K. Haji, D. Shiibara, Y. Arata, T. Sakoda, M. Otsubo
{"title":"用动态跌落试验评价局部电弧放电和硅橡胶表面特性","authors":"K. Haji, D. Shiibara, Y. Arata, T. Sakoda, M. Otsubo","doi":"10.1109/CEIDP.2008.4772897","DOIUrl":null,"url":null,"abstract":"This paper describes the results of experiments made to examine characteristics of hydrophobicity of ATH-filled silicone rubber specimen surface. As the examination method, we used a dynamic drop test (DDT), in which electrolyte solution droplet from an electrode continuously dropped on a sample and the AC voltage was supplied between electrodes. Hydrophobicity loss times of samples for various conductivities of electrolyte solutions were measured. The electric fields before and after hydrophobicity reduction were evaluated. The results showed that the hydrophobicity loss time became short with the increase of conductivity and the electric field increased after hydrophobicity reduction.","PeriodicalId":6381,"journal":{"name":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"19 1","pages":"272-275"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Characteristics evaluation of the Partial Arc Discharge and the Silicone Rubber surface by Dynamic Drop Test\",\"authors\":\"K. Haji, D. Shiibara, Y. Arata, T. Sakoda, M. Otsubo\",\"doi\":\"10.1109/CEIDP.2008.4772897\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the results of experiments made to examine characteristics of hydrophobicity of ATH-filled silicone rubber specimen surface. As the examination method, we used a dynamic drop test (DDT), in which electrolyte solution droplet from an electrode continuously dropped on a sample and the AC voltage was supplied between electrodes. Hydrophobicity loss times of samples for various conductivities of electrolyte solutions were measured. The electric fields before and after hydrophobicity reduction were evaluated. The results showed that the hydrophobicity loss time became short with the increase of conductivity and the electric field increased after hydrophobicity reduction.\",\"PeriodicalId\":6381,\"journal\":{\"name\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"19 1\",\"pages\":\"272-275\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2008.4772897\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2008.4772897","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
摘要
本文介绍了对ath填充硅橡胶试样表面疏水性特性进行研究的实验结果。我们采用了动态滴落试验(dynamic drop test, DDT)作为检测方法,即电极上的电解质溶液滴在样品上连续滴下,并在电极之间提供交流电压。测定了不同电导率的电解质溶液样品的疏水性损失次数。对疏水还原前后的电场进行了评价。结果表明,随着电导率的增加,疏水性损失时间变短,疏水性降低后电场增大。
Characteristics evaluation of the Partial Arc Discharge and the Silicone Rubber surface by Dynamic Drop Test
This paper describes the results of experiments made to examine characteristics of hydrophobicity of ATH-filled silicone rubber specimen surface. As the examination method, we used a dynamic drop test (DDT), in which electrolyte solution droplet from an electrode continuously dropped on a sample and the AC voltage was supplied between electrodes. Hydrophobicity loss times of samples for various conductivities of electrolyte solutions were measured. The electric fields before and after hydrophobicity reduction were evaluated. The results showed that the hydrophobicity loss time became short with the increase of conductivity and the electric field increased after hydrophobicity reduction.