Qiuyang Tao, Minghui Wei, Hongjun Chen, Aihua Deng, Yilin He
{"title":"井下仪表蒸汽压缩热管理系统","authors":"Qiuyang Tao, Minghui Wei, Hongjun Chen, Aihua Deng, Yilin He","doi":"10.1115/1.4062555","DOIUrl":null,"url":null,"abstract":"\n As the depth of oil and gas exploration increases, downhole electronics face the threat of high temperature failure. At present, passive cooling technology has the problem of short working time, while active cooling technology has low energy utilization. This paper presents a thermal management system of vapor compression with a combination of active and passive cooling. The system uses insulation materials to isolate the high-temperature environment, thermally conductive silicone grease to strengthen the heat exchange in the evaporator, and vapor compression refrigeration cycles to absorb internal heat.The coefficient of performance (COP), exergy destruction and exergy efficiency of octane, nonane and cyclohexane as refrigerants were examined, and the effects of different insulation materials on refrigeration performance were studied from both theoretical and numerical perspectives. The results showed that cyclohexane exhibited the best cooling capacity with a COP of 1.296 and a exergy efficiency of 49.21%. The thermal management system cooling performance is optimal when the insulation material is a vacuum flask, with an effective cooling capacity of 121.7W.","PeriodicalId":17404,"journal":{"name":"Journal of Thermal Science and Engineering Applications","volume":"34 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2023-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal management system of vapor compression for downhole instrument\",\"authors\":\"Qiuyang Tao, Minghui Wei, Hongjun Chen, Aihua Deng, Yilin He\",\"doi\":\"10.1115/1.4062555\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n As the depth of oil and gas exploration increases, downhole electronics face the threat of high temperature failure. At present, passive cooling technology has the problem of short working time, while active cooling technology has low energy utilization. This paper presents a thermal management system of vapor compression with a combination of active and passive cooling. The system uses insulation materials to isolate the high-temperature environment, thermally conductive silicone grease to strengthen the heat exchange in the evaporator, and vapor compression refrigeration cycles to absorb internal heat.The coefficient of performance (COP), exergy destruction and exergy efficiency of octane, nonane and cyclohexane as refrigerants were examined, and the effects of different insulation materials on refrigeration performance were studied from both theoretical and numerical perspectives. The results showed that cyclohexane exhibited the best cooling capacity with a COP of 1.296 and a exergy efficiency of 49.21%. The thermal management system cooling performance is optimal when the insulation material is a vacuum flask, with an effective cooling capacity of 121.7W.\",\"PeriodicalId\":17404,\"journal\":{\"name\":\"Journal of Thermal Science and Engineering Applications\",\"volume\":\"34 1\",\"pages\":\"\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Thermal Science and Engineering Applications\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4062555\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Science and Engineering Applications","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4062555","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Thermal management system of vapor compression for downhole instrument
As the depth of oil and gas exploration increases, downhole electronics face the threat of high temperature failure. At present, passive cooling technology has the problem of short working time, while active cooling technology has low energy utilization. This paper presents a thermal management system of vapor compression with a combination of active and passive cooling. The system uses insulation materials to isolate the high-temperature environment, thermally conductive silicone grease to strengthen the heat exchange in the evaporator, and vapor compression refrigeration cycles to absorb internal heat.The coefficient of performance (COP), exergy destruction and exergy efficiency of octane, nonane and cyclohexane as refrigerants were examined, and the effects of different insulation materials on refrigeration performance were studied from both theoretical and numerical perspectives. The results showed that cyclohexane exhibited the best cooling capacity with a COP of 1.296 and a exergy efficiency of 49.21%. The thermal management system cooling performance is optimal when the insulation material is a vacuum flask, with an effective cooling capacity of 121.7W.
期刊介绍:
Applications in: Aerospace systems; Gas turbines; Biotechnology; Defense systems; Electronic and photonic equipment; Energy systems; Manufacturing; Refrigeration and air conditioning; Homeland security systems; Micro- and nanoscale devices; Petrochemical processing; Medical systems; Energy efficiency; Sustainability; Solar systems; Combustion systems