一种利用超声传感器进行平衡评估的改进数字式功能到达测试装置:效度和信度测试

IF 0.8 Q4 HEALTH CARE SCIENCES & SERVICES Biomedical Human Kinetics Pub Date : 2021-10-05 DOI:10.2478/bhk-2022-0001
Panida Hanphitakphong, Somruthai Poomsalood, C. Chamroon, Palagon Udomkichpagon
{"title":"一种利用超声传感器进行平衡评估的改进数字式功能到达测试装置:效度和信度测试","authors":"Panida Hanphitakphong, Somruthai Poomsalood, C. Chamroon, Palagon Udomkichpagon","doi":"10.2478/bhk-2022-0001","DOIUrl":null,"url":null,"abstract":"Abstract Study aim: Evaluation of dynamic balance is inferred to be compulsory for fall prevention in the elderly. Therefore, this study aimed to develop a modified digital functional reach test device using an ultrasonic sensor for balance assessment and to test validity and reliability of the newly developed tool to qualify psychometric properties. Material and methods: This study was a cross-sectional study of a convenient sample including 50 participants both males and females. Mean age of the participants was 51.20 ± 19.30 years. Reliability of the newly developed device was analysed using the intraclass correlation coefficient (ICC) and standard error of measurement (SEM). The criterion validity was also investigated using a yardstick mounted on the wall at a level of shoulder together with the MaxTraq® 2D motion analysis software. The modified digital functional reach test device using an ultrasonic sensor was correlated with the conventional FRT and the MaxTraq® 2D motion analysis. Results: The results presented that test-retest reliability of the modified digital functional reach test device was good reliability (ICC = 0.76) and low standard error of measurement (1.41) was found for test-retest reliability. The degree of agreement between the modified device, the conventional FRT, and the MaxTraq® 2D motion analysis was high (r = 0.71 and 0.77 respectively). Conclusions: The findings suggested that the modified digital functional reach test device using an ultrasonic sensor was a valid and reliable instrument for fall risk screening towards functional reach distance.","PeriodicalId":44223,"journal":{"name":"Biomedical Human Kinetics","volume":"2 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2021-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A modified digital functional reach test device using an ultrasonic sensor for balance assessment: A test of validity and reliability\",\"authors\":\"Panida Hanphitakphong, Somruthai Poomsalood, C. Chamroon, Palagon Udomkichpagon\",\"doi\":\"10.2478/bhk-2022-0001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Study aim: Evaluation of dynamic balance is inferred to be compulsory for fall prevention in the elderly. Therefore, this study aimed to develop a modified digital functional reach test device using an ultrasonic sensor for balance assessment and to test validity and reliability of the newly developed tool to qualify psychometric properties. Material and methods: This study was a cross-sectional study of a convenient sample including 50 participants both males and females. Mean age of the participants was 51.20 ± 19.30 years. Reliability of the newly developed device was analysed using the intraclass correlation coefficient (ICC) and standard error of measurement (SEM). The criterion validity was also investigated using a yardstick mounted on the wall at a level of shoulder together with the MaxTraq® 2D motion analysis software. The modified digital functional reach test device using an ultrasonic sensor was correlated with the conventional FRT and the MaxTraq® 2D motion analysis. Results: The results presented that test-retest reliability of the modified digital functional reach test device was good reliability (ICC = 0.76) and low standard error of measurement (1.41) was found for test-retest reliability. The degree of agreement between the modified device, the conventional FRT, and the MaxTraq® 2D motion analysis was high (r = 0.71 and 0.77 respectively). Conclusions: The findings suggested that the modified digital functional reach test device using an ultrasonic sensor was a valid and reliable instrument for fall risk screening towards functional reach distance.\",\"PeriodicalId\":44223,\"journal\":{\"name\":\"Biomedical Human Kinetics\",\"volume\":\"2 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Human Kinetics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/bhk-2022-0001\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Human Kinetics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/bhk-2022-0001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 1

摘要

摘要研究目的:推测动态平衡评估是老年人预防跌倒的必要条件。因此,本研究旨在利用超声传感器开发一种改进的数字功能到达测试装置,用于平衡评估,并测试新开发的工具的有效性和可靠性,以评估心理测量特性。材料和方法:本研究为横断面研究,选取方便的样本,包括50名男女参与者。参与者平均年龄51.20±19.30岁。采用类内相关系数(ICC)和测量标准误差(SEM)对该装置的可靠性进行了分析。还使用安装在肩部水平墙上的标尺以及MaxTraq®2D运动分析软件来调查标准的有效性。使用超声波传感器的改进数字功能到达测试装置与传统的FRT和MaxTraq®2D运动分析相关联。结果:改进后的数字式功能到达测试装置的重测信度较好(ICC = 0.76),重测信度的测量标准误差较低(1.41)。改良装置、传统FRT和MaxTraq®2D运动分析之间的一致性很高(r分别为0.71和0.77)。结论:改进的超声传感器数字式功能够远测试装置是一种有效、可靠的功能够远风险筛查仪器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A modified digital functional reach test device using an ultrasonic sensor for balance assessment: A test of validity and reliability
Abstract Study aim: Evaluation of dynamic balance is inferred to be compulsory for fall prevention in the elderly. Therefore, this study aimed to develop a modified digital functional reach test device using an ultrasonic sensor for balance assessment and to test validity and reliability of the newly developed tool to qualify psychometric properties. Material and methods: This study was a cross-sectional study of a convenient sample including 50 participants both males and females. Mean age of the participants was 51.20 ± 19.30 years. Reliability of the newly developed device was analysed using the intraclass correlation coefficient (ICC) and standard error of measurement (SEM). The criterion validity was also investigated using a yardstick mounted on the wall at a level of shoulder together with the MaxTraq® 2D motion analysis software. The modified digital functional reach test device using an ultrasonic sensor was correlated with the conventional FRT and the MaxTraq® 2D motion analysis. Results: The results presented that test-retest reliability of the modified digital functional reach test device was good reliability (ICC = 0.76) and low standard error of measurement (1.41) was found for test-retest reliability. The degree of agreement between the modified device, the conventional FRT, and the MaxTraq® 2D motion analysis was high (r = 0.71 and 0.77 respectively). Conclusions: The findings suggested that the modified digital functional reach test device using an ultrasonic sensor was a valid and reliable instrument for fall risk screening towards functional reach distance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical Human Kinetics
Biomedical Human Kinetics HEALTH CARE SCIENCES & SERVICES-
CiteScore
1.50
自引率
12.50%
发文量
0
审稿时长
15 weeks
期刊介绍: The leading idea is the health-directed quality of life. The journal thus covers many biomedical areas related to physical activity, e.g. physiology, biochemistry, biomechanics, anthropology, medical issues associated with physical activities, physical and motor development, psychological and sociological issues associated with physical activities, rehabilitation, health-related sport issues and fitness, etc.
期刊最新文献
Bone mineral density in the various regions of the skeleton in women with subclinical hypothyroidism: the effect of biological factors, bone turnover markers and physical activity Metabolic disturbances in sedentary and active Polish male students with normal body mass index and waist circumference Rifle and aiming point accelerations do not differ between the most and least accurate shots in biathlon shooting within an athlete Physical fitness and somatic structure in adolescent taekwondo athletes and untrained peers Epidemiology of musculoskeletal injuries in combat sports practitioners
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1