CFRP钢结构组件的弹塑性准静态及冲击荷载响应

Ali Al Aloosi, Zia Razzaq
{"title":"CFRP钢结构组件的弹塑性准静态及冲击荷载响应","authors":"Ali Al Aloosi, Zia Razzaq","doi":"10.24018/ejeng.2023.8.2.2968","DOIUrl":null,"url":null,"abstract":"Presented in this paper is the outcome of an experimental investigation of the elastoplastic quasi-static and impact load response of a steel sub-assemblage constructed using a pair of hollow square section members with or without Carbon Fiber Reinforced Polymer (CFRP) strips. The sub-assemblage consists of a long structural member welded to a short member, thus representing a typical combination of a column and a beam on the face of a multi-story steel building frame. The column is subjected to a lateral quasi-static or impact load. Tests are conducted on four separate steel sub-assemblages. The first two tests are conducted with a gradually increasing flexural load applied at the midspan of the column up to the collapse condition without and with CFRP strips, respectively. Additional two tests are performed with a flexural impact load applied at midspan of the column also both without and with CFRP strips, respectively. The results of the study show that CFRP strips substantially increase the quasi-static collapse load of the sub-assemblage. However, when subjected to an impact load, the steel structure sub-assemblage with CFRP strips developed smaller strains in comparison with those without the CFRP strips. The post-impact time-dependent strains also became considerably smaller for the sub-assemblage with CFRP strips.","PeriodicalId":12001,"journal":{"name":"European Journal of Engineering and Technology Research","volume":"33 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Elastoplastic Quasi-Static and Impact Load Response of Steel Structure Sub-Assemblage with CFRP Strips\",\"authors\":\"Ali Al Aloosi, Zia Razzaq\",\"doi\":\"10.24018/ejeng.2023.8.2.2968\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Presented in this paper is the outcome of an experimental investigation of the elastoplastic quasi-static and impact load response of a steel sub-assemblage constructed using a pair of hollow square section members with or without Carbon Fiber Reinforced Polymer (CFRP) strips. The sub-assemblage consists of a long structural member welded to a short member, thus representing a typical combination of a column and a beam on the face of a multi-story steel building frame. The column is subjected to a lateral quasi-static or impact load. Tests are conducted on four separate steel sub-assemblages. The first two tests are conducted with a gradually increasing flexural load applied at the midspan of the column up to the collapse condition without and with CFRP strips, respectively. Additional two tests are performed with a flexural impact load applied at midspan of the column also both without and with CFRP strips, respectively. The results of the study show that CFRP strips substantially increase the quasi-static collapse load of the sub-assemblage. However, when subjected to an impact load, the steel structure sub-assemblage with CFRP strips developed smaller strains in comparison with those without the CFRP strips. The post-impact time-dependent strains also became considerably smaller for the sub-assemblage with CFRP strips.\",\"PeriodicalId\":12001,\"journal\":{\"name\":\"European Journal of Engineering and Technology Research\",\"volume\":\"33 3\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Engineering and Technology Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24018/ejeng.2023.8.2.2968\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Engineering and Technology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24018/ejeng.2023.8.2.2968","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了用一对空心方截面构件(含或不含碳纤维增强聚合物(CFRP)条)构建的钢构件的弹塑性准静态和冲击载荷响应的实验研究结果。子组件由一个长构件焊接到一个短构件组成,因此代表了多层钢结构框架表面的柱和梁的典型组合。柱承受横向准静态或冲击载荷。试验在四个独立的钢组件上进行。前两项试验分别在柱跨中施加逐渐增加的弯曲载荷直至倒塌条件下进行,不使用和使用CFRP条。另外两项试验分别在柱的跨中施加了弯曲冲击载荷,包括不带和带CFRP条的试验。研究结果表明,碳纤维布条显著增加了子组合的准静态破坏荷载。然而,在冲击荷载作用下,安装碳纤维布的钢结构构件比未安装碳纤维布的钢结构构件产生更小的应变。撞击后随时间变化的应变对于CFRP条的子组合也变得相当小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Elastoplastic Quasi-Static and Impact Load Response of Steel Structure Sub-Assemblage with CFRP Strips
Presented in this paper is the outcome of an experimental investigation of the elastoplastic quasi-static and impact load response of a steel sub-assemblage constructed using a pair of hollow square section members with or without Carbon Fiber Reinforced Polymer (CFRP) strips. The sub-assemblage consists of a long structural member welded to a short member, thus representing a typical combination of a column and a beam on the face of a multi-story steel building frame. The column is subjected to a lateral quasi-static or impact load. Tests are conducted on four separate steel sub-assemblages. The first two tests are conducted with a gradually increasing flexural load applied at the midspan of the column up to the collapse condition without and with CFRP strips, respectively. Additional two tests are performed with a flexural impact load applied at midspan of the column also both without and with CFRP strips, respectively. The results of the study show that CFRP strips substantially increase the quasi-static collapse load of the sub-assemblage. However, when subjected to an impact load, the steel structure sub-assemblage with CFRP strips developed smaller strains in comparison with those without the CFRP strips. The post-impact time-dependent strains also became considerably smaller for the sub-assemblage with CFRP strips.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Transitioning from “Grey to Green”: Nature-Based Solution Seawall for Coastal Protection Effectiveness of Suspended Lead Dampers in Steel Building Structural Model Subjected to Impact Load Effective Use of Catastrophe Multicriteria Decision Analysis in Delineating Groundwater Recharge Potential Zones Design of an Energy Efficient Buck Based LED Driver in DCM and CCM Visualization of Chladni Patterns at Low-Frequency Resonant and Non-Resonant Flexural Modes of Vibration
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1