减少重复尿液药物检测的需要,灰色区域由测量不确定性决定。

IF 1.8 4区 心理学 Q4 PSYCHOLOGY, EXPERIMENTAL Perceptual and Motor Skills Pub Date : 2023-10-27 DOI:10.5937/jomb0-41777
Kagan Huysal, Yasemin Üstündağ, Hatice Azra Çağlak, Yeşil Meryem Rümeysa
{"title":"减少重复尿液药物检测的需要,灰色区域由测量不确定性决定。","authors":"Kagan Huysal, Yasemin Üstündağ, Hatice Azra Çağlak, Yeşil Meryem Rümeysa","doi":"10.5937/jomb0-41777","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>On an initial urine screening test for illegal substances, if the concentration of a substance is at or above the determined legislative threshold, it is reported as positive. Repeating testing with the same sample to verify it before reporting is a common practice in clinical laboratories. This study aimed to determine whether measurement uncertainty (MU) results can be used to detect a grey zone to reduce repeat testing.</p><p><strong>Methods: </strong>A retrospective study was conducted using data from the laboratory information system between January 1, 2020, and July 1, 2022. Samples studied twice within one hour before reporting for the same urine sample were analyzed. The MU values for urinary amphetamine, cannabinoid, cocaine, and opioid parameters were calculated using ADVIA Chemistry reagents on a Siemens ADVIA 1800 chemical analyzer. The grey zone was defined as the cut-off value ± MU.</p>","PeriodicalId":19869,"journal":{"name":"Perceptual and Motor Skills","volume":"31 1","pages":"616-620"},"PeriodicalIF":1.8000,"publicationDate":"2023-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10710810/pdf/","citationCount":"0","resultStr":"{\"title\":\"Reducing the need for repeating urine drug testing with the gray zone determined by the measurement uncertainty.\",\"authors\":\"Kagan Huysal, Yasemin Üstündağ, Hatice Azra Çağlak, Yeşil Meryem Rümeysa\",\"doi\":\"10.5937/jomb0-41777\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>On an initial urine screening test for illegal substances, if the concentration of a substance is at or above the determined legislative threshold, it is reported as positive. Repeating testing with the same sample to verify it before reporting is a common practice in clinical laboratories. This study aimed to determine whether measurement uncertainty (MU) results can be used to detect a grey zone to reduce repeat testing.</p><p><strong>Methods: </strong>A retrospective study was conducted using data from the laboratory information system between January 1, 2020, and July 1, 2022. Samples studied twice within one hour before reporting for the same urine sample were analyzed. The MU values for urinary amphetamine, cannabinoid, cocaine, and opioid parameters were calculated using ADVIA Chemistry reagents on a Siemens ADVIA 1800 chemical analyzer. The grey zone was defined as the cut-off value ± MU.</p>\",\"PeriodicalId\":19869,\"journal\":{\"name\":\"Perceptual and Motor Skills\",\"volume\":\"31 1\",\"pages\":\"616-620\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-10-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10710810/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Perceptual and Motor Skills\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5937/jomb0-41777\",\"RegionNum\":4,\"RegionCategory\":\"心理学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PSYCHOLOGY, EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Perceptual and Motor Skills","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5937/jomb0-41777","RegionNum":4,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PSYCHOLOGY, EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:在对非法药物进行初次尿液筛查检验时,如果某种药物的浓度达到或超过所确定的立法阈值,则报告为阳性。在报告前对同一样本进行重复检测以进行验证是临床实验室的常见做法。本研究旨在确定测量不确定性(MU)结果是否可用于检测灰色区域,以减少重复检测:利用实验室信息系统中 2020 年 1 月 1 日至 2022 年 7 月 1 日期间的数据进行了一项回顾性研究。对同一尿样在报告前一小时内检测两次的样本进行了分析。使用西门子ADVIA 1800化学分析仪上的ADVIA化学试剂计算尿液中苯丙胺、大麻素、可卡因和阿片参数的MU值。灰色区域定义为临界值 ± MU。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reducing the need for repeating urine drug testing with the gray zone determined by the measurement uncertainty.

Background: On an initial urine screening test for illegal substances, if the concentration of a substance is at or above the determined legislative threshold, it is reported as positive. Repeating testing with the same sample to verify it before reporting is a common practice in clinical laboratories. This study aimed to determine whether measurement uncertainty (MU) results can be used to detect a grey zone to reduce repeat testing.

Methods: A retrospective study was conducted using data from the laboratory information system between January 1, 2020, and July 1, 2022. Samples studied twice within one hour before reporting for the same urine sample were analyzed. The MU values for urinary amphetamine, cannabinoid, cocaine, and opioid parameters were calculated using ADVIA Chemistry reagents on a Siemens ADVIA 1800 chemical analyzer. The grey zone was defined as the cut-off value ± MU.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Perceptual and Motor Skills
Perceptual and Motor Skills PSYCHOLOGY, EXPERIMENTAL-
CiteScore
2.90
自引率
6.20%
发文量
110
期刊最新文献
Investigation of the Stretch-Shortening Cycle Performance of Youth Female Volleyball Players According to Different Biological Maturation and Training Status. Variety and Time in Moderate- to Vigorous-Intensity Physical Activity: Do Contextual Factors Play a Role? How Serve Tactics Shape Game Dynamics in Professional Men's Padel. Novel Clinical Assessment of Visual, Vestibular, Somatosensory, and Autonomic Function: Establishing Test Re-Test Reliability in a Healthy Population. The Acute Effects of Walking With Blood Flow Restriction on Learning of a Visuomotor Tracking Task.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1