S. Illias, S. Hussain, M. S. Ishak, Md Tasyrif Abdul Rahman, Syamsul Syahrun Awang @ Hashim, S. Selamat, M. Ani
{"title":"单液滴大小和体积测量-实验与理论的比较","authors":"S. Illias, S. Hussain, M. S. Ishak, Md Tasyrif Abdul Rahman, Syamsul Syahrun Awang @ Hashim, S. Selamat, M. Ani","doi":"10.24191/jmeche.v20i1.21093","DOIUrl":null,"url":null,"abstract":"The main objective of this paper is to conduct a manual drop test experiment to investigate the actual size and volume of a single droplet. Both experimental result and theoretical value were calculated for comparison. In this study methanol was chosen as the test liquid. The drop test was repeated numerous times with the droplet size measurement being calculated for every 50, 100 and 150 drops. A digital weight measurement was used to precisely measure the droplet weight in the drop test. Meanwhile for theoretical calculation, measurement was made based on chemical properties of the liquid itself. Based on the comparison, it was found that the experimental measurement of droplet size and volume is comparable with the theoretical calculation.","PeriodicalId":16166,"journal":{"name":"Journal of Mechanical Engineering and Sciences","volume":"13 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Single Droplet Size and Volume Measurement – Comparison Between Experiment and Theory\",\"authors\":\"S. Illias, S. Hussain, M. S. Ishak, Md Tasyrif Abdul Rahman, Syamsul Syahrun Awang @ Hashim, S. Selamat, M. Ani\",\"doi\":\"10.24191/jmeche.v20i1.21093\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main objective of this paper is to conduct a manual drop test experiment to investigate the actual size and volume of a single droplet. Both experimental result and theoretical value were calculated for comparison. In this study methanol was chosen as the test liquid. The drop test was repeated numerous times with the droplet size measurement being calculated for every 50, 100 and 150 drops. A digital weight measurement was used to precisely measure the droplet weight in the drop test. Meanwhile for theoretical calculation, measurement was made based on chemical properties of the liquid itself. Based on the comparison, it was found that the experimental measurement of droplet size and volume is comparable with the theoretical calculation.\",\"PeriodicalId\":16166,\"journal\":{\"name\":\"Journal of Mechanical Engineering and Sciences\",\"volume\":\"13 1\",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mechanical Engineering and Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24191/jmeche.v20i1.21093\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mechanical Engineering and Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24191/jmeche.v20i1.21093","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Single Droplet Size and Volume Measurement – Comparison Between Experiment and Theory
The main objective of this paper is to conduct a manual drop test experiment to investigate the actual size and volume of a single droplet. Both experimental result and theoretical value were calculated for comparison. In this study methanol was chosen as the test liquid. The drop test was repeated numerous times with the droplet size measurement being calculated for every 50, 100 and 150 drops. A digital weight measurement was used to precisely measure the droplet weight in the drop test. Meanwhile for theoretical calculation, measurement was made based on chemical properties of the liquid itself. Based on the comparison, it was found that the experimental measurement of droplet size and volume is comparable with the theoretical calculation.
期刊介绍:
The Journal of Mechanical Engineering & Sciences "JMES" (ISSN (Print): 2289-4659; e-ISSN: 2231-8380) is an open access peer-review journal (Indexed by Emerging Source Citation Index (ESCI), WOS; SCOPUS Index (Elsevier); EBSCOhost; Index Copernicus; Ulrichsweb, DOAJ, Google Scholar) which publishes original and review articles that advance the understanding of both the fundamentals of engineering science and its application to the solution of challenges and problems in mechanical engineering systems, machines and components. It is particularly concerned with the demonstration of engineering science solutions to specific industrial problems. Original contributions providing insight into the use of analytical, computational modeling, structural mechanics, metal forming, behavior and application of advanced materials, impact mechanics, strain localization and other effects of nonlinearity, fluid mechanics, robotics, tribology, thermodynamics, and materials processing generally from the core of the journal contents are encouraged. Only original, innovative and novel papers will be considered for publication in the JMES. The authors are required to confirm that their paper has not been submitted to any other journal in English or any other language. The JMES welcome contributions from all who wishes to report on new developments and latest findings in mechanical engineering.