R. Jiang, Qi-ming Wu, Y. Xiao, M. Peng, Tianhua Xu
{"title":"波纹钢腹板组合箱梁桥剪切滞后效应的估算","authors":"R. Jiang, Qi-ming Wu, Y. Xiao, M. Peng, Tianhua Xu","doi":"10.4172/2165-784X.1000319","DOIUrl":null,"url":null,"abstract":"The shear-lag effect refers to the non-uniform normal stress distribution on a box girder cross section induced by the shear flow at the flanges and the webs. It can be observed in all kinds of box girder structures especially the ones with a large width. The shear-lag effect has to be appropriately considered in bridge design, otherwise the servicability and reliability of a bridge will be reduced. In this paper, a semi-analytical method is proposed to estimate the shear-lag effect for composite box girder bridges with corrugated steel webs. Three generalized displacement functions are first introduced to represent the deformation patterns in different parts of a bridge cross section. Afterwards, the governing equations of the problem are derived based on the energy variance principle considering the feature of a composite box girder bridge with corurgated steel webs and then solved using the finite difference method. The shear-lag effect of a continuous girder bridge constructed in South China is investigated based on the proposed semi-analytical method and finite element simulation. The results show that the proposed semi-analytical method is able to well estimate the characteristics of the example bridge. Given the same bridge cross section, the magnitude of the shear-lag effect at different parts of the example bridge is inversely proportional to the effective span length.","PeriodicalId":52256,"journal":{"name":"Tumu yu Huanjing Gongcheng Xuebao/Journal of Civil and Environmental Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Estimation of The Shear-Lag Effect of Composite Box Girder Bridges With Corrugated Steel Webs\",\"authors\":\"R. Jiang, Qi-ming Wu, Y. Xiao, M. Peng, Tianhua Xu\",\"doi\":\"10.4172/2165-784X.1000319\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The shear-lag effect refers to the non-uniform normal stress distribution on a box girder cross section induced by the shear flow at the flanges and the webs. It can be observed in all kinds of box girder structures especially the ones with a large width. The shear-lag effect has to be appropriately considered in bridge design, otherwise the servicability and reliability of a bridge will be reduced. In this paper, a semi-analytical method is proposed to estimate the shear-lag effect for composite box girder bridges with corrugated steel webs. Three generalized displacement functions are first introduced to represent the deformation patterns in different parts of a bridge cross section. Afterwards, the governing equations of the problem are derived based on the energy variance principle considering the feature of a composite box girder bridge with corurgated steel webs and then solved using the finite difference method. The shear-lag effect of a continuous girder bridge constructed in South China is investigated based on the proposed semi-analytical method and finite element simulation. The results show that the proposed semi-analytical method is able to well estimate the characteristics of the example bridge. Given the same bridge cross section, the magnitude of the shear-lag effect at different parts of the example bridge is inversely proportional to the effective span length.\",\"PeriodicalId\":52256,\"journal\":{\"name\":\"Tumu yu Huanjing Gongcheng Xuebao/Journal of Civil and Environmental Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tumu yu Huanjing Gongcheng Xuebao/Journal of Civil and Environmental Engineering\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.4172/2165-784X.1000319\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tumu yu Huanjing Gongcheng Xuebao/Journal of Civil and Environmental Engineering","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.4172/2165-784X.1000319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
Estimation of The Shear-Lag Effect of Composite Box Girder Bridges With Corrugated Steel Webs
The shear-lag effect refers to the non-uniform normal stress distribution on a box girder cross section induced by the shear flow at the flanges and the webs. It can be observed in all kinds of box girder structures especially the ones with a large width. The shear-lag effect has to be appropriately considered in bridge design, otherwise the servicability and reliability of a bridge will be reduced. In this paper, a semi-analytical method is proposed to estimate the shear-lag effect for composite box girder bridges with corrugated steel webs. Three generalized displacement functions are first introduced to represent the deformation patterns in different parts of a bridge cross section. Afterwards, the governing equations of the problem are derived based on the energy variance principle considering the feature of a composite box girder bridge with corurgated steel webs and then solved using the finite difference method. The shear-lag effect of a continuous girder bridge constructed in South China is investigated based on the proposed semi-analytical method and finite element simulation. The results show that the proposed semi-analytical method is able to well estimate the characteristics of the example bridge. Given the same bridge cross section, the magnitude of the shear-lag effect at different parts of the example bridge is inversely proportional to the effective span length.