O. Kolosov, F. Dinelli, A. Robson, A. Krier, M. Hayne, V. Fal’ko, M. Henini
{"title":"从几纳米到亚微米深度的半导体结构的纳米尺度三维纳米力学成像","authors":"O. Kolosov, F. Dinelli, A. Robson, A. Krier, M. Hayne, V. Fal’ko, M. Henini","doi":"10.1109/IITC-MAM.2015.7325609","DOIUrl":null,"url":null,"abstract":"Multilayer structures of active semiconductor devices (1), novel memories (2) and semiconductor interconnects are becoming increasingly three-dimensional (3D) with simultaneous decrease of dimensions down to the few nanometres length scale (3). Ability to test and explore these 3D nanostructures with nanoscale resolution is vital for the optimization of their operation and improving manufacturing processes of new semiconductor devices. While electron and scanning probe microscopes (SPMs) can provide necessary lateral resolution, their ability to probe underneath the immediate surface is severely limited. Cross-sectioning of the structures via focused ion beam (FIB) to expose the subsurface areas often introduces multiple artefacts that mask the true features of the hidden structures, negating benefits of such approach. In addition, the few tens of micrometre dimension of FIB cut, make it unusable for the SPM investigation.","PeriodicalId":6514,"journal":{"name":"2015 IEEE International Interconnect Technology Conference and 2015 IEEE Materials for Advanced Metallization Conference (IITC/MAM)","volume":"17 1","pages":"43-46"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Nanometre scale 3D nanomechanical imaging of semiconductor structures from few nm to sub-micrometre depths\",\"authors\":\"O. Kolosov, F. Dinelli, A. Robson, A. Krier, M. Hayne, V. Fal’ko, M. Henini\",\"doi\":\"10.1109/IITC-MAM.2015.7325609\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multilayer structures of active semiconductor devices (1), novel memories (2) and semiconductor interconnects are becoming increasingly three-dimensional (3D) with simultaneous decrease of dimensions down to the few nanometres length scale (3). Ability to test and explore these 3D nanostructures with nanoscale resolution is vital for the optimization of their operation and improving manufacturing processes of new semiconductor devices. While electron and scanning probe microscopes (SPMs) can provide necessary lateral resolution, their ability to probe underneath the immediate surface is severely limited. Cross-sectioning of the structures via focused ion beam (FIB) to expose the subsurface areas often introduces multiple artefacts that mask the true features of the hidden structures, negating benefits of such approach. In addition, the few tens of micrometre dimension of FIB cut, make it unusable for the SPM investigation.\",\"PeriodicalId\":6514,\"journal\":{\"name\":\"2015 IEEE International Interconnect Technology Conference and 2015 IEEE Materials for Advanced Metallization Conference (IITC/MAM)\",\"volume\":\"17 1\",\"pages\":\"43-46\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Interconnect Technology Conference and 2015 IEEE Materials for Advanced Metallization Conference (IITC/MAM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IITC-MAM.2015.7325609\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Interconnect Technology Conference and 2015 IEEE Materials for Advanced Metallization Conference (IITC/MAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IITC-MAM.2015.7325609","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Nanometre scale 3D nanomechanical imaging of semiconductor structures from few nm to sub-micrometre depths
Multilayer structures of active semiconductor devices (1), novel memories (2) and semiconductor interconnects are becoming increasingly three-dimensional (3D) with simultaneous decrease of dimensions down to the few nanometres length scale (3). Ability to test and explore these 3D nanostructures with nanoscale resolution is vital for the optimization of their operation and improving manufacturing processes of new semiconductor devices. While electron and scanning probe microscopes (SPMs) can provide necessary lateral resolution, their ability to probe underneath the immediate surface is severely limited. Cross-sectioning of the structures via focused ion beam (FIB) to expose the subsurface areas often introduces multiple artefacts that mask the true features of the hidden structures, negating benefits of such approach. In addition, the few tens of micrometre dimension of FIB cut, make it unusable for the SPM investigation.