rectifiers in the mining facility, while the root cause for 3 rd harmonics in both cases is the vol- tage unbalance issue from the utility side. The two case studies verify that non-characteristic harmonics can serve as an indication for unhealthy power systems. When they are detected in unusually large amounts, an analysis and troubleshoot- ing is always recommended in order to have a stable and reliable operation of electrical power systems.","PeriodicalId":14041,"journal":{"name":"International journal of energy engineering","volume":"1 1","pages":"12-18"},"PeriodicalIF":0.0000,"publicationDate":"2012-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Identification of Unhealthy Power Systems with Non-Charateristic Harmonics\",\"authors\":\"X. Liang, Y. Luy\",\"doi\":\"10.5923/J.IJEE.20110101.03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Non-characteristics harmonics including even and 3 rd harmonics commonly exist in the electrical power sys- tems but in small amount which are usually below IEEE Std 519-1992 limits. However, in some cases significant amount of non-characteristic harmonics might be present in an industrial facility, which could be an indication of unhealthy power systems. Two case studies are performed in this paper. Case study 1 is about an even harmonic issue in a large mining sys- tem, where large 3 rd harmonic currents are also present. Case study 2 is a triplen harmonic issue at the input of multiple variable frequency drives experienced in an oil field distribution system. The root cause for even harmonics in Case 1 is the malfunction of two large rectifiers in the mining facility, while the root cause for 3 rd harmonics in both cases is the vol- tage unbalance issue from the utility side. The two case studies verify that non-characteristic harmonics can serve as an indication for unhealthy power systems. When they are detected in unusually large amounts, an analysis and troubleshoot- ing is always recommended in order to have a stable and reliable operation of electrical power systems.\",\"PeriodicalId\":14041,\"journal\":{\"name\":\"International journal of energy engineering\",\"volume\":\"1 1\",\"pages\":\"12-18\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of energy engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5923/J.IJEE.20110101.03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of energy engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5923/J.IJEE.20110101.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Identification of Unhealthy Power Systems with Non-Charateristic Harmonics
Non-characteristics harmonics including even and 3 rd harmonics commonly exist in the electrical power sys- tems but in small amount which are usually below IEEE Std 519-1992 limits. However, in some cases significant amount of non-characteristic harmonics might be present in an industrial facility, which could be an indication of unhealthy power systems. Two case studies are performed in this paper. Case study 1 is about an even harmonic issue in a large mining sys- tem, where large 3 rd harmonic currents are also present. Case study 2 is a triplen harmonic issue at the input of multiple variable frequency drives experienced in an oil field distribution system. The root cause for even harmonics in Case 1 is the malfunction of two large rectifiers in the mining facility, while the root cause for 3 rd harmonics in both cases is the vol- tage unbalance issue from the utility side. The two case studies verify that non-characteristic harmonics can serve as an indication for unhealthy power systems. When they are detected in unusually large amounts, an analysis and troubleshoot- ing is always recommended in order to have a stable and reliable operation of electrical power systems.