喷浇钢筋板夹套不合格钢筋混凝土扩展矩形柱的抗震性能

Muhsin Can Lüleci, Bilal Sarı, U. Demir, Muhammed Maraşlı, A. Ilki
{"title":"喷浇钢筋板夹套不合格钢筋混凝土扩展矩形柱的抗震性能","authors":"Muhsin Can Lüleci, Bilal Sarı, U. Demir, Muhammed Maraşlı, A. Ilki","doi":"10.7712/120121.8466.18708","DOIUrl":null,"url":null,"abstract":"In earthquake prone areas, columns of many relatively old RC (reinforced concrete) structures do not comply with the current seismic design codes, particularly in developing countries. Low concrete strength, improper seismic detailing of transverse reinforcement and high axial stresses on the columns are common problems causing lack of sufficient ductility under seismic forces. External jacketing of substandard columns by spraying GFRM (glass fiber re-inforced mortar) is a new, practical and feasible method to overcome these deficiencies, particularly for the cases where access to the structural members is limited. In this study, the effects of cross-sectional aspect ratio (h/b) of columns on effectiveness of external jacketing with sprayed GFRM are investigated experimentally. For this purpose, four full scale RC columns were tested under constant axial load (0.35f ’ c A g ) and cyclic lateral displacement rever-sals before and after seismic retrofit with sprayed GFRM jacket. The cross-sectional aspect ratios of two columns were 2.0, whereas the cross-sectional aspect ratio was 4.0 for the other two columns. The structural responses of the columns are discussed through hysteretic and envelope load-displacement curves. The test results show that sprayed GFRM jacketing improves lateral ductility of the substandard columns significantly. It is also shown that the method is effective for the columns with high cross-sectional aspect ratios. Keywords","PeriodicalId":66281,"journal":{"name":"地震工程与工程振动","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"SEISMIC BEHAVIOR OF SUBSTANDARD EXTENDED RECTANGULAR RC COLUMNS JACKETED WITH SPRAYED GFRM\",\"authors\":\"Muhsin Can Lüleci, Bilal Sarı, U. Demir, Muhammed Maraşlı, A. Ilki\",\"doi\":\"10.7712/120121.8466.18708\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In earthquake prone areas, columns of many relatively old RC (reinforced concrete) structures do not comply with the current seismic design codes, particularly in developing countries. Low concrete strength, improper seismic detailing of transverse reinforcement and high axial stresses on the columns are common problems causing lack of sufficient ductility under seismic forces. External jacketing of substandard columns by spraying GFRM (glass fiber re-inforced mortar) is a new, practical and feasible method to overcome these deficiencies, particularly for the cases where access to the structural members is limited. In this study, the effects of cross-sectional aspect ratio (h/b) of columns on effectiveness of external jacketing with sprayed GFRM are investigated experimentally. For this purpose, four full scale RC columns were tested under constant axial load (0.35f ’ c A g ) and cyclic lateral displacement rever-sals before and after seismic retrofit with sprayed GFRM jacket. The cross-sectional aspect ratios of two columns were 2.0, whereas the cross-sectional aspect ratio was 4.0 for the other two columns. The structural responses of the columns are discussed through hysteretic and envelope load-displacement curves. The test results show that sprayed GFRM jacketing improves lateral ductility of the substandard columns significantly. It is also shown that the method is effective for the columns with high cross-sectional aspect ratios. Keywords\",\"PeriodicalId\":66281,\"journal\":{\"name\":\"地震工程与工程振动\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"地震工程与工程振动\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.7712/120121.8466.18708\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"地震工程与工程振动","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.7712/120121.8466.18708","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在地震多发地区,许多相对较老的钢筋混凝土结构的柱不符合现行的抗震设计规范,特别是在发展中国家。混凝土强度低、横向配筋抗震配筋不当、柱上轴向应力大是地震作用下延性不足的常见问题。喷射玻璃纤维增强砂浆(GFRM)对不合格柱进行外护套是一种新的、实用的、可行的方法,可以克服这些缺陷,特别是在接近结构构件受到限制的情况下。本文通过试验研究了柱截面长径比(h/b)对喷射式玻璃钢外护套效能的影响。为此,对4根全尺寸RC柱进行了恒定轴向荷载(0.35f’c A g)试验,并对喷喷GFRM护套抗震改造前后的循环侧向位移进行了反演。其中两列的横截面纵横比为2.0,其余两列的横截面纵横比为4.0。通过滞回曲线和包络荷载-位移曲线讨论了柱的结构响应。试验结果表明,喷施GFRM护套能显著提高不合格柱的横向延性。结果表明,该方法对具有高横宽比的柱是有效的。关键字
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SEISMIC BEHAVIOR OF SUBSTANDARD EXTENDED RECTANGULAR RC COLUMNS JACKETED WITH SPRAYED GFRM
In earthquake prone areas, columns of many relatively old RC (reinforced concrete) structures do not comply with the current seismic design codes, particularly in developing countries. Low concrete strength, improper seismic detailing of transverse reinforcement and high axial stresses on the columns are common problems causing lack of sufficient ductility under seismic forces. External jacketing of substandard columns by spraying GFRM (glass fiber re-inforced mortar) is a new, practical and feasible method to overcome these deficiencies, particularly for the cases where access to the structural members is limited. In this study, the effects of cross-sectional aspect ratio (h/b) of columns on effectiveness of external jacketing with sprayed GFRM are investigated experimentally. For this purpose, four full scale RC columns were tested under constant axial load (0.35f ’ c A g ) and cyclic lateral displacement rever-sals before and after seismic retrofit with sprayed GFRM jacket. The cross-sectional aspect ratios of two columns were 2.0, whereas the cross-sectional aspect ratio was 4.0 for the other two columns. The structural responses of the columns are discussed through hysteretic and envelope load-displacement curves. The test results show that sprayed GFRM jacketing improves lateral ductility of the substandard columns significantly. It is also shown that the method is effective for the columns with high cross-sectional aspect ratios. Keywords
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
4781
期刊介绍:
期刊最新文献
GENETIC OPTIMIZATION FOR THE DESIGN OF SEISMIC RETROFITTING OF PLANE RC FRAMES WITH BUCKLING RESTRAINED BRACES (BRBS) LARGE-DISPLACEMENT RESPONSE OF UNREINFORCED MASONRY STRUCTURES: COMPARISON BETWEEN ANALYTICAL SOLUTIONS AND DEM MODELS INCLUDING OPEN-SOURCE SOFTWARE CYCLIC TESTING OF 1:40 SCALE CANTILEVER RC ELEMENTS WITH DIGITALLY MANUFACTURED REINFORCEMENT 3D ROCKING MOTION: BLIND PREDICTION CONTEST RESULTS AND INFLUENCE OF EVALUATION METRIC ON THE RANKINGS EXPERIMENTAL AND NUMERICAL INVESTIGATION OF THE PLASTIC CYCLIC BEHAVIOUR OF SIMPLE STEEL COUPONS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1